Showing 1–9 of 578 results
-
$632
Measures up to 66Vrms or VDC Measures up to 65AAC or 14ADC (probe dependent) Displays Min, Max and Avg Volts and Amps, Crest Factor, Peak and K-Factor Calculates and displays Watts, VARs and VA, Power Factor and Displacement Power Factor for single-phase and balanced three-phase Displays THD for voltage and current Displays individual harmonic values for Volts and Amps through the 5th harmonic Captures and displays inrush current phase rotation and RPM Displays temperature in °F or °C Displays resistance up to 2O and conducts continuity and diode tests Stores up to nine complete sets of readings for all volt, amp, power, harmonics and other measurements Configurable from DataView® software or front panel > Each Unit Includes DataView® Software Free for Data Download and Storage Real-time Waveform Display, Analysis and Report Generation
-
$1.034
Measures up to 66Vrms or Vdc Measures up to 65Aac or 14Adc (Probe dependent) Displays Min, Max, and Average Volts and Amps, Crest Factor, Peak value and K-Factor Calculates and displays Watts, VARs and VA, Power Factor and Displacement Power Factor for single-phase and balanced three-phase Displays total harmonic distortion (THD-F and THD-R) for voltage and current Displays individual harmonic values and % for Volts and Amps through the 5th harmonic Captures and displays inrush current waveforms and statistics Stores up to eight screen captures Stores up to 1MB of trend recorded data Configurable from DataView software or front panel Download stored data to DataView software via optical USB port Captures up to 496 alarm events from up to 1 different thresholds Displays and records up to 17 different power quality parameters > Each Unit Includes (3) Color-coded Current Probes (4) Color-coded 1 ft Voltage Leads (4) Color-coded Alligator Clips RS-232 DB9F Optically Coupled Serial Cable NiMH Battery US 12V Power Cord DataView Professional software Carrying Bag Soft Carrying Pouch User Manual
-
$1.035
Measures up to 660Vrms or VDC Measures up to 6500AAC or 1400ADC (probe dependent) Displays Min, Max and Average Volts and Amps, Crest Factor, Peak value and K-Factor Calculates and displays Watts, VARs and VA, Power Factor and Displacement Power Factor for single-phase and balanced three-phase Displays total harmonic distortion (THD-F and THD-R) for voltage and current Displays individual harmonic values and % for Volts and Amps through the 50th harmonic Captures, displays and stores inrush current waveforms and statistics Stores up to eight screen captures Stores up to 1MB of trend recorded data Configurable from DataView® software or front panel Download stored data to DataView® software via optical with isolated USB port Captures up to 4096 alarm events using up to 10 different thresholds Displays and records up to 17 different power quality parameters Includes DataView® software FREE > Each Unit Includes Set of two 10 ft. color-coded leads (red/black) with alligator clips Optically isolated USB cable US 110v power adapter 1.2V NiMH rechargeable batteries Dataview® software Carrying bag Soft carrying pouch Product warranty card User Manual
-
$2.223
True RMS Single-, Two- and Three-PhaseMeasurements at 256 Samples/Cycle, Plus DC Real-Time Color Waveforms Easy-to-Use On-Screen Setup Automatic Current Probe Recognition and Scaling True RMS Voltage and Current Measurement Measures DC Volts, Amps and Power Displays and Captures Voltage, Current and Power Harmonics to 50th Order, Including Direction, in Real-Time Captures Transients Down to 1/256th of a Cycle Stores Comprehensive Data Base of Logged Data Phasor Diagram Display VA, Var And W Per Phase and Total kVAh, VARh and kWh Per Phase and Total Neutral Current Calculated and Displayed for Three-Phase Transformer K-Factor Display Power Factor, Displacement PF Display Captures Up to 51 Transients Short and Long Term Flicker Display Phase Unbalance (Current and Voltage) Harmonic Distortion (Total and Individual) from 1st to 50th Alarms, Surges and Sags Screen Snapshot Function Captures Waveforms or Other Information on the Display > Each Unit Includes Three 193-24-BK AmpFlex® Sensors Dataview® Software for Configuring Data Storage Real-Time Display Analysis and Report Generation
-
$2.223
True RMS Single-, Two- and Three-PhaseMeasurements at 256 Samples/Cycle, Plus DC Real-Time Color Waveforms Easy-to-Use On-Screen Setup Automatic Current Probe Recognition and Scaling True RMS Voltage and Current Measurement Measures DC Volts, Amps and Power Displays and Captures Voltage, Current and Power Harmonics to 50th Order, Including Direction, in Real-Time Captures Transients Down to 1/256th of a Cycle Stores Comprehensive Data Base of Logged Data Phasor Diagram Display VA, Var And W Per Phase and Total kVAh, VARh and kWh Per Phase and Total Neutral Current Calculated and Displayed for Three-Phase Transformer K-Factor Display Power Factor, Displacement PF Display Captures Up to 51 Transients Short and Long Term Flicker Display Phase Unbalance (Current and Voltage) Harmonic Distortion (Total and Individual) from 1st to 50th Alarms, Surges and Sags Screen Snapshot Function Captures Waveforms or Other Information on the Display > Each Unit Includes Three 193-24-BK AmpFlex® Sensors Dataview® Software for Configuring Data Storage Real-Time Display Analysis and Report Generation
-
$3.035
Measurement of TRMS Voltages Up to 1000Vrms AC/DC for Two-, Three-, Four- or Five-Wire Systems Measurement of TRMS Currents Up to 10,000Arms (Sensor Dependent) Direct Measurement of Neutral Current and Voltage Frequency Measurement (40 to 69Hz Systems) Record and Display Trend Data as Fast as Once Per Second for One Month for Up to 25 Variables Transient Detection on all V and I Inputs (Up to 210) Selectable PT and CT Ratios Inrush Current Measurement Calculation of Crest Factors for V and A Calculation of The K-Factor for Transformers Calculation of Short-Term and Long-Term Flicker Calculation of the Three-Phase Voltage Unbalance Harmonic Measurements (Referenced to the Fundamental or RMS Value) for Voltage, Current or Power, Up to 50th Harmonic Stores Up to 10,000 Alarm Events Displays of Harmonic Sequencing and Direction and Calculation of Overall Harmonics Real-Time Display of Phasor Diagrams Including Values and Phase Angles Monitors the Average Value of any Parameter, Calculated for a Period from 1 Sec to 2 Hrs Measurement of Active, Reactive and Apparent Power Per Phase and Their Respective Sum Total Calculation of Power Factor, Displacement Power Factor and Tangent Factor Recording, Time Stamping and Characterization of Disturbance (Swells, Sags and Interruptions, Exceedence of Power and Harmonic Thresholds) 2GB Internal Trend Recording Memory Additional Memory for Alarm, Transient, Inrush and Snapshot Storage Measurement of Energy VAh, VARh, Wh and VADh 65μs/Sample Trend Recording The Max and Min RMS Measurements are Calculated Every Half-Period > Each Unit Includes Dataview® Software for Configuring Data Storage Real-Time Display Analysis and Report Generation
-
$3.035
Measurement of TRMS Voltages Up to 1000Vrms AC/DC for Two-, Three-, Four- or Five-Wire Systems Measurement of TRMS Currents Up to 10,000Arms (Sensor Dependent) Direct Measurement of Neutral Current and Voltage Frequency Measurement (40 to 69Hz Systems) Record and Display Trend Data as Fast as Once Per Second for One Month for Up to 25 Variables Transient Detection on all V and I Inputs (Up to 210) Selectable PT and CT Ratios Inrush Current Measurement Calculation of Crest Factors for V and A Calculation of The K-Factor for Transformers Calculation of Short-Term and Long-Term Flicker Calculation of the Three-Phase Voltage Unbalance Harmonic Measurements (Referenced to the Fundamental or RMS Value) for Voltage, Current or Power, Up to 50th Harmonic Stores Up to 10,000 Alarm Events Displays of Harmonic Sequencing and Direction and Calculation of Overall Harmonics Real-Time Display of Phasor Diagrams Including Values and Phase Angles Monitors the Average Value of any Parameter, Calculated for a Period from 1 Sec to 2 Hrs Measurement of Active, Reactive and Apparent Power Per Phase and Their Respective Sum Total Calculation of Power Factor, Displacement Power Factor and Tangent Factor Recording, Time Stamping and Characterization of Disturbance (Swells, Sags and Interruptions, Exceedence of Power and Harmonic Thresholds) 2GB Internal Trend Recording Memory Additional Memory for Alarm, Transient, Inrush and Snapshot Storage Measurement of Energy VAh, VARh, Wh and VADh 65μs/Sample Trend Recording The Max and Min RMS Measurements are Calculated Every Half-Period > Each Unit Includes Dataview® Software for Configuring Data Storage Real-Time Display Analysis and Report Generation >
-
$2.821
Measurement of TRMS voltages up to 1000Vrms AD/DC for two-, three-, four- or five-wire systems Measurement of TRMS currents up to 6500Arms (sensor dependent) Direct measurement of neutral current and voltage Frequency measurement (40 to 70Hz systems) Records and displays trend data as fast as once per second for one month up to 25 variables Captures up to 210 transient occurrences on all V and A inputs Measures harmonics (referenced to the fundamental or RMS value) for voltage, current or power up to the 50th harmonic Recording, time stamping and characterization of disturbance (swells, sages and interruptions, exceedence of power and harmonic thresholds) 2GB SD Card for Trend Recording memory, Alarm, Snapshot, Transient and Inrush stored in internal flash memory Measures energy VAh, VARh & Wh 65µs/sample transient recording > Each Unit Includes FREE DataView® Software is included for Configuring Real-time Display and Report Generation
-
$2.949
Measurement of TRMS voltages up to 1000Vrms AD/DC for two-, three-, four- or five-wire systems Measurement of TRMS currents up to 6500Arms (sensor dependent) Direct measurement of neutral current and voltage Frequency measurement (40 to 70Hz systems) Records and displays trend data as fast as once per second for one month up to 25 variables Captures up to 210 transient occurrences on all V and A inputs Measures harmonics (referenced to the fundamental or RMS value) for voltage, current or power up to the 50th harmonic Recording, time stamping and characterization of disturbance (swells, sages and interruptions, exceedence of power and harmonic thresholds) 2GB SD Card for Trend Recording memory, Alarm, Snapshot, Transient and Inrush stored in internal flash memory Measures energy VAh, VARh & Wh 65µs/sample transient recording > Each Unit Includes FREE DataView® Software is included for Configuring Real-Time Display and Report Generation