Showing 1–9 of 1705 results

  • Accutron ACC-COMMTRAX-01

    $402

    Software Features Powerful web-based interface to see site conditions anywhere, any time LiveScript, micro php Accutron Discovery Technology Real-time register polling Remote and local firmware upgrades and diagnostics with SD card Simple integration with existing fault management process and management software Datalogger with 2GB > Protocols TCP/IP, HTML, TFTP SNMP Modbus (RS485): Modbus Master/Slave, RTU mode Modbus TCP/IP: Modbus Master/Slave, TCP/IP transmission protocol Modbus RTU RS-485 Modbus TCP over Ethernet 10/100Base > Benefits Can communicate with multiple Modbus devices via multiple Modbus interfaces Provides a multitude of monitoring applications in one simple and reliable integrated solution Simple way to transmit I/O data between modbus RTU and Modbus TCP Din-rail mountable Simple CSV data logging Modbus register consolidation >

  • Accutron ACC-IOTRAX-01

    $402

    Remote network diagnostics Line fault monitoring and LED status display per channel Four analog 4-20 mA isolated inputs Four digital inputs, optically isolated Two relay alarm outputs Direct connectivity to industrial sensors and actuators Modbus RS485 communication with two alarm relays Din-rail Modular design Accutron LiveScript Technology, our web-based app for easy and quick configuration Ultra-compact design for application where a typical PLC or I/O solution simply would not fit Isolated 4-20 mA inputs Discrete digital I/O Quick snap connections LED indicators Built-in Modbus RTU, Modbus ASCII Three bus couplers use Ethernet, Modbus TCP, Profibus protocols Modbus Slave 2 x Relay Outputs 4 x Analog Inputs (isolated) 4 x Digital Inputs >

  • Accutron ACC-IOTRAX-02

    $402

    Remote network diagnostics Line fault monitoring and LED status display per channel Four analog 4-20 mA isolated inputs Four digital inputs, optically isolated Two relay alarm outputs Direct connectivity to industrial sensors and actuators Modbus RS485 communication with two alarm relays Din-rail Modular design Accutron LiveScript Technology, our web-based app for easy and quick configuration Ultra-compact design for application where a typical PLC or I/O solution simply would not fit Isolated 4-20 mA inputs Discrete digital I/O Quick snap connections LED indicators Built-in Modbus RTU, Modbus ASCII Three bus couplers use Ethernet, Modbus TCP, Profibus protocols Modbus Slave 4 x Open Collector digital outputs 4 x Analog outputs 4 x Digital Inputs >

  • Ametek Jofra ASM801BXXX

    $2.155

    Advanced Signal Multi-Scanner Universal Screw Plugs, Circuit Order #: ASM801BXXX Mfg #: ASM801BXXX

  • Cole-Parmer EW-32908-79

    $1.236

    These meters measure flow via pressure drop across a laminar flow element (LFE). Because the flow element makes the flow stream laminar, placement in the process does not require straight pipe runs upstream or downstream of the meter, greatly simplifying installation. As compared to thermal mass technologies, the LFE design provides an ultrafast response within 10 milliseconds and offers “instant on” with no warm-up time. Accuracy of ±0.8% of reading ±0.2% full-scale, repeatability of ±0.2% Measure 30 standard gases—user selectable from display 100 to 1 turndown with ranges of 1 SCCM full-scale up to 1000 SLPM Length () 4 Accuracy±(0.8R 0.2FS) Repeatability±0.2% Width ()1.625 Max Pressure (PSI)145 Height ()5.5 Min Flow Rate (LPM)5 Max Flow Rate (LPM)500 Min Flow Rate (mL/min)5000 Max Flow Rate (mL/min)500000 Wetted Materials302 and 303 SS, Viton®, silicone RTV, glass-reinforced nylon, aluminum Min Operating Temperature (° F)14 Min Operating Temperature (° C)-10 Max Operating Temperature (° F)122 Max Operating Temperature (° C)50 Process Connection 3/4 NPT(F) Turn-Down Ratio 100:1 Fluid Type GAS Gas Type Acetylene (C2H2), Air, Argon (Ar), i-Butane (i-C4H10), n-Butane (n-C4H10), Carbon Dioxide (CO2), Carbon Monoxide (CO), Deuterium (D2), Ethane (C2H6), Ethylene/Ethene (C2H4), Helium (He), Hydrogen (H2), Krypton (Kr), Methane (CH4), Neon (Ne), Nitrogen (N2), Nitrous Oxide (N2O), Oxygen (O2), Propane (C3H8), Sulfur Hexaflouride (SF6), Xenon (Xe) Max Particulate Size (microns) 50 Response Time (msec) 10 Power115/230 Electrical Connections 8-pin circular mini-DIN Output (Voltage) Yes Output 0 to 5 VDC Input Signal 0 to 5 VDC and RS-232 Display Type 7-line x 4-digit LCD, 0.25H flow display Communications RS-232 Certified Yes > Each Unit Includes 120/230 VAC power adapter with communications cable 32929-89 NIST-traceable calibration report supplied by the manufacturer

  • Dwyer Instruments 201-WT-7810-C1-60

    $3.181

    Long life and reliable operation is inherent in the design of the 201 series. The use of an external magnet reduces the possibility of magnetic particle build up inside the armature tube and subsequent loss of operation as may occur with the internal magnet repulsion design. Electrical requirements are met by use of hermetically sealed snap action or mercury switches in a variety of actions including SPST, SPDT, DPDT and DPST arrangements. Optional circuits are available for low current/voltage DC, high current DC, or high temperature applications.

  • Dwyer Instruments DA-7035-153-10N

    $1.796

    Series DA-7035N Temperature Switches include the same time-proven switching mechanism used in our Series DA Pressure Switches. Bourdon tube assures high sensitivity and long life. Fully adjustable deadband makes units suitable for a wide range of control applications. Visible, calibrated dial and external adjustments make changing set points simple and fast.

  • Dwyer Instruments DA-7035-153-11N

    $2.103

    Series DA-7035N Temperature Switches include the same time-proven switching mechanism used in our Series DA Pressure Switches. Bourdon tube assures high sensitivity and long life. Fully adjustable deadband makes units suitable for a wide range of control applications. Visible, calibrated dial and external adjustments make changing set points simple and fast.

  • Dwyer Instruments DA-7035-153-1N

    $1.231

    Series DA-7035N Temperature Switches include the same time-proven switching mechanism used in our Series DA Pressure Switches. Bourdon tube assures high sensitivity and long life. Fully adjustable deadband makes units suitable for a wide range of control applications. Visible, calibrated dial and external adjustments make changing set points simple and fast.