Showing 46–54 of 64 results

  • Fluke Calibration 5626-20-P

    $2.043

    Range to 661°C Meets all ITS-90 requirements for resistance ratios Rtp drift &lt, 20mK after 500 hours at 661°C Clibrated accuracy of ± 0.006 °C at 0 °C Banana plugs

  • Fluke Calibration 5628-15-B

    $1.414

    Secondary Standard PRT Temperature Sensors High-temp PRT, 25.5Ω Temperature Range: –200 °C to 661 °C Handle Temp: 0 °C to 80 °C RTPW: 25.5Ω (±0.5Ω) W(Ga): ³ 1.11807 Calibration Uncertainty (k=2): ±0.006 °C at –200 °C ±0.004 °C at 0 °C ±0.009 °C at 420 °C ±0.014 °C at 661 °C Stability: ±0.003 °C Long-Term Drift: &lt, 0.03 °C/500 hours at 661 °C Immersion: At least 12.7 cm (5 in) recommended Sheath: Inconel™ 600 Lead Wires: 4-wire Super-Flex PVC, 22 AGW Termination: 5 Pin DIN for 1502A Size: 0.25 dia. x 15

  • Fluke I40S-EL3X/3PK

    $374

    The Fluke I40S-EL3X/3PK Current Clamp-on Transformer is used for low current measurement, suitable for making measurements up to 40 A, and also measures accurately on 1 A and 5 A secondary current transformers. The I40SEL3X/3PK jaw is capable of being clamped on current conductors up to 15 mm in diameter. Used for Low Current measurement Measurement range: 0 40 A Measures accurately on 1 A and 5 A secondary current transformers Can be clamped on to current conductors up to 15mm in diameter Comes in a pack of 3 Current Transformers

  • Fluke TLK1550-RTLC

    $169

    3 test leads (red, black, green) connected to low-leakage probes 3 alligator clips (red, black, green) Test Leads extend to 25 26mm maximum jaw opening Integral test lead set for the fluke 1550B/1550C/1555 MegaohmMeter

  • Hioki 9010

    $133

    Easy-to-use, current to voltage transformer Intended primarily for application as an input sensor for a recorder A secondary output provides an AC voltage waveform, and can be connected to an input impedance over 1M-ohm BNC terminal Insulated BNC terminal Rated current 500 A AC (10 A to 500 A full scale, 6 ranges selectable) Frequency band width 40 to 1 kHz (±6 % max.) Accuracy (at 50 or 60 Hz) ±3 % f.s. Output rate 0.2 V AC at full scale range (waveform output), Output terminal: Insulated BNC Max. circuit voltage 600 V AC rms (insulated wire) Core jaw dia. Ø46 mm(1.81 in), or 50 mm(1.97 in) × 20 mm(0.79 in) busbar Dimensions, mass 74 mm(2.91 in)W × 184 mm(7.24 in)H × 37 mm(1.46 in)D, 420 g (14.8 oz), cord length: 3 m(9.84 ft)

  • Hioki 9018-50

    $204

    10 Amp to 50 Amp Rated current 500 A AC (10 A to 500 A full scale, 6 ranges selectable) Frequency band width 40 to 3 kHz (±1 % max.), phase ±2.5 ° max. Accuracy (at 50 or 60 Hz) ±1.5 % rdg. ±0.1 % f.s. Output rate 0.2 V AC at full scale range (waveform output), Output terminal: Insulated BNC Max. circuit voltage 600 V AC rms (insulated wire) Core jaw dia. Ø46 mm(1.81 in), or 50 mm(1.97 in) × 20 mm(0.79 in) busbar Power supply None Dimensions, mass 74 mm(2.91 in)W × 184 mm(7.24 in)H × 37 mm(1.46 in)D, 410 g (14.5 oz), cord length: 3 m(9.84 ft)

  • Hioki 9660

    $166

    Hioki Model# 9660 Rated input current 100 A AC Rated output voltage 0.1 V AC Accuracy (at 45 to 66 Hz) Amplitude: ±0.5 % rdg. ±0.2 % f.s. , Full scale (f.s.) is the 3196 range value, Phase: ±1 ° or less (at 90 A or less), ±1.3 ° or less (at 90 A to 100 A) Frequency characteristics 66 Hz to 5 kHz (±1 % or less from accuracy) Max. allowable input continuous 130 A rms (45 to 66 Hz) Max. circuit voltage 300 V AC rms (insulated wire) Core jaw dia. Ø15 mm(0.59 in) Dimensions, mass 46 mm(1.81 in)W × 135 mm(5.31 in)H × 21 mm(0.83 in)D, 230 g (8.1 oz), cord length: 3 m(9.84 ft)

  • Hioki 9661

    $180

    For inverter devices or commercial power lines Up to 500 A, or 1000 A measure Rated primary current AC 500 A Output voltage AC 500 mV f.s. (AC 1 mV/A) Amplitude accuracy ±0.3 % rdg. ±0.01 % f.s. (45 to 66 Hz, f.s.= rated primary current) Phase accuracy ±0.5° (at 45 Hz 5 kHz) Max. allowable input Continuous 550 A rms (at 45 66 Hz) Frequency characteristics 40 Hz to 5 kHz: ± 1.0% (deviation from accuracy) Max. rated voltage to earth AC 600 V rms (insulated wire) Core jaw dia. 46 mm (1.81 in) Dimensions, mass 77 mm (3.03 in) W × 151 mm (5.94 in) H × 42 mm (1.65 in) D, 380 g (13.4 oz), cord length 3 m (9.84 ft)

  • Hioki CT6841

    $936

    Hioki AC/DC clamp sensors are best-in-class current sensors for use with power meters, Memory HiCorders and high performance oscilloscopes. Ideal for use in environmental testing with broad -40˚C to 85˚C temperature range High precision with a clamp-type design, ±0.3% amplitude accuracy, ±0.1° phase accuracy Wide-bandwidth DC to 1 MHz (CT6841), DC to 500 kHz (CT6843) Single-handed operation and robust locking mechanism Reduced effects from magnetic fields, conductor position, and noise from nearby wires For EV/HEV battery charge and discharge efficiency measurement and inverter and power conditioner conversion efficiency evaluation