Showing 163–171 of 201 results
-
$3.462
The Keysight 478A provides high efficiency and good radio frequency (RF) match. Used in conjunction with the N432A or 432A power meters, they provide high accuracy even in routine power measurements. These thermistor mounts are temperature compensated for low drift, even in the presence of thermal shocks, permitting measurement of microwave power as low as one microwatt. Each mount contains data showing calibration factor and effective efficiency at six frequencies, directly traceable to the U.S. National Institute Standards and Technology (NIST) at those frequencies where NIST provides calibration service. High accuracy even in routine power measurements Temperature compensated for low drift Measures microwave power as low as one microwatt Shows calibration factor and effective efficiency at 12 frequencies Frequency Range: 10 MHz to 10 GHz Maximum SWR: 10 MHz to 25 MHz 1.75, 25 MHz to 7GHz 1.30, 7 GHz to 10 GHz 1.50 Available options: 478A-H75 and 478A-H76 for frequency range 1 MHz to 1 GHz (Max. SWR 1.3, 1.05 at 50 MHz). 478A-H76 provides standard lab calibration at 50 MHz 1 year standard warranty
-
$4.232
Maximize your investment with five instruments in one device Increase your productivity with extensive built-in power measurement capabilities Flexible IO: LAN/LXI Core, USB and GPIB Lower your cost of ownership with global support & the longest standard warranty in the industry > Each Unit Includes Power Cord
-
$5.301
Maximize your investment with five instruments in one device Increase your productivity with extensive built-in power measurement capabilities Flexible IO: LAN/LXI Core, USB and GPIB Lower your cost of ownership with global support & the longest standard warranty in the industry > Each Unit Includes Power Cord
-
$1.060
Excellent SWR for reducing mismatch uncertainty Accurate calibration and traceability to US National Institute of Standards and Technology (NIST) Compatible with EPM (new N1913A/ 14A, E4418B/ 19B), EPM-P (E4416A/ 17A) and P-series (N1911A/ 12A) power meters, plus the E1416A VXI and discontinued 70100A and 43X power meter Accurate average power measurements over -70 to -20 dBm Frequency range 10 MHz to 18 GHz Diode power sensing element > The 8481D diode power sensor measures average power over the frequency range 10 MHz to 18 GHz and power range -70 to -20 dBm (50 dB dynamic range). The Keysight 11708A 30 dB attenuator is supplied with 8480 series power sensors with the D suffix, for calibration with the power meter 0 dBm, 50 MHz reference.
-
$1.064
Fast measurement speed, up to 400 readings per second with the E4416A Wide dynamic range (-70 dBm to 20 dBm) Calibration factors, linearity ana temperature compensations data stored in EEPROM Excellent SWR for reducing mismatch uncertainty Accurate calibration and traceability to NIST Compatible with EPM (new N1913A/ 14A, E4418B/ 19B), EPM-P (E4416A/ 17A) and P-series (N1911A/ 12A) power meters > The E4412A CW diode power sensor measures average power over the frequency range 10 MHz to 18 GHz and power range -70 to 20 dBm (90 dB dynamic range).
-
$1.410
Fast measurement speed, up to 400 readings per second with the E4416A Wide dynamic range (-70 dBm to 20 dBm) Frequency range from 50 MHz to 26.5 GHz and special options to 33 GHz Calibration factors, linearity and temperature compensation data stored in EEPROM Excellent SWR for reducing mismatch uncertainty Accurate calibration and traceability to NIST Compatible with EPM (new N1913A/ 14A, E4418B/ 19B), EPM-P (E4416A/ 17A) and P-series (N1911A/ 12A) power meters
-
$1.239
Keysight waveguide power sensors are fully compatible with Keysight EPM (E4418B/19B, N1913A/14A), EPM-P (E4416A/17A) and P-Series (N1911A/12A) power meters. The V8486A and W8486A are also compatible with the discontinued or obsolete power meters such as 435B, 436A, 437B, 438A, 70100A, E1416A, E4418A, and E4419A power meters. Frequency: 60 to 90 GHz Compatible with Your Current Keysight Power Meter Best SWR Available 50 MHz Calibration High Reliability
-
$1.453
Measure the average power of all modulation formats Wide dynamic range (-60 dBm to 20 dBm) and frequency range 10 MHz to 18 GHz High maximum power specification Low SWR for reducing mismatch uncertainty Calibration factors, linearity, and temperature compensation data stored in EEPROM Fast measurement speeds (up to 400 readings per second with the E4416A) Compatible with EPM (new N1913A/ 14A, E4418B/ 19B), EPM-P (E4416A/ 17A) and P-series (N1911A/ 12A) power meters > The E9300A diode power sensor measures average power over the frequency range 10 MHz to 18 GHz and power range -60 to 20 dBm (80 dB dynamic range).
-
$2.308
Measure the average power of all modulation formats Wide dynamic range power measurements from -30 dBm to 44 dBm Frequency range 10 MHz to 18 GHz Low SWR for reducing mismatch uncertainty Calibration factors, linearity and temperature compensation data stored in EEPROM Compatible with EPM (new N1913A/ 14A, E4418B/ 19B), EPM-P (E4416A/ 17A) and P-series (N1911A/ 12A) power meters