Showing 10189–10197 of 10209 results

  • Yokogawa CL250

    $235

    Yokogawa Model # CL250 Method of detection True RMS Display LCD(Digital display:3999 counts) Response Time Approx. 2 seconds Range Switching Auto-range Data Hold On all range Peak Hold On AC/DC current range, AC/DC voltage range Ambient temperature and humidity 0 to 40 deg.C, 90% RH or less (no condensation) Influence of conductor position ±2.0% or less Safety Standard Conforms EN61010-1, EN61010-2-031, EN61010-2-032 Circuit Voltage 600Vrms or less Withstanding Voltage 5.55kV AC for one minute Power Supply 6F22(006P)9V ×1 or 6LR61 ×1 Battery Life Approx. 15 hours (continuous) Consumed Current Approx. 15mA Sleep Function Automatically powered down in about 30 minutes after the last switch operation Diameter of measurable conductor 33mm at maximum Dimensions Approx.91(W) × 210(H) × 40(D)mm Weight Approx. 450g > Each Unit Includes Users manual (IM CL250) Batteries Carrying case (93034)

  • Yokogawa CL255

    $235

    CL200 series has basic function of AC/DC current measurement. These clamps allow you to measure current range from 40mA to 2000A. Choose your desired diameter of measurable conductor from 24mm to 55mm. Yokogawa Model # CL255 AC/DC current measurements with current ranges up to 2000A. True RMS display DC output 55mm in diameter of measurable conductor Sleep function Data hold function Approved for comformity to safety standards EN61010-1, EN61010-2-031, EN61010-2-032 (CAT. III 600 V, CAT. II 1000 V) /Hz

  • Yokogawa CL320

    $199

    Leakage current measurement with current range from 20mA to 200A Light weight and compact design Manual range switching and auto power-off functions 24mm in diameter of measurable conductor Mean value display Auto power-off Manual range switching Approved for comformity to safety standards EN61010-1, EN61010-2-032(CAT. III 300 V) Method of detection Mean Value Display LCD (Digital display: 1999 counts) Response Time Approx. 2 seconds Range Switching Manual-range Data hold On all range Operating temperature and humidity 0 40°C, 85% RH or less (no condensation) Influence of external magnetic field 10 mA or less in proximity to a 14.4 mm-dia conductor carrying 100A Influence of conductor position Within 5 dgt for 0 to 50A, or 2% for 50 to 200A (10 mm-dia conductor at inside the jaw) Influence of Residual Current 10 mA or less in proximity to a 10 mm-dia conductor carrying 50A Safety Standard Conforms EN61010-1, EN61010-2-032 Circuit voltage 300 Vrms or less Withstanding voltage 3.7 kV AC for one minute Power Supply LR-44 x 2(3V) SR-44 x 2 Battery Life Approx. 15 hours (continuous) Consumed current Approx. 5 mA Auto power-off Approx. 10 minutes Diameter of measurable conductor 24 mm at maximum Dimensions Approx. 60 (W) x 149 (H) x 26 (D) mm Weight Approx. 120 g > Each Unit Includes Batteries Carrying case Users manual

  • Yokogawa CL340

    $167

    Method of detection Mean value Display LCD(Digital display:3999 counts) Response Time Approx. 2 seconds Range Switching Manual-range Data Hold On all range Peak Hold On all range Ambient temperature and humidity 0 to 40 deg.C, 85% RH or less (no condensation) Temperature Coefficient Influence of external magnetic field 10mA or less in proximity to a 15mm-dia conductor carrying 100A Influence of conductor position 40/400mA range:Within 5dgt at every part inside the jaw400A range 0 to 250A:Within ±0.5%rdg ±5dgt at every part inside the jaw section Influence of residual current 12mA or less in proximity to a 10mm-dia conductor carrying 100A Safety Standard Conforms EN 61010-1, EN61010-2-032 Circuit Voltage 300Vrms or less Withstanding Voltage 3.7kV AC for one minute Power Supply R0-3(UM-4) × 2 or LR03 × 2 Battery Life Approx. 40 hours (continuous) Consumed Current Approx. 13mA Auto power-off Approx. 10 minutes Diameter of measurable conductor 40mm at maximum Dimensions Approx. 81(W) × 185(H) × 40(D)mm Weight Approx. 270g > Each Unit Includes Users manual (IM CL340) Batteries Carrying case (93030)

  • Yokogawa CL345

    $244

    True RMS display Auto power-off Manual range switching Approved for comformity to safety standards EN61010-1 (CAT. III 300 V) 40mm in diameter of measurable conductor > Each Unit Includes Users Manual Batteries Carrying Case (93030)

  • Yokogawa CL420

    $346

    0.2% Accuracy and 0.01 mA Resolution from 0-20 mA DC mA Measurement and % of Span for 4-20 mA Dual LCD Numeric Display. LED Torch Light Data Hold Function 6mm Clamp Diameter Analog Output Available Display 4-digit LCD Numeric display Response time Approx. 1.5 seconds (2.5 seconds when across the range) Range switching Auto range Operating temperature and humidity -10°C to 50°C 80% RH or less (no condensation) Safety Standards EN61010-1, EN61010-2-030, EN61010-2-032 Withstanding voltage 2.21kV AC for 5 seconds (between the core and the case) Power supply Four AA-size alkaline batteries (1.5V LR6) Battery life Approx. 60hrs (continuous) backlight off and LED light off Other functions Data hold, Zero adjust function, Auto power off, LED Torch light, Back light display, Illuminant panel External dimensions and weight 61 (W) Î 111 (H) Î 40 (D) mm Approx. 290g (including batteries) > Each Unit Includes User’s Manual Batteries Soft case

  • Yokogawa CW10

    $142

    Basic functionality of a clamp-on tester, digital multimeter and power monitor into one tool Current and voltage measurement rating is 600 A AC/DC and 1000 V AC/DC respectively with power measurement ratings upto 600 kW AC/DC Measures AC and DC Current, AC and DC Volts, Power, Power Factor, Total Harmonics Distortion & Individual Harmonics (fundamental wave to 25th), Resistance and Frequency True RMS measurement 9999 Count with White Backlit LED and Bar Graph Display Phase Rotation Voltage Detection Easy Operation with Joystick Auto Power Off Continuity Beeper CAT IV 600 V, CAT III 1000 V Safety Rating > Each Unit Includes Test leads Carrying case User’s manual Battery

  • Yokogawa MT220-100PSIG-GPIB

    $5.814

    /- 100PSIG GPIB High accuracy: 0.01% of reading 0.005% of full scale Measurement with DCV and DCA 24 V DC output Percent reading Error reading Measurement data memory D/A conversion output, comparator output, and external trigger input (optional) GP-IB or RS-232 interfaces 12 V DC power supply Battery operation (optional)

  • Yokogawa MT220-100PSIG-RS232

    $5.814

    /- 100PSIG RS232 High accuracy: 0.01% of reading 0.005% of full scale Measurement with DCV and DCA 24 V DC output Percent reading Error reading Measurement data memory D/A conversion output, comparator output, and external trigger input (optional) GP-IB or RS-232 interfaces 12 V DC power supply Battery operation (optional)