Showing 1–9 of 10 results
-
$992
Field Metrology Well, 33 °C to 350 °C, w/9143-INSX, w/Process Electronics Temperature Range at 23 °C: 33 °C to 350 °C (91 °F to 662 °F) Display Accuracy: ± 0.2 °C Full Range Stability: ± 0.02 °C at 33 °C ± 0.02 °C at 200 °C ± 0.03 °C at 350 °C Axial Uniformity at 40 mm (1.6 in): ± 0.04 °C at 33 °C ± 0.1 °C at 200 °C ± 0.2 °C at 350 °C Radial Uniformity: ± 0.01 °C at 33 °C ± 0.015 °C at 200 °C ± 0.02 °C at 350 °C Loading Effect (with a 6.35 mm reference probe and three 6.35 mm probes): ± 0.015 °C Full Range Hysteresis: 0.03°C Operating Conditions: 0 °C to 50 °C, 0 % to 90 % RH (non-condensing) Environmental Conditions (for all specifications except temperature range): 13 °C to 33 °C Immersion (Well) Depth: 150 mm (5.9 in) Insert OD: 25.3mm (1.00 in) Heating Time: 5 min: 33 °C to 350 °C Cooling Time: 32 min: 350 °C to 33 °C 14 min: 350 °C to 100 °C Resolution: 0.01 ° Display: LCD, °C or °F user-selectable Size (H x W x D): 290 mm x 185 mm x 295 mm (11.4 x 7.3 x 11.6 in) Weight: 7.3 kg (16 lb) The process version provides a built-in two-channel thermometer readout that measures PRTs, RTDs, thermocouples, and 4-20 mA transmitters which includes the 24 V loop supply to power the transmitter. > Each Unit Includes Insert B RS-232 and 9930 Interface-it control software Test Leads
-
$992
Field Metrology Well, 33 °C to 350 °C, w/9143-INSX Temperature Range at 23 °C: 33 °C to 350 °C (91 °F to 662 °F) Display Accuracy: ± 0.2 °C Full Range Stability: ± 0.02 °C at 33 °C ± 0.02 °C at 200 °C ± 0.03 °C at 350 °C Axial Uniformity at 40 mm (1.6 in): ± 0.04 °C at 33 °C ± 0.1 °C at 200 °C ± 0.2 °C at 350 °C Radial Uniformity: ± 0.01 °C at 33 °C ± 0.015 °C at 200 °C ± 0.02 °C at 350 °C Loading Effect (with a 6.35 mm reference probe and three 6.35 mm probes): ± 0.015 °C Full Range Hysteresis: 0.03°C Operating Conditions: 0 °C to 50 °C, 0 % to 90 % RH (non-condensing) Environmental Conditions (for all specifications except temperature range): 13 °C to 33 °C Immersion (Well) Depth: 150 mm (5.9 in) Insert OD: 25.3mm (1.00 in) Heating Time: 5 min: 33 °C to 350 °C Cooling Time: 32 min: 350 °C to 33 °C 14 min: 350 °C to 100 °C Resolution: 0.01 ° Display: LCD, °C or °F user-selectable Size (H x W x D): 290 mm x 185 mm x 295 mm (11.4 x 7.3 x 11.6 in) Weight: 7.3 kg (16 lb) > Each Unit Includes Insert C RS-232 and 9930 Interface-it control software
-
$992
Field Metrology Well, 33 °C to 350 °C, w/9143-INSX, w/Process Electronics Temperature Range at 23 °C: 33 °C to 350 °C (91 °F to 662 °F) Display Accuracy: ± 0.2 °C Full Range Stability: ± 0.02 °C at 33 °C ± 0.02 °C at 200 °C ± 0.03 °C at 350 °C Axial Uniformity at 40 mm (1.6 in): ± 0.04 °C at 33 °C ± 0.1 °C at 200 °C ± 0.2 °C at 350 °C Radial Uniformity: ± 0.01 °C at 33 °C ± 0.015 °C at 200 °C ± 0.02 °C at 350 °C Loading Effect (with a 6.35 mm reference probe and three 6.35 mm probes): ± 0.015 °C Full Range Hysteresis: 0.03°C Operating Conditions: 0 °C to 50 °C, 0 % to 90 % RH (non-condensing) Environmental Conditions (for all specifications except temperature range): 13 °C to 33 °C Immersion (Well) Depth: 150 mm (5.9 in) Insert OD: 25.3mm (1.00 in) Heating Time: 5 min: 33 °C to 350 °C Cooling Time: 32 min: 350 °C to 33 °C 14 min: 350 °C to 100 °C Resolution: 0.01 ° Display: LCD, °C or °F user-selectable Size (H x W x D): 290 mm x 185 mm x 295 mm (11.4 x 7.3 x 11.6 in) Weight: 7.3 kg (16 lb) The process version provides a built-in two-channel thermometer readout that measures PRTs, RTDs, thermocouples, and 4-20 mA transmitters which includes the 24 V loop supply to power the transmitter. > Each Unit Includes Insert C RS-232 and 9930 Interface-it control software Test Leads
-
$909
The Hart 9143-X is equipped with a large, easy-to-read LCD display, function keys, and menu navigation buttons New control technology guarantees excellent performance in extreme environmental conditions The Hart 9143 is stable from ± 0.02 °C at 33 °C and ± 0.03 °C at 350 °C Lightweight, portable, and fast Built-in two-channel readout for PRT, RTD, thermocouple, 4-20 mA current True reference thermometry with accuracy to ±0.01 °C On-board automation and documentation Metrology performance in accuracy, stability, uniformity, and loading Display accuracy of ± 0.2 °C over full range Heating Time: 5 min: 33 °C to 350 °C Cooling Time: 32 min: 350 °C to 33 °C, 14 min: 350 °C to 100 °C Immersion (Well) Depth: 150 mm (5.9 in) Insert OD: 25.3 mm (1.00 in) Size (H x W x D) 290 x 185 x 295mm Weight: 7.3 kg (16 lb) Hart Scientific 9143-X Warranty: 1 year > Each Unit Includes Hart 9143 Users Manual Technical Manual on CD Serial Cable 9930 Interface-it Software Report of Calibration Insert Removal Tool
-
$992
Lightweight, portable, and fast Cool to -25 °C in 15 minutes and heat to 660 °C in 15 minutes Built-in two-channel readout for PRT, RTD, thermocouple, 4-20 mA current True reference thermometry with accuracy to ± 0.01 °C On-board automation and documentation Metrology performance in accuracy, stability, uniformity, and loading > Each Unit Includes Insert E RS-232 and 9930 Interface-it control software
-
$878
Lightweight, portable, and fast Cool to -25 °C in 15 minutes and heat to 660 °C in 15 minutes Built-in two-channel readout for PRT, RTD, thermocouple, 4-20 mA current True reference thermometry with accuracy to ± 0.01 °C On-board automation and documentation Metrology performance in accuracy, stability, uniformity, and loading > Each Unit Includes Insert E RS-232 and 9930 Interface-it control software
-
$909
Lightweight, portable, and fast Cool to -25 °C in 15 minutes and heat to 660 °C in 15 minutes Built-in two-channel readout for PRT, RTD, thermocouple, 4-20 mA current True reference thermometry with accuracy to ± 0.01 °C On-board automation and documentation Metrology performance in accuracy, stability, uniformity, and loading > Each Unit Includes Insert E RS-232 and 9930 Interface-it control software
-
$1.078
Temperature Range: 150 °C to 1200 °C (302 °F to 2192 °F) Display Resolution: 0.1 ° to 999.9 ° 1 ° above 1000 ° Stability: ±0.5 °C Display Accuracy: ±5 °C Well Diameter: 1.25 (32 mm) Well Depth: 140 mm (5.5 in), (101 mm [4 in] removable insert plus 38 mm [1.5 in]insulator) Heating Time: 35 minutes to 1200 °C Cooling Time: 140 minutes with block Well-to-Well Uniformity: ±0.5 °C to ±1.0 °C (Insert “C” at 1200 °C) Stabilization: 20 minutes Weight: 28lb (13kg) NIST-Traceable Calibration: Data at 150 °C, 300 °C, 450 °C, 600 °C, 800 °C, 1000° C, and 1200 °C > Each Unit Includes 3150-2 Insert Nist Traceable Certificate
-
$1.042
Temperature Range: 150 °C to 1200 °C (302 °F to 2192 °F) Display Resolution: 0.1 ° to 999.9 ° 1 ° above 1000 ° Stability: ±0.5 °C Display Accuracy: ±5 °C Well Diameter: 1.25 (32 mm) Well Depth: 140 mm (5.5 in), (101 mm [4 in] removable insert plus 38 mm [1.5 in]insulator) Heating Time: 35 minutes to 1200 °C Cooling Time: 140 minutes with block Well-to-Well Uniformity: ±0.5 °C to ±1.0 °C (Insert “C” at 1200 °C) Stabilization: 20 minutes Weight: 28lb (13kg) NIST-Traceable Calibration: Data at 150 °C, 300 °C, 450 °C, 600 °C, 800 °C, 1000° C, and 1200 °C > Each Unit Includes 3150-3 Insert Nist Traceable Certificate