Showing 127–135 of 201 results

  • Fluke 438-II/BASIC

    $5.121

    The ideal portable motor analysis test tool, the 438-II can help locate, predict, prevent, and troubleshoot power quality problems in three-phase and single-phase power distribution systems, while giving technicians the mechanical and electrical information they need to effectively evaluate motor performance. Measure key parameters on direct-on-line motors including torque, RPM, mechanical power and motor efficiency. Perform dynamic motor analysis by plotting of motor de-rating factor against load according to NEMA guidelines. Calculate mechanical power and efficiency without the need of mechanical sensors, just connect to the input conductors and youre ready to go. Measure electrical power parameters such as voltage, current, power, apparent power, power factor, harmonic distortion and unbalance to identify characteristics that impact motor efficiency Identify power quality issues such as dips, swells, transients, harmonics and unbalance. PowerWave data technology captures fast RMS data, and shows half-cycle averages and waveforms to characterize electrical system dynamics (generator start-ups, UPS switching etc.). Waveform capture function captures 100/120 cycles (50/60 Hz) of each event detected event, in all modes, without set-up. Automatic transient mode captures waveform data at 200 kS/s on all phases simultaneously up to 6 kV. > Each Unit Includes voltage lead set FC WiFi SD card carrying case > Fluke 438-II mechanical metering functions Motor torque Calculates the amount of rotational force (displayed in lb.ft or Nm) developed by a motor and transmitted to a driven mechanical load. The motor torque is the single most critical variable that characterizes the instantaneous mechanical performance of rotating equipment driven by electric motors. Motor speed Provides the instantaneous motor shaft rotational speed. Combined with the motor torque, motor speed provides a snapshot of the mechanical performance of rotating equipment driven by electric motors. Motor mechanical load Measures the actual mechanical power (displayed in hp or kW) produced by motors and provides a direct link to overloading conditions without simply basing it on the motor current. Motor efficiency Shows the effectiveness of each motor within a machine, assembly line, plant, and/or facility in converting electric power to useful mechanical work. By properly aggregating the efficiencies of a population of motors the total (aggregate) efficiency can be estimated. Comparisons to expected motor efficiencies at observed operating conditions can help quantify the cost associated with motor energy inefficiency. How it works Using proprietary algorithms, the Fluke 438-II Power Quality and Motor Analyzer uses threephase current and voltage waveforms to calculate motor torque, speed, load and efficiency at a 1 second update rate. The motor air gap field, as observed via the voltage/current waveforms, provides the basis for the measurements. Mechanical sensors and intrusive no-load motor testing is not required, making it faster than ever to analyze overall electric motor performance. Electrical motor analysis The Fluke 438-II provides a complete breakdown of electrical parameters. Prior to beginning motor analysis, its recommended to make base line power quality measurements to assess the state of harmonics and unbalance on the electrical service output as these two properties can have a serious negative impact, on motor performance. When in Motor Analysis mode, results are summarized for electrical performance, mechanical performance and derating (according to NEMA recommendations). The easy to understand four-level color severity scale indicates motor performance in relation to the recommended electrical parameter levels including rated power, power factor, unbalance and harmonics. For mechanical power you can instantly view the mechanical output power along with motor torque and speed. The mechanical output power is instantly compared with electrical power to provide you with live efficiency measurements. With this feature you can easily measure machine performance during each operation cycle. The NEMA derating screen is updated as the load and the electrical conditions change, and each new measurement is plotted on the tolerance graph as a . In this example we can see that motor is within tolerance but is close to the service factor. This indicates that there may be a need for power quality mitigation, motor maintenance or some other performance improving adjustment. By frequently performing these tests over time, known benchmarks and performance trends can be created, enabling informed maintenance investment decisions.

  • Fluke N4K 3PP54I

    $11.200

    42 BP Binding Posts 1FC1 (GPIB & LAN) PI1 analog/digital input/output Compact, high precision power analyzers – easy to carry and save working space Simple user interface ensures easy, intuitive operation Standard configurations allow users to specify the exact functionality required for their own unique application Accurately display dynamic events on all phases at exactly the same point in time with simultaneous parallel acquisition of all phases All inputs are galvanically isolated to avoid short circuits in all applications Voltage, current and power harmonics up to the 40th FFT analysis, vector diagram display, recorder function and Digital Oscilloscope (DSO) mode included User-selectable average time – from 15 ms up to 3600 s – for dynamic measurements 4 MB on-board memory for storage of measured values RS232 and USB available as standard, optional IEEE 488/Ethernet available Optional process interface available to measure torque and speed with external sensors, includes four analog outputs for easy use on motor and drive applications 341 kHz or 1 MHz sample rates for detailed signal analysis Bandwidth from dc to 3 MHz / 10 MHz for reliable measurement precision Includes Fluke NormaView PC software for setup, data download, analysis & report writing > Each Unit Includes Power supply cable 5.7“ / 144 mm color display Fluke NormaView PC software User’s manual Test certificate Calibration values

  • Fluke NORMA 6003

    $4.403

    The Fluke 6000 Series Portable Wideband Precision Power Analyzers give you more freedom than ever before to make high accuracy power measurements wherever you need to whether in the lab, or in the field. Designed for portability the lightweight, battery powered Fluke 6000 Series eliminates the need to carry large, fragile, expensive analyzers in to environments not suited to them, allowing you to go directly to the load and make measurements in nearly any environment. The Fluke Norma 6000 Series Portable Wideband Precision Power Analyzers give you more freedom than ever before to make high accuracy power measurements wherever you need to-whether in the lab, or in the field. Designed for portability the lightweight, battery powered Fluke 6000 Series eliminates the need to carry large, fragile, expensive analyzers into the field, allowing you to make measurements directly at the load in nearly any environment. By measuring directly at the load, you can discover how the equipment operates under real-world conditions, with real-world variables, not just at a test bench or in the lab. The Fluke 6003 includes three measurement channels which each consist of a voltage and current input making it ideal for three-phase power measurements. The Fluke 6004 includes four measurement channels giving it the capability to measure three-phase power and DC power simultaneously to enable real-time inverter efficiency measurements under real-world conditions. The Fluke 6003 and 6004 models both add the capability to measure mechanical parameters such as speed and torque (from separate transducers) to discover the electrical to mechanical efficiency of the load under a variety of typical operating modes. With the addition of optional measurement accessories, you can even make measurements up to 1,500V DC and 2,000A AC DC on conductors with a diameter of up to 52mm. The instruments compact, battery-powered design combined with a wideband frequency response makes it easier than ever to make measurements on hard to access systems such as inverter drive systems, DC-AC and AC-DC power conversion systems and electric motors without removing them from service. Making these measurements in the field simplifies the troubleshooting and per-formance measurement processes without sacrificing uptime, giving you more accurate test results that will enable you to discover whether your loads are operating as effectively and efficiently as they should be. Continuously operate for up to 6 hours without an external power supply using the 5000mAh Li-ion Internal Battery. Measure safely-safety rated for CAT III 1000V, CAT IV 600V environments Measure three phase AC and DC power Measure three phase power and DC output power at the same time with 3 or 4 channel models, with voltage and current inputs on each channel.

  • Fluke NORMA 6003+

    $6.369

    The Fluke 6000 Series Portable Wideband Precision Power Analyzers give you more freedom than ever before to make high accuracy power measurements wherever you need to whether in the lab, or in the field. Designed for portability the lightweight, battery powered Fluke 6000 Series eliminates the need to carry large, fragile, expensive analyzers in to environments not suited to them, allowing you to go directly to the load and make measurements in nearly any environment. The Fluke Norma 6000 Series Portable Wideband Precision Power Analyzers give you more freedom than ever before to make high accuracy power measurements wherever you need to-whether in the lab, or in the field. Designed for portability the lightweight, battery powered Fluke 6000 Series eliminates the need to carry large, fragile, expensive analyzers into the field, allowing you to make measurements directly at the load in nearly any environment. By measuring directly at the load, you can discover how the equipment operates under real-world conditions, with real-world variables, not just at a test bench or in the lab. The Fluke 6003 includes three measurement channels which each consist of a voltage and current input making it ideal for three-phase power measurements. The Fluke 6004 includes four measurement channels giving it the capability to measure three-phase power and DC power simultaneously to enable real-time inverter efficiency measurements under real-world conditions. The Fluke 6003 and 6004 models both add the capability to measure mechanical parameters such as speed and torque (from separate transducers) to discover the electrical to mechanical efficiency of the load under a variety of typical operating modes. With the addition of optional measurement accessories, you can even make measurements up to 1,500V DC and 2,000A AC DC on conductors with a diameter of up to 52mm. The instruments compact, battery-powered design combined with a wideband frequency response makes it easier than ever to make measurements on hard to access systems such as inverter drive systems, DC-AC and AC-DC power conversion systems and electric motors without removing them from service. Making these measurements in the field simplifies the troubleshooting and per-formance measurement processes without sacrificing uptime, giving you more accurate test results that will enable you to discover whether your loads are operating as effectively and efficiently as they should be. Continuously operate for up to 6 hours without an external power supply using the 5000mAh Li-ion Internal Battery. Measure safely-safety rated for CAT III 1000V, CAT IV 600V environments Measure three phase AC and DC power Measure three phase power and DC output power at the same time with 3 or 4 channel models, with voltage and current inputs on each channel.

  • Fluke NORMA 6004

    $6.369

    The Fluke 6000 Series Portable Wideband Precision Power Analyzers give you more freedom than ever before to make high accuracy power measurements wherever you need to-whether in the lab, or in the field. Designed for portability the lightweight, battery powered Fluke 6000 Series eliminates the need to carry large, fragile, expensive analyzers in to environments not suited to them, allowing you to go directly to the load and make measurements in nearly any environment. The Fluke Norma 6000 Series Portable Wideband Precision Power Analyzers give you more freedom than ever before to make high accuracy power measurements wherever you need to-whether in the lab, or in the field. Designed for portability the lightweight, battery powered Fluke 6000 Series eliminates the need to carry large, fragile, expensive analyzers into the field, allowing you to make measurements directly at the load in nearly any environment. By measuring directly at the load, you can discover how the equipment operates under real-world conditions, with real-world variables, not just at a test bench or in the lab. The Fluke 6003 includes three measurement channels which each consist of a voltage and current input making it ideal for three-phase power measurements. The Fluke 6004 includes four measurement channels giving it the capability to measure three-phase power and DC power simultaneously to enable real-time inverter efficiency measurements under real-world conditions. The Fluke 6003 and 6004 models both add the capability to measure mechanical parameters such as speed and torque (from separate transducers) to discover the electrical to mechanical efficiency of the load under a variety of typical operating modes. With the addition of optional measurement accessories, you can even make measurements up to 1,500V DC and 2,000A AC DC on conductors with a diameter of up to 52mm. The instruments compact, battery-powered design combined with a wideband frequency response makes it easier than ever to make measurements on hard to access systems such as inverter drive systems, DC-AC and AC-DC power conversion systems and electric motors without removing them from service. Making these measurements in the field simplifies the troubleshooting and per-formance measurement processes without sacrificing uptime, giving you more accurate test results that will enable you to discover whether your loads are operating as effectively and efficiently as they should be. Continuously operate for up to 6 hours without an external power supply using the 5000mAh Li-ion Internal Battery. Measure safely-safety rated for CAT III 1000V, CAT IV 600V environments Measure three phase AC and DC power Measure three phase power and DC output power at the same time with 3 or 4 channel models, with voltage and current inputs on each channel.

  • Hioki 3169

    $1.889

    Hioki Model# 3169-20-01/5000 Measure up to two 3-phase, 3-wire systems (displays voltage and current for three lines) Measure up to four single-phase, 2-wire systems 5 A to 5000 A range Compact and light weight PC card data storage Power recording for individual waveforms Simultaneous recording of demand values and harmonics Basic Accuracy: Voltage: ±0.2 % rdg. ±0.1 % f.s., Current:±0.2 % rdg. ±0.1 % f.s. Clamp accuracy (active power, at 45 to 66 Hz) Measurement Ranges: Voltage: 150 V to 600 V, 3 ranges, Current: 5 A to 5 kA, 8 ranges (use clamp sensor), Power: 750 W to 9 MW, 16 combination patterns Data storage Internal memory: 1 MB, Flash Card: Up to 528 MB Power supply 100 to 240 V AC, 50/60 Hz Dimensions: 210 mm(8.27 in)W × 160 mm(6.30 in)H × 60 mm(2.36 in)D, 1.2 kg (42.3 oz) > Each Unit Includes 3169-20 Power quality analyzer 9661 CT 500A clamps 9667 (3) 5000A Clamps 3169 Hard Case Software 32MB Flash Card

  • Hioki 3169-21-01/1000

    $1.923

    Measure up to two 3-phase, 3-wire systems (displays voltage and current for three lines) Measure up to four single-phase, 2-wire systems 5 A to 5000 A range Compact and light weight PC card data storage Power recording for individual waveforms Simultaneous recording of demand values and harmonics Basic Accuracy: Voltage: ±0.2 % rdg. ±0.1 % f.s., Current:±0.2 % rdg. ±0.1 % f.s. Clamp accuracy (active power, at 45 to 66 Hz) Measurement Ranges: Voltage: 150 V to 600 V, 3 ranges, Current: 5 A to 5 kA, 8 ranges (use clamp sensor), Power: 750 W to 9 MW, 16 combination patterns Data storage Internal memory: 1 MB, Flash Card: Up to 528 MB Power supply 100 to 240 V AC, 50/60 Hz Dimensions: 210 mm(8.27 in)W × 160 mm(6.30 in)H × 60 mm(2.36 in)D, 1.2 kg (42.3 oz) > Each Unit Includes 9438-03 voltage cord set (1 cord each of black, red, yellow, and blue) Voltage cord Ground adapter (3P to 2P) Input cord label Operating manuals (Advanced edition and Quick Start Guide) CD-R (Advanced edition and RS-232C interface operating manuals) 9441 connection cable

  • Hioki 3169-21-01/500

    $1.795

    Measure up to two 3-phase, 3-wire systems (displays voltage and current for three lines) Measure up to four single-phase, 2-wire systems 5 A to 5000 A range Compact and light weight PC card data storage Power recording for individual waveforms Simultaneous recording of demand values and harmonics Basic Accuracy: Voltage: ±0.2 % rdg. ±0.1 % f.s., Current:±0.2 % rdg. ±0.1 % f.s. Clamp accuracy (active power, at 45 to 66 Hz) Measurement Ranges: Voltage: 150 V to 600 V, 3 ranges, Current: 5 A to 5 kA, 8 ranges (use clamp sensor), Power: 750 W to 9 MW, 16 combination patterns Data storage Internal memory: 1 MB, Flash Card: Up to 528 MB Power supply 100 to 240 V AC, 50/60 Hz Dimensions: 210 mm(8.27 in)W × 160 mm(6.30 in)H × 60 mm(2.36 in)D, 1.2 kg (42.3 oz) > Each Unit Includes 9438-03 voltage cord set (1 cord each of black, red, yellow, and blue) Voltage cord Ground adapter (3P to 2P) Input cord label Operating manuals (Advanced edition and Quick Start Guide) CD-R (Advanced edition and RS-232C interface operating manuals) 9441 connection cable

  • Hioki 3169-21-01/5000

    $2.094

    Measure up to two 3-phase, 3-wire systems (displays voltage and current for three lines) Measure up to four single-phase, 2-wire systems 5 A to 5000 A range Compact and light weight PC card data storage Power recording for individual waveforms Simultaneous recording of demand values and harmonics Basic Accuracy: Voltage: ±0.2 % rdg. ±0.1 % f.s., Current:±0.2 % rdg. ±0.1 % f.s. Clamp accuracy (active power, at 45 to 66 Hz) Measurement Ranges: Voltage: 150 V to 600 V, 3 ranges, Current: 5 A to 5 kA, 8 ranges (use clamp sensor), Power: 750 W to 9 MW, 16 combination patterns Data storage Internal memory: 1 MB, Flash Card: Up to 528 MB Power supply 100 to 240 V AC, 50/60 Hz Dimensions: 210 mm(8.27 in)W × 160 mm(6.30 in)H × 60 mm(2.36 in)D, 1.2 kg (42.3 oz) > Each Unit Includes 9438-03 voltage cord set (1 cord each of black, red, yellow, and blue) Voltage cord Ground adapter (3P to 2P) Input cord label Operating manuals (Advanced edition and Quick Start Guide) CD-R (Advanced edition and RS-232C interface operating manuals) 9441 connection cable