Fluke 753 VIP1
$3.437Exclusive VIP Kit includes FREE Calibration Labels, FREE FUSE Letherman Tool, FREE Pelican 1500-C Case, FREE T/C Lead, and FREE Li-Ion Battery Pack. Flukes next generation Documenting, Multifunction Calibrator improving upon the popular 74X Series. Overview Youre going to love what weve done with your calibrator. The 753 is everything you needed and wished for in the 743B and more! The 753 does the work of several tools sourcing, simulating and measuring pressure, temperature, and electrical signals in one rugged, hand-held device. Youll fall in love with the new improved graphical screen, Li-Ion battery for longer life, USB port and new accessories to complete the package. For documentation, the 753 automates calibration procedures and captures your data. And, of course, it helps you meet rigorous standards like ISO 9000, FDA, EPA and OSHA regulations. Save over $485 with the Fluke 753 VIP Kit. Limited Time Offer. FREET/C Lead Set (22171T) FREE Leatherman PST Tool (80141TL) FREE Li-ion Battery Pack for Fluke 753 and 754 (BP7240) FREE Pelican Carrying Case (1500-C) FREE 128 Pack of Green Calibration Labels > Measure volts, mA, RTDs, thermocouples, frequency, and ohms to test sensors, transmitters and other instruments Source/simulate volts, mA, thermocouples , RTDs, frequency, ohms, and pressure to calibrate transmitters Power transmitters during test using loop supply with simultaneous mA measurement Measure/source pressure using any of 29 Fluke pressure modules Advanced features like autostep, custom units, user entered values during test, one-point and two-point switch testing, square root DP flow testing, programmable measurement delay and more Includes the new C799 Field soft case Three-year warranty > Each Unit Includes Free Calibration Labels Free FUSE Letherman Tool Free Pelican 1500-C Case Free T/C Lead Free Li-Ion Battery Pack Three sets of stackable test leads Three sets of TP220 test probes with three sets of extended tooth alligator clips Two sets AC280 hook clips BP7240 Li-ion battery pack BC7240 battery charger C799 field soft case USB communication cable Getting started guide Instruction manual on CDROM NIST traceable certificate of calibration > Measurement Accuracy Voltage DC Range /Resolution 1 Year 2 Years 100.000 mV 0.02% 0.005 mV 0.03% 0.005 mV 3.00000 V 0.02% 0.00005 V 0.03% 0.00005 V 30.0000 V 0.02% 0.0005 V 0.03% 0.0005 V 300.00 V 0.05% 0.05 V 0.07% 0.05 V Voltage AC 3.000 V (40 Hz to 500 Hz) / 0.001 V 0.5% 0.002 V 1.0% 0.004 V 30.00 V (40 Hz to 500 Hz) / 0.01 V 0.5% 0.02 V 1.0% 0.04 V 300.0 V (40 Hz to 500 Hz) / 0.1 V 0.5% 0.2 V 1.0% 0.2 V Current DC 30.000 mA 0.01% 5 uA 0.015% 7 uA 110.00 mA 0.01% 20 uA 0.015% 30 uA Resistance 10.000 Ω 0.05% 50 mΩ 0.07% 70 mΩ 100.00 Ω 0.05% 50 mΩ 0.07% 70 mΩ 1.0000 kΩ 0.05% 500 mΩ 0.07% 0.5 Ω 10.000 kΩ 0.1% 10 Ω 0.15% 15 Ω Frequency 1.00 to 110.00 Hz / 0.01 Hz 0.05 Hz 110.1 to 1100.0 Hz / 0.1 Hz 0.5 Hz 1.101 to 11.000 kHz / 0.001 kHz 0.005 kHz 11.01 to 50.00 kHz / 0.01 kHz 0.05 kHz Source Accuracy 1 Year 2 Years Voltage DC 100.000 mV 0.01% 0.005 mV 0.015% 0.005 mV 1.00000 V 0.01% 0.00005 V 0.015% 0.0005 V 15.0000 V 0.01% 0.0005 V 0.015% 0.0005 V Current DC 22.000 mA (source) 0.01% 0.003 mA 0.02% 0.003 mA Current sink (simulate) 0.02% 0.007 mA 0.04% 0.007 mA Resistance 10.000 Ω 0.01% 10 mΩ 0.015% 15 mΩ 100.00 Ω 0.01% 20 mΩ 0.015% 30 mΩ 1.0000 kΩ 0.02% 0.2 Ω 0.03% 0.3 Ω 10.000 kΩ 0.02% 3 Ω 0.03% 5 Ω Frequency 0.1 to 10.99 Hz 0.01 Hz 0.01 to 10.99 Hz 0.01 Hz 11.00 to 109.99 Hz 0.1 Hz 110.0 to 1099.9 Hz 0.1 Hz 1.100 to 21.999 kHz 0.002 kHz 22.000 to 50.000 kHz 0.005 kHz Technical Data Data log functions Measure functions Voltage, current, resistance, frequency, temperature, pressure Reading rate 1, 2, 5, 10, 20, 30, or 60 readings/minute Maximum record length 8000 readings (7980 for 30 or 60 readings/minute) Ramp functions Source functions Voltage, current, resistance, frequency, temperature Rate 4 steps/second Trip detect Continuity or voltage (continuity detection not available when sourcing current) Loop power function Voltage Selectable, 26 V Accuracy 10%, 18 V minimum at 22 mA Maximum current 25 mA, short circuit protected Maximum input voltage 50 V DC Step functions Source functions Voltage, current, resistance, frequency, temperature Manual step Selectable step, change with arrow buttons Autostep Fully programmable for function, start delay, stepvalue, time per step, repeat Environmental Specifications Operating temperature -10°C to 50°C Storage temperature -20°C to 60°C Dust/water resistance Meets IP52, IEC 529 Operating altitude 3000 m above mean sea level (9842 ft) Safety Specifications Agency approvals CAN/CSA C22.2 No 1010.1-92, ASNI/ISA S82.01-1994, UL3111, and EN610-1:1993 Mechanical and General Specifications Size 136 x 245 x 63 mm (5.4 x 9.6 x 2.5 in) Weight 1.2 kg (2.7 lb) Batteries Internal Battery Pack Li-ion: 7.2 V, 4400 mAh, 30 Wh Battery life >, 8 hours typical Battery replacement Via snap-shut door without opening calibrator, no tools required Side port connections Pressure module connector USB Connector to interface to your PC Connection for optional battery charger/eliminator Data storage capacity 1 week of calibration procedures results 90 day specifications The standard specification interval for the 750 Series are 1 and 2 years. Typical 90 day measurement and source accuracy can be estimated by dividing the one year % of reading or % of output specifications by 2. Floor specifications, expressed as % of full scale or counts or ohms remain constant. Temperature, Resistance Temperature Detectors Degrees or % of reading Type (α) Range °C Measure °C1 1 year 2 year 100 Ω Pt (385) -200 to 100 0.07°C 0.14°C 100 to 800 0.02% 0.05°C 0.04% 0.10°C 200 Ω Pt (385) -200 to 100 0.07°C 0.14°C 100 to 630 0.02% 0.05°C 0.04% 0.10°C 500 Ω Pt (385) -200 to 100 0.07°C 0.14°C 100 to 630 0.02% 0.05°C 0.04% 0.10°C 1000 Ω Pt (385) -200 to…