Showing 82–90 of 200 results

  • Fluke 753 VIP1

    $3.437

    Exclusive VIP Kit includes FREE Calibration Labels, FREE FUSE Letherman Tool, FREE Pelican 1500-C Case, FREE T/C Lead, and FREE Li-Ion Battery Pack. Flukes next generation Documenting, Multifunction Calibrator improving upon the popular 74X Series. Overview Youre going to love what weve done with your calibrator. The 753 is everything you needed and wished for in the 743B and more! The 753 does the work of several tools sourcing, simulating and measuring pressure, temperature, and electrical signals in one rugged, hand-held device. Youll fall in love with the new improved graphical screen, Li-Ion battery for longer life, USB port and new accessories to complete the package. For documentation, the 753 automates calibration procedures and captures your data. And, of course, it helps you meet rigorous standards like ISO 9000, FDA, EPA and OSHA regulations. Save over $485 with the Fluke 753 VIP Kit. Limited Time Offer. FREET/C Lead Set (22171T) FREE Leatherman PST Tool (80141TL) FREE Li-ion Battery Pack for Fluke 753 and 754 (BP7240) FREE Pelican Carrying Case (1500-C) FREE 128 Pack of Green Calibration Labels > Measure volts, mA, RTDs, thermocouples, frequency, and ohms to test sensors, transmitters and other instruments Source/simulate volts, mA, thermocouples , RTDs, frequency, ohms, and pressure to calibrate transmitters Power transmitters during test using loop supply with simultaneous mA measurement Measure/source pressure using any of 29 Fluke pressure modules Advanced features like autostep, custom units, user entered values during test, one-point and two-point switch testing, square root DP flow testing, programmable measurement delay and more Includes the new C799 Field soft case Three-year warranty > Each Unit Includes Free Calibration Labels Free FUSE Letherman Tool Free Pelican 1500-C Case Free T/C Lead Free Li-Ion Battery Pack Three sets of stackable test leads Three sets of TP220 test probes with three sets of extended tooth alligator clips Two sets AC280 hook clips BP7240 Li-ion battery pack BC7240 battery charger C799 field soft case USB communication cable Getting started guide Instruction manual on CDROM NIST traceable certificate of calibration > Measurement Accuracy Voltage DC Range /Resolution 1 Year 2 Years 100.000 mV 0.02% 0.005 mV 0.03% 0.005 mV 3.00000 V 0.02% 0.00005 V 0.03% 0.00005 V 30.0000 V 0.02% 0.0005 V 0.03% 0.0005 V 300.00 V 0.05% 0.05 V 0.07% 0.05 V Voltage AC 3.000 V (40 Hz to 500 Hz) / 0.001 V 0.5% 0.002 V 1.0% 0.004 V 30.00 V (40 Hz to 500 Hz) / 0.01 V 0.5% 0.02 V 1.0% 0.04 V 300.0 V (40 Hz to 500 Hz) / 0.1 V 0.5% 0.2 V 1.0% 0.2 V Current DC 30.000 mA 0.01% 5 uA 0.015% 7 uA 110.00 mA 0.01% 20 uA 0.015% 30 uA Resistance 10.000 Ω 0.05% 50 mΩ 0.07% 70 mΩ 100.00 Ω 0.05% 50 mΩ 0.07% 70 mΩ 1.0000 kΩ 0.05% 500 mΩ 0.07% 0.5 Ω 10.000 kΩ 0.1% 10 Ω 0.15% 15 Ω Frequency 1.00 to 110.00 Hz / 0.01 Hz 0.05 Hz 110.1 to 1100.0 Hz / 0.1 Hz 0.5 Hz 1.101 to 11.000 kHz / 0.001 kHz 0.005 kHz 11.01 to 50.00 kHz / 0.01 kHz 0.05 kHz Source Accuracy 1 Year 2 Years Voltage DC 100.000 mV 0.01% 0.005 mV 0.015% 0.005 mV 1.00000 V 0.01% 0.00005 V 0.015% 0.0005 V 15.0000 V 0.01% 0.0005 V 0.015% 0.0005 V Current DC 22.000 mA (source) 0.01% 0.003 mA 0.02% 0.003 mA Current sink (simulate) 0.02% 0.007 mA 0.04% 0.007 mA Resistance 10.000 Ω 0.01% 10 mΩ 0.015% 15 mΩ 100.00 Ω 0.01% 20 mΩ 0.015% 30 mΩ 1.0000 kΩ 0.02% 0.2 Ω 0.03% 0.3 Ω 10.000 kΩ 0.02% 3 Ω 0.03% 5 Ω Frequency 0.1 to 10.99 Hz 0.01 Hz 0.01 to 10.99 Hz 0.01 Hz 11.00 to 109.99 Hz 0.1 Hz 110.0 to 1099.9 Hz 0.1 Hz 1.100 to 21.999 kHz 0.002 kHz 22.000 to 50.000 kHz 0.005 kHz Technical Data Data log functions Measure functions Voltage, current, resistance, frequency, temperature, pressure Reading rate 1, 2, 5, 10, 20, 30, or 60 readings/minute Maximum record length 8000 readings (7980 for 30 or 60 readings/minute) Ramp functions Source functions Voltage, current, resistance, frequency, temperature Rate 4 steps/second Trip detect Continuity or voltage (continuity detection not available when sourcing current) Loop power function Voltage Selectable, 26 V Accuracy 10%, 18 V minimum at 22 mA Maximum current 25 mA, short circuit protected Maximum input voltage 50 V DC Step functions Source functions Voltage, current, resistance, frequency, temperature Manual step Selectable step, change with arrow buttons Autostep Fully programmable for function, start delay, stepvalue, time per step, repeat Environmental Specifications Operating temperature -10°C to 50°C Storage temperature -20°C to 60°C Dust/water resistance Meets IP52, IEC 529 Operating altitude 3000 m above mean sea level (9842 ft) Safety Specifications Agency approvals CAN/CSA C22.2 No 1010.1-92, ASNI/ISA S82.01-1994, UL3111, and EN610-1:1993 Mechanical and General Specifications Size 136 x 245 x 63 mm (5.4 x 9.6 x 2.5 in) Weight 1.2 kg (2.7 lb) Batteries Internal Battery Pack Li-ion: 7.2 V, 4400 mAh, 30 Wh Battery life &gt, 8 hours typical Battery replacement Via snap-shut door without opening calibrator, no tools required Side port connections Pressure module connector USB Connector to interface to your PC Connection for optional battery charger/eliminator Data storage capacity 1 week of calibration procedures results 90 day specifications The standard specification interval for the 750 Series are 1 and 2 years. Typical 90 day measurement and source accuracy can be estimated by dividing the one year % of reading or % of output specifications by 2. Floor specifications, expressed as % of full scale or counts or ohms remain constant. Temperature, Resistance Temperature Detectors Degrees or % of reading Type (α) Range °C Measure °C1 1 year 2 year 100 Ω Pt (385) -200 to 100 0.07°C 0.14°C 100 to 800 0.02% 0.05°C 0.04% 0.10°C 200 Ω Pt (385) -200 to 100 0.07°C 0.14°C 100 to 630 0.02% 0.05°C 0.04% 0.10°C 500 Ω Pt (385) -200 to 100 0.07°C 0.14°C 100 to 630 0.02% 0.05°C 0.04% 0.10°C 1000 Ω Pt (385) -200 to…

  • Fluke 753 VIP2

    $3.437

    Exclusive VIP Kit includes FREE Calibration Labels, FREE Fluke 113 DMM, FREE Pelican 1500-C Case, and FREE FUSE Leatherman Tool. Flukes next generation Documenting, Multifunction Calibrator improving upon the popular 74X Series. Overview Youre going to love what weve done with your calibrator. The 753 is everything you needed and wished for in the 743B and more! The 753 does the work of several tools sourcing, simulating and measuring pressure, temperature, and electrical signals in one rugged, hand-held device. Youll fall in love with the new improved graphical screen, Li-Ion battery for longer life, USB port and new accessories to complete the package. For documentation, the 753 automates calibration procedures and captures your data. And, of course, it helps you meet rigorous standards like ISO 9000, FDA, EPA and OSHA regulations. Want HART communication built into your 753 calibrator? Consider the Fluke 754 Documenting Process Calibrator with HART. Measure volts, mA, RTDs, thermocouples, frequency, and ohms to test sensors, transmitters and other instruments Source/simulate volts, mA, thermocouples , RTDs, frequency, ohms, and pressure to calibrate transmitters Power transmitters during test using loop supply with simultaneous mA measurement Measure/source pressure using any of 29 Fluke pressure modules Advanced features like autostep, custom units, user entered values during test, one-point and two-point switch testing, square root DP flow testing, programmable measurement delay and more Includes the new C799 Field soft case Three-year warranty > Each Unit Includes Free Calibration Labels Free Fluke 113 DMM (must call to add calibration for this item) Free Pelican 1500-C Case Free FUSE Leatherman Tool Three sets of stackable test leads Three sets of TP220 test probes with three sets of extended tooth alligator clips Two sets AC280 hook clips BP7240 Li-ion battery pack BC7240 battery charger C799 field soft case USB communication cable Getting started guide Instruction manual on CDROM NIST traceable certificate of calibration > Measurement Accuracy Voltage DC Range /Resolution 1 Year 2 Years 100.000 mV 0.02% 0.005 mV 0.03% 0.005 mV 3.00000 V 0.02% 0.00005 V 0.03% 0.00005 V 30.0000 V 0.02% 0.0005 V 0.03% 0.0005 V 300.00 V 0.05% 0.05 V 0.07% 0.05 V Voltage AC 3.000 V (40 Hz to 500 Hz) / 0.001 V 0.5% 0.002 V 1.0% 0.004 V 30.00 V (40 Hz to 500 Hz) / 0.01 V 0.5% 0.02 V 1.0% 0.04 V 300.0 V (40 Hz to 500 Hz) / 0.1 V 0.5% 0.2 V 1.0% 0.2 V Current DC 30.000 mA 0.01% 5 uA 0.015% 7 uA 110.00 mA 0.01% 20 uA 0.015% 30 uA Resistance 10.000 Ω 0.05% 50 mΩ 0.07% 70 mΩ 100.00 Ω 0.05% 50 mΩ 0.07% 70 mΩ 1.0000 kΩ 0.05% 500 mΩ 0.07% 0.5 Ω 10.000 kΩ 0.1% 10 Ω 0.15% 15 Ω Frequency 1.00 to 110.00 Hz / 0.01 Hz 0.05 Hz 110.1 to 1100.0 Hz / 0.1 Hz 0.5 Hz 1.101 to 11.000 kHz / 0.001 kHz 0.005 kHz 11.01 to 50.00 kHz / 0.01 kHz 0.05 kHz Source Accuracy 1 Year 2 Years Voltage DC 100.000 mV 0.01% 0.005 mV 0.015% 0.005 mV 1.00000 V 0.01% 0.00005 V 0.015% 0.0005 V 15.0000 V 0.01% 0.0005 V 0.015% 0.0005 V Current DC 22.000 mA (source) 0.01% 0.003 mA 0.02% 0.003 mA Current sink (simulate) 0.02% 0.007 mA 0.04% 0.007 mA Resistance 10.000 Ω 0.01% 10 mΩ 0.015% 15 mΩ 100.00 Ω 0.01% 20 mΩ 0.015% 30 mΩ 1.0000 kΩ 0.02% 0.2 Ω 0.03% 0.3 Ω 10.000 kΩ 0.02% 3 Ω 0.03% 5 Ω Frequency 0.1 to 10.99 Hz 0.01 Hz 0.01 to 10.99 Hz 0.01 Hz 11.00 to 109.99 Hz 0.1 Hz 110.0 to 1099.9 Hz 0.1 Hz 1.100 to 21.999 kHz 0.002 kHz 22.000 to 50.000 kHz 0.005 kHz Technical Data Data log functions Measure functions Voltage, current, resistance, frequency, temperature, pressure Reading rate 1, 2, 5, 10, 20, 30, or 60 readings/minute Maximum record length 8000 readings (7980 for 30 or 60 readings/minute) Ramp functions Source functions Voltage, current, resistance, frequency, temperature Rate 4 steps/second Trip detect Continuity or voltage (continuity detection not available when sourcing current) Loop power function Voltage Selectable, 26 V Accuracy 10%, 18 V minimum at 22 mA Maximum current 25 mA, short circuit protected Maximum input voltage 50 V DC Step functions Source functions Voltage, current, resistance, frequency, temperature Manual step Selectable step, change with arrow buttons Autostep Fully programmable for function, start delay, stepvalue, time per step, repeat Environmental Specifications Operating temperature -10°C to 50°C Storage temperature -20°C to 60°C Dust/water resistance Meets IP52, IEC 529 Operating altitude 3000 m above mean sea level (9842 ft) Safety Specifications Agency approvals CAN/CSA C22.2 No 1010.1-92, ASNI/ISA S82.01-1994, UL3111, and EN610-1:1993 Mechanical and General Specifications Size 136 x 245 x 63 mm (5.4 x 9.6 x 2.5 in) Weight 1.2 kg (2.7 lb) Batteries Internal Battery Pack Li-ion: 7.2 V, 4400 mAh, 30 Wh Battery life &gt, 8 hours typical Battery replacement Via snap-shut door without opening calibrator, no tools required Side port connections Pressure module connector USB Connector to interface to your PC Connection for optional battery charger/eliminator Data storage capacity 1 week of calibration procedures results 90 day specifications The standard specification interval for the 750 Series are 1 and 2 years. Typical 90 day measurement and source accuracy can be estimated by dividing the one year % of reading or % of output specifications by 2. Floor specifications, expressed as % of full scale or counts or ohms remain constant. Temperature, Resistance Temperature Detectors Degrees or % of reading Type (α) Range °C Measure °C1 1 year 2 year 100 Ω Pt (385) -200 to 100 0.07°C 0.14°C 100 to 800 0.02% 0.05°C 0.04% 0.10°C 200 Ω Pt (385) -200 to 100 0.07°C 0.14°C 100 to 630 0.02% 0.05°C 0.04% 0.10°C 500 Ω Pt (385) -200 to 100 0.07°C 0.14°C 100 to 630 0.02% 0.05°C 0.04% 0.10°C 1000 Ω Pt (385) -200 to 100 0.07°C 0.14°C 100 to 630 0.02% 0.05°C 0.04% 0.10°C 100 Ω Pt (3916) -200 to 100 0.07°C 0.14°C 100 to 630 0.02% 0.05°C 0.04%…

  • Fluke 753-154-BU

    $5.104

    Fluke 753 Overview You’re going to love what we’ve done with your calibrator. The 753 is everything you needed and wished for in the 743B and more! The 753 does the work of several tools – sourcing, simulating and measuring pressure, temperature, and electrical signals in one rugged, hand-held device. You’ll fall in love with the new improved graphical screen, Li-Ion battery for longer life, USB port and new accessories to complete the package. For documentation, the 753 automates calibration procedures and captures your data. And, of course, it helps you meet rigorous standards like ISO 9000, FDA, EPA and OSHA regulations. Want HART communication built into your 753 calibrator? Consider the Fluke 754 Documenting Process Calibrator with HART. Fluke 753 Highlights Save over $485 with Fluke 753 VIP Kit. Measure volts, mA, RTDs, thermocouples, frequency, and ohms to test sensors, transmitters and other instruments Source/simulate volts, mA, thermocouples , RTDs, frequency, ohms, and pressure to calibrate transmitters Power transmitters during test using loop supply with simultaneous mA measurement Measure/source pressure using any of 29 Fluke pressure modules Advanced features like autostep, custom units, user entered values during test, one-point and two-point switch testing, square root DP flow testing, programmable measurement delay and more Includes the new C799 Field soft case Three-year warranty > Each Fluke 753 Includes Three sets of stackable test leads Three sets of TP220 test probes with three sets of “extended tooth” alligator clips Two sets AC280 hook clips BP7240 Li-ion battery pack BC7240 battery charger C799 field soft case USB communication cable Getting started guide Instruction manual on CDROM NIST traceable certificate of calibration Rugged Case > Measurement Accuracy Voltage DC Range /Resolution 1 Year 2 Years 100.000 mV 0.02% 0.005 mV 0.03% 0.005 mV 3.00000 V 0.02% 0.00005 V 0.03% 0.00005 V 30.0000 V 0.02% 0.0005 V 0.03% 0.0005 V 300.00 V 0.05% 0.05 V 0.07% 0.05 V Voltage AC 3.000 V (40 Hz to 500 Hz) / 0.001 V 0.5% 0.002 V 1.0% 0.004 V 30.00 V (40 Hz to 500 Hz) / 0.01 V 0.5% 0.02 V 1.0% 0.04 V 300.0 V (40 Hz to 500 Hz) / 0.1 V 0.5% 0.2 V 1.0% 0.2 V Current DC 30.000 mA 0.01% 5 uA 0.015% 7 uA 110.00 mA 0.01% 20 uA 0.015% 30 uA Resistance 10.000 Ω 0.05% 50 mΩ 0.07% 70 mΩ 100.00 Ω 0.05% 50 mΩ 0.07% 70 mΩ 1.0000 kΩ 0.05% 500 mΩ 0.07% 0.5 Ω 10.000 kΩ 0.1% 10 Ω 0.15% 15 Ω Frequency 1.00 to 110.00 Hz / 0.01 Hz 0.05 Hz 110.1 to 1100.0 Hz / 0.1 Hz 0.5 Hz 1.101 to 11.000 kHz / 0.001 kHz 0.005 kHz 11.01 to 50.00 kHz / 0.01 kHz 0.05 kHz Source Accuracy 1 Year 2 Years Voltage DC 100.000 mV 0.01% 0.005 mV 0.015% 0.005 mV 1.00000 V 0.01% 0.00005 V 0.015% 0.0005 V 15.0000 V 0.01% 0.0005 V 0.015% 0.0005 V Current DC 22.000 mA (source) 0.01% 0.003 mA 0.02% 0.003 mA Current sink (simulate) 0.02% 0.007 mA 0.04% 0.007 mA Resistance 10.000 Ω 0.01% 10 mΩ 0.015% 15 mΩ 100.00 Ω 0.01% 20 mΩ 0.015% 30 mΩ 1.0000 kΩ 0.02% 0.2 Ω 0.03% 0.3 Ω 10.000 kΩ 0.02% 3 Ω 0.03% 5 Ω Frequency 0.1 to 10.99 Hz 0.01 Hz 0.01 to 10.99 Hz 0.01 Hz 11.00 to 109.99 Hz 0.1 Hz 110.0 to 1099.9 Hz 0.1 Hz 1.100 to 21.999 kHz 0.002 kHz 22.000 to 50.000 kHz 0.005 kHz Technical Data Data log functions Measure functions Voltage, current, resistance, frequency, temperature, pressure Reading rate 1, 2, 5, 10, 20, 30, or 60 readings/minute Maximum record length 8000 readings (7980 for 30 or 60 readings/minute) Ramp functions Source functions Voltage, current, resistance, frequency, temperature Rate 4 steps/second Trip detect Continuity or voltage (continuity detection not available when sourcing current) Loop power function Voltage Selectable, 26 V Accuracy 10%, 18 V minimum at 22 mA Maximum current 25 mA, short circuit protected Maximum input voltage 50 V DC Step functions Source functions Voltage, current, resistance, frequency, temperature Manual step Selectable step, change with arrow buttons Autostep Fully programmable for function, start delay, stepvalue, time per step, repeat Environmental Specifications Operating temperature -10°C to 50°C Storage temperature -20°C to 60°C Dust/water resistance Meets IP52, IEC 529 Operating altitude 3000 m above mean sea level (9842 ft) Safety Specifications Agency approvals CAN/CSA C22.2 No 1010.1-92, ASNI/ISA S82.01-1994, UL3111, and EN610-1:1993 Mechanical and General Specifications Size 136 x 245 x 63 mm (5.4 x 9.6 x 2.5 in) Weight 1.2 kg (2.7 lb) Batteries Internal Battery Pack Li-ion: 7.2 V, 4400 mAh, 30 Wh Battery life &gt, 8 hours typical Battery replacement Via snap-shut door without opening calibrator, no tools required Side port connections Pressure module connector USB Connector to interface to your PC Connection for optional battery charger/eliminator Data storage capacity 1 week of calibration procedures results 90 day specifications The standard specification interval for the 750 Series are 1 and 2 years. Typical 90 day measurement and source accuracy can be estimated by dividing the one year % of reading or % of output specifications by 2. Floor specifications, expressed as % of full scale or counts or ohms remain constant. Temperature, Resistance Temperature Detectors Degrees or % of reading Type (α) Range °C Measure °C1 1 year 2 year 100 Ω Pt (385) -200 to 100 0.07°C 0.14°C 100 to 800 0.02% 0.05°C 0.04% 0.10°C 200 Ω Pt (385) -200 to 100 0.07°C 0.14°C 100 to 630 0.02% 0.05°C 0.04% 0.10°C 500 Ω Pt (385) -200 to 100 0.07°C 0.14°C 100 to 630 0.02% 0.05°C 0.04% 0.10°C 1000 Ω Pt (385) -200 to 100 0.07°C 0.14°C 100 to 630 0.02% 0.05°C 0.04% 0.10°C 100 Ω Pt (3916) -200 to 100 0.07°C 0.14°C 100 to 630 0.02% 0.05°C 0.04% 0.10°C 100 Ω Pt (3926) -200 to 100 0.08°C 0.16°C 100 to 630 0.02% 0.06°C 0.04% 0.12°C 10 Ω Cu (427) -100 to 260 0.2°C 0.4°C 120 Ω Ni (672) -80 to 260 0.1°C 0.2°C Source current Source…

  • Fluke 754

    $4.292

    Fluke 754 Overview Youre going to love what weve done with your calibrator. The 754 is everything you needed and wished for in the 744 and more! HART communication capability is combined to deliver an integrated communicating calibrator. This rugged, reliable tool is ideal for calibrating, maintaining, and troubleshooting HART and other instrumentation. The 754 does the work of several tools sourcing, simulating and measuring pressure, temperature, and electrical signals in one rugged, hand-held device. Youll fall in love with the new improved graphical screen, Li-Ion battery for longer life, USB port and new accessories to complete the package. For documentation, the 754 automates calibration procedures and captures your data. And, of course, it helps you meet rigorous standards like ISO 9000, FDA, EPA and OSHA regulations. HART Capabilities The 754 is designed to take on nearly all the day-to-day tasks you now perform with a separate communicator. In fact, it offers most of the communication capabilities of a HART communicator. Each Fluke 754 Includes Three sets of stackable test leads Three sets of TP220 test probes with three sets of extended tooth alligator clips Two sets AC280 hook clips BP7240 Li-ion battery pack BC7240 battery charger C799 field soft case USB communication cable Getting started guide Instruction manual on CDROM NIST traceable certificate of calibration DPCTrack™ 2 sample software HART communication cable > Measurement Accuracy Voltage DC Range/Resolution 1 Year 2 Years 100.000 mV 0.02% 0.005 mV 0.03% 0.005 mV 3.00000 V 0.02% 0.00005 V 0.03% 0.00005 V 30.0000 V 0.02% 0.0005 V 0.03% 0.0005 V 300.00 V 0.05% 0.05 V 0.07% 0.05 V Voltage AC 3.000 V (40 Hz to 500 Hz) / 0.001 V 0.5% 0.002 V 1.0% 0.004 V 30.00 V (40 Hz to 500 Hz) / 0.01 V 0.5% 0.02 V 1.0% 0.04 V 300.0 V (40 Hz to 500 Hz) / 0.1 V 0.5% 0.2 V 1.0% 0.2 V Current DC 30.000 mA 0.01% 5 uA 0.015% 7 uA 110.00 mA 0.01% 20 uA 0.015% 30 uA Resistance 10.000 Ω 0.05% 50 mΩ 0.07% 70 mΩ 100.00 Ω 0.05% 50 mΩ 0.07% 70 mΩ 1.0000 kΩ 0.05% 500 mΩ 0.07% 0.5 Ω 10.000 kΩ 0.1% 10 Ω 0.15% 15 Ω Frequency 1.00 to 110.00 Hz / 0.01 Hz 0.05 Hz 110.1 to 1100.0 Hz / 0.1 Hz 0.5 Hz 1.101 to 11.000 kHz / 0.001 kHz 0.005 kHz 11.01 to 50.00 kHz / 0.01 kHz 0.05 kHz Source Accuracy 1 Year 2 Years Voltage DC 100.000 mV 0.01% 0.005 mV 0.015% 0.005 mV 1.00000 V 0.01% 0.00005 V 0.015% 0.0005 V 15.0000 V 0.01% 0.0005 V 0.015% 0.0005 V Current DC 22.000 mA (source) 0.01% 0.003 mA 0.02% 0.003 mA Current sink (simulate) 0.02% 0.007 mA 0.04% 0.007 mA Resistance 10.000 Ω 0.01% 10 mΩ 0.015% 15 mΩ 100.00 Ω 0.01% 20 mΩ 0.015% 30 mΩ 1.0000 kΩ 0.02% 0.2 Ω 0.03% 0.3 Ω 10.000 kΩ 0.02% 3 Ω 0.03% 5 Ω Frequency 0.1 to 10.99 Hz 0.01 Hz 0.01 to 10.99 Hz 0.01 Hz 11.00 to 109.99 Hz 0.1 Hz 110.0 to 1099.9 Hz 0.1 Hz 1.100 to 21.999 kHz 0.002 kHz 22.000 to 50.000 kHz 0.005 kHz Technical Data Data log functions Measure functions Voltage, current, resistance, frequency, temperature, pressure Reading rate 1, 2, 5, 10, 20, 30, or 60 readings/minute Maximum record length 8000 readings (7980 for 30 or 60 readings/minute) Ramp functions Source functions Voltage, current, resistance, frequency, temperature Rate 4 steps/second Trip detect Continuity or voltage (continuity detection not available when sourcing current) Loop power function Voltage Selectable, 26 V Accuracy 10%, 18 V minimum at 22 mA Maximum current 25 mA, short circuit protected Maximum input voltage 50 V DC Step functions Source functions Voltage, current, resistance, frequency, temperature Manual step Selectable step, change with arrow buttons Autostep Fully programmable for function, start delay, stepvalue, time per step, repeat Environmental Specifications Operating temperature -10°C to 50°C Storage temperature -20°C to 60°C Dust/water resistance Meets IP52, IEC 529 Operating altitude 3000 m above mean sea level (9842 ft) Safety Specifications Agency approvals CAN/CSA C22.2 No 1010.1-92, ASNI/ISA S82.01-1994, UL3111, and EN610-1:1993 Mechanical and General Specifications Size 136 x 245 x 63 mm (5.4 x 9.6 x 2.5 in) Weight 1.2 kg (2.7 lb) Batteries Internal Battery Pack Li-ion: 7.2V,4400mAh, 30 Wh Battery life &gt,8 hours typical Battery replacement Replace without opening calibrator, no tools required Side port connections Pressure module connector USB Connector to interface to your PC Digital instrument (HART) connector Connection for optional battery charger/eliminator Data storage capacity 1 week of calibration procedures results 90 day specifications The standard specification interval for the 750 Seriesare 1 and 2 years. Typical 90 day measurement and source accuracy can be estimated by dividing the one year % of reading or % of output specifications by 2. Floor specifications, expressed as % of full scale or counts or ohms remain constant. Temperature, Resistance Temperature Detectors Degrees or % of reading Type (α) Range °C Measure °C1 1 year 2 year 100 Ω Pt (385) -200 to 100 0.07°C 0.14°C 100 to 800 0.02% 0.05°C 0.04% 0.10°C 200 Ω Pt (385) -200 to 100 0.07°C 0.14°C 100 to 630 0.02% 0.05°C 0.04% 0.10°C 500 Ω Pt (385) -200 to 100 0.07°C 0.14°C 100 to 630 0.02% 0.05°C 0.04% 0.10°C 1000 Ω Pt (385) -200 to 100 0.07°C 0.14°C 100 to 630 0.02% 0.05°C 0.04% 0.10°C 100 Ω Pt (3916) -200 to 100 0.07°C 0.14°C 100 to 630 0.02% 0.05°C 0.04% 0.10°C 100 Ω Pt (3926) -200 to 100 0.08°C 0.16°C 100 to 630 0.02% 0.06°C 0.04% 0.12°C 10 Ω Cu (427) -100 to 260 0.2°C 0.4°C 120 Ω Ni (672) -80 to 260 0.1°C 0.2°C Source current Source °C Allowable current2 1 year 2 year 1 mA 0.05°C 0.10°C 0.1 mA to 10 mA 0.0125% 0.04°C 0.025% 0.08°C 500 μA 0.06°C 0.12°C 0.1 mA to 1 mA 0.017% 0.05°C 0.034% 0.10°C 250 μA 0.06°C 0.12°C 0.1 mA to 1 mA 0.017% 0.05°C 0.034% 0.10°C 150 μA 0.06 C 0.12 C…

  • Fluke 754 VIP Kit 1

    $4.292

    Flukes next generation Documenting, Multifunction Calibrator improving upon the popular 74X Series. Exclusive VIP Kit includes FREE Fluke 113 Utility Multimeter, FREE T/C Lead Set, FREE Leatherman PST Tool, FREE Li-ion Battery Pack for Fluke 753 and 754, FREE Pelican Carrying Case, FREE 128 Pack of Green Calibration Labels. Overview You’re going to love what we’ve done with your calibrator. The 754 is everything you needed and wished for in the 744 and more! HART communication capability is combined to deliver an integrated communicating calibrator. This rugged, reliable tool is ideal for calibrating, maintaining, and troubleshooting HART and other instrumentation. The 754 does the work of several tools sourcing, simulating and measuring pressure, temperature, and electrical signals in one rugged, hand-held device. You’ll fall in love with the new improved graphical screen, Li-Ion battery for longer life, USB port and new accessories to complete the package. For documentation, the 754 automates calibration procedures and captures your data. And, of course, it helps you meet rigorous standards like ISO 9000, FDA, EPA and OSHA regulations. HART Capabilities The 754 is designed to take on nearly all the day-to-day tasks you now perform with a separate communicator. In fact, it offers most of the communication capabilities of a HART communicator. Save over $624 with the Fluke 754 VIP Kit. Limited Time Offer. FREE Fluke 113 Utility Multimeter (113) FREE T/C Lead Set (22171T) FREE Leatherman PST Tool (80141TL) FREE Li-ion Battery Pack for Fluke 753 and 754 (BP7240) FREE Pelican Carrying Case (1500-C) FREE 128 Pack of Green Calibration Labels Measure volts, mA, RTDs, thermocouples, frequency, and ohms to test sensors, transmitters and other instruments Source/simulate volts, mA, thermocouples , RTDs, frequency, ohms, and pressure to calibrate transmitters Power transmitters during test using loop supply with simultaneous mA measurement Measure/source pressure using any of 29 Fluke pressure modules Advanced features like autostep, custom units, user entered values during test, one-point and two-point switch testing, square root DP flow testing, programmable measurement delay and more Includes HART communication for adjusting and testing HART smart transmitters. Includes the new C799 Field soft case Three-year warranty > Each Unit Includes Free Fluke 113 DMM (must call to add calibration for this item) Free Leatherman Tool Free Pelican 1500 Case Free T/C Lead Free Li-Ion Battery Pack Free Calibration Labels Three sets of stackable test leads Three sets of TP220 test probes with three sets of “extended tooth” alligator clips Two sets AC280 hook clips BP7240 Li-ion battery pack BC7240 battery charger C799 field soft case USB communication cable Getting started guide Instruction manual on CDROM NIST traceable certificate of calibration DPCTrack™ 2 sample software HART communication cable > Measurement Accuracy Voltage DC Range/Resolution 1 Year 2 Years 100.000 mV 0.02% 0.005 mV 0.03% 0.005 mV 3.00000 V 0.02% 0.00005 V 0.03% 0.00005 V 30.0000 V 0.02% 0.0005 V 0.03% 0.0005 V 300.00 V 0.05% 0.05 V 0.07% 0.05 V Voltage AC 3.000 V (40 Hz to 500 Hz) / 0.001 V 0.5% 0.002 V 1.0% 0.004 V 30.00 V (40 Hz to 500 Hz) / 0.01 V 0.5% 0.02 V 1.0% 0.04 V 300.0 V (40 Hz to 500 Hz) / 0.1 V 0.5% 0.2 V 1.0% 0.2 V Current DC 30.000 mA 0.01% 5 uA 0.015% 7 uA 110.00 mA 0.01% 20 uA 0.015% 30 uA Resistance 10.000 Ω 0.05% 50 mΩ 0.07% 70 mΩ 100.00 Ω 0.05% 50 mΩ 0.07% 70 mΩ 1.0000 kΩ 0.05% 500 mΩ 0.07% 0.5 Ω 10.000 kΩ 0.1% 10 Ω 0.15% 15 Ω Frequency 1.00 to 110.00 Hz / 0.01 Hz 0.05 Hz 110.1 to 1100.0 Hz / 0.1 Hz 0.5 Hz 1.101 to 11.000 kHz / 0.001 kHz 0.005 kHz 11.01 to 50.00 kHz / 0.01 kHz 0.05 kHz Source Accuracy 1 Year 2 Years Voltage DC 100.000 mV 0.01% 0.005 mV 0.015% 0.005 mV 1.00000 V 0.01% 0.00005 V 0.015% 0.0005 V 15.0000 V 0.01% 0.0005 V 0.015% 0.0005 V Current DC 22.000 mA (source) 0.01% 0.003 mA 0.02% 0.003 mA Current sink (simulate) 0.02% 0.007 mA 0.04% 0.007 mA Resistance 10.000 Ω 0.01% 10 mΩ 0.015% 15 mΩ 100.00 Ω 0.01% 20 mΩ 0.015% 30 mΩ 1.0000 kΩ 0.02% 0.2 Ω 0.03% 0.3 Ω 10.000 kΩ 0.02% 3 Ω 0.03% 5 Ω Frequency 0.1 to 10.99 Hz 0.01 Hz 0.01 to 10.99 Hz 0.01 Hz 11.00 to 109.99 Hz 0.1 Hz 110.0 to 1099.9 Hz 0.1 Hz 1.100 to 21.999 kHz 0.002 kHz 22.000 to 50.000 kHz 0.005 kHz Technical Data Data log functions Measure functions Voltage, current, resistance, frequency, temperature, pressure Reading rate 1, 2, 5, 10, 20, 30, or 60 readings/minute Maximum record length 8000 readings (7980 for 30 or 60 readings/minute) Ramp functions Source functions Voltage, current, resistance, frequency, temperature Rate 4 steps/second Trip detect Continuity or voltage (continuity detection not available when sourcing current) Loop power function Voltage Selectable, 26 V Accuracy 10%, 18 V minimum at 22 mA Maximum current 25 mA, short circuit protected Maximum input voltage 50 V DC Step functions Source functions Voltage, current, resistance, frequency, temperature Manual step Selectable step, change with arrow buttons Autostep Fully programmable for function, start delay, stepvalue, time per step, repeat Environmental Specifications Operating temperature -10°C to 50°C Storage temperature -20°C to 60°C Dust/water resistance Meets IP52, IEC 529 Operating altitude 3000 m above mean sea level (9842 ft) Safety Specifications Agency approvals CAN/CSA C22.2 No 1010.1-92, ASNI/ISA S82.01-1994, UL3111, and EN610-1:1993 Mechanical and General Specifications Size 136 x 245 x 63 mm (5.4 x 9.6 x 2.5 in) Weight 1.2 kg (2.7 lb) Batteries Internal Battery Pack Li-ion: 7.2V,4400mAh, 30 Wh Battery life &gt,8 hours typical Battery replacement Replace without opening calibrator, no tools required Side port connections Pressure module connector USB Connector to interface to your PC Digital instrument (HART) connector Connection for optional battery charger/eliminator Data storage capacity 1 week of calibration procedures results 90 day specifications The standard specification interval for the 750 Seriesare 1 and 2 years. Typical 90 day measurement and source accuracy can be estimated…

  • Fluke 754/154 BU

    $5.557

    The Fluke 154 bundled with the Fluke 754 offers full HART support for calibration, troubleshooting and commissioning Automatically documents test results for upload to software Multifunction calibration mA, Pressure, Temperature, Frequency Absolute Maximum Operating Voltage: 0.01% mA Multifunction mA, Pressure, Temperature, Frequency Supports multiple software packages including DPCTrack2 and ProCalV5 > Fluke 754 Overview You’re going to love what we’ve done with your calibrator. The 754 is everything you needed and wished for in the 744 and more! HART communication capability is combined to deliver an integrated communicating calibrator. This rugged, reliable tool is ideal for calibrating, maintaining, and troubleshooting HART and other instrumentation. The 754 does the work of several tools sourcing, simulating and measuring pressure, temperature, and electrical signals in one rugged, hand-held device. You’ll fall in love with the new improved graphical screen, Li-Ion battery for longer life, USB port and new accessories to complete the package. For documentation, the 754 automates calibration procedures and captures your data. And, of course, it helps you meet rigorous standards like ISO 9000, FDA, EPA and OSHA regulations. HART Capabilities The 754 is designed to take on nearly all the day-to-day tasks you now perform with a separate communicator. In fact, it offers most of the communication capabilities of a HART communicator. Each Fluke 754 Includes Three sets of stackable test leads Three sets of TP220 test probes with three sets of “extended tooth” alligator clips Two sets AC280 hook clips BP7240 Li-ion battery pack BC7240 battery charger C799 field soft case USB communication cable Getting started guide Instruction manual on CDROM NIST traceable certificate of calibration DPCTrack™ 2 sample software HART communication cable > The 154 puts HART device configuration at your fingertips. An Android™ based tablet user interface makes HART configuration easy. The external wireless modem allows you to connect the modem to the transmitter being tested so you can communicate to the device remotely. HART transmitters can often be found in confined spaces that are difficult to access, or are out of reach. The Fluke 154 helps reduce the need to stand right next to the device being tested or configured so you can work from a safer, more convenient location. Fluke 154 Highlights Full HART Device Description (DD) of all HART devices Configure HART devices Perform HART trim on HART devices when used with a Fluke 750, or 720 series calibrator Monitor device PV, SV, TV, QV and other measured HART variables Quarterly HART DD updates for free Convenient wireless connectivity to HART modem Easy to use, fast connect and view HART data Store HART device configurations Long range wireless communication up to 250 feet Wireless HART Modem: Includes configurable connection cable that accepts either the hook clips for connecting to wires or the extended tooth alligator clips designed to connect to transmitter connection screw heads. Rechargeable lithium-ion battery lasts easily for several days of HART device configuration and testing activities. Rugged enclosure and test lead set designed for process environments Store device configurations: Store HART device configurations in ASCII or PDF file configurations. HART support: Complete access to all features of the HART devices DD including methods. Meets HART physical layer specification: HCF_SPEC-54 DD updates: Download free DD updates from Fluke.com for 3-years. Updates available when DD updates released from the HART FieldComm group (approximately four times a year). Hard side case: Protects and stores tablet, modem, test leads and connection cable in a lightweight durable tote that is easy to carry. > Each Fluke 154 Includes Tablet, tablet charger and USB micro-cable Fluke HART App. (installed), HART modem USB mini-cable, proof of purchase for product activation Hook test clips Alligator clips Magnetic hanging strap Case Manual installed on tablet Three-year warranty

  • Fluke 754/750SW BU

    $5.557

    Overview Youre going to love what weve done with your calibrator. The 754 is everything you needed and wished for in the 744 and more! HART communication capability is combined to deliver an integrated communicating calibrator. This rugged, reliable tool is ideal for calibrating, maintaining, and troubleshooting HART and other instrumentation. The 754 does the work of several tools sourcing, simulating and measuring pressure, temperature, and electrical signals in one rugged, hand-held device. Youll fall in love with the new improved graphical screen, Li-Ion battery for longer life, USB port and new accessories to complete the package. For documentation, the 754 automates calibration procedures and captures your data. And, of course, it helps you meet rigorous standards like ISO 9000, FDA, EPA and OSHA regulations. HART Capabilities The 754 is designed to take on nearly all the day-to-day tasks you now perform with a separate communicator. In fact, it offers most of the communication capabilities of a HART communicator. Measure volts, mA, RTDs, thermocouples, frequency, and ohms to test sensors, transmitters and other instruments Source/simulate volts, mA, thermocouples , RTDs, frequency, ohms, and pressure to calibrate transmitters Power transmitters during test using loop supply with simultaneous mA measurement Measure/source pressure using any of 29 Fluke pressure modules Advanced features like autostep, custom units, user entered values during test, one-point and two-point switch testing, square root DP flow testing, programmable measurement delay and more Includes HART communication for adjusting and testing HART smart transmitters. Includes the new C799 Field soft case Three-year warranty > Each Unit Includes DPC/TRACK2 Software Three sets of stackable test leads Three sets of TP220 test probes with three sets of “extended tooth” alligator clips Two sets AC280 hook clips BP7240 Li-ion battery pack BC7240 battery charger C799 field soft case USB communication cable Getting started guide Instruction manual on CDROM NIST traceable certificate of calibration HART communication cable > Measurement Accuracy Voltage DC Range/Resolution 1 Year 2 Years 100.000 mV 0.02% 0.005 mV 0.03% 0.005 mV 3.00000 V 0.02% 0.00005 V 0.03% 0.00005 V 30.0000 V 0.02% 0.0005 V 0.03% 0.0005 V 300.00 V 0.05% 0.05 V 0.07% 0.05 V Voltage AC 3.000 V (40 Hz to 500 Hz) / 0.001 V 0.5% 0.002 V 1.0% 0.004 V 30.00 V (40 Hz to 500 Hz) / 0.01 V 0.5% 0.02 V 1.0% 0.04 V 300.0 V (40 Hz to 500 Hz) / 0.1 V 0.5% 0.2 V 1.0% 0.2 V Current DC 30.000 mA 0.01% 5 uA 0.015% 7 uA 110.00 mA 0.01% 20 uA 0.015% 30 uA Resistance 10.000 Ω 0.05% 50 mΩ 0.07% 70 mΩ 100.00 Ω 0.05% 50 mΩ 0.07% 70 mΩ 1.0000 kΩ 0.05% 500 mΩ 0.07% 0.5 Ω 10.000 kΩ 0.1% 10 Ω 0.15% 15 Ω Frequency 1.00 to 110.00 Hz / 0.01 Hz 0.05 Hz 110.1 to 1100.0 Hz / 0.1 Hz 0.5 Hz 1.101 to 11.000 kHz / 0.001 kHz 0.005 kHz 11.01 to 50.00 kHz / 0.01 kHz 0.05 kHz Source Accuracy 1 Year 2 Years Voltage DC 100.000 mV 0.01% 0.005 mV 0.015% 0.005 mV 1.00000 V 0.01% 0.00005 V 0.015% 0.0005 V 15.0000 V 0.01% 0.0005 V 0.015% 0.0005 V Current DC 22.000 mA (source) 0.01% 0.003 mA 0.02% 0.003 mA Current sink (simulate) 0.02% 0.007 mA 0.04% 0.007 mA Resistance 10.000 Ω 0.01% 10 mΩ 0.015% 15 mΩ 100.00 Ω 0.01% 20 mΩ 0.015% 30 mΩ 1.0000 kΩ 0.02% 0.2 Ω 0.03% 0.3 Ω 10.000 kΩ 0.02% 3 Ω 0.03% 5 Ω Frequency 0.1 to 10.99 Hz 0.01 Hz 0.01 to 10.99 Hz 0.01 Hz 11.00 to 109.99 Hz 0.1 Hz 110.0 to 1099.9 Hz 0.1 Hz 1.100 to 21.999 kHz 0.002 kHz 22.000 to 50.000 kHz 0.005 kHz Technical Data Data log functions Measure functions Voltage, current, resistance, frequency, temperature, pressure Reading rate 1, 2, 5, 10, 20, 30, or 60 readings/minute Maximum record length 8000 readings (7980 for 30 or 60 readings/minute) Ramp functions Source functions Voltage, current, resistance, frequency, temperature Rate 4 steps/second Trip detect Continuity or voltage (continuity detection not available when sourcing current) Loop power function Voltage Selectable, 26 V Accuracy 10%, 18 V minimum at 22 mA Maximum current 25 mA, short circuit protected Maximum input voltage 50 V DC Step functions Source functions Voltage, current, resistance, frequency, temperature Manual step Selectable step, change with arrow buttons Autostep Fully programmable for function, start delay, stepvalue, time per step, repeat Environmental Specifications Operating temperature -10°C to 50°C Storage temperature -20°C to 60°C Dust/water resistance Meets IP52, IEC 529 Operating altitude 3000 m above mean sea level (9842 ft) Safety Specifications Agency approvals CAN/CSA C22.2 No 1010.1-92, ASNI/ISA S82.01-1994, UL3111, and EN610-1:1993 Mechanical and General Specifications Size 136 x 245 x 63 mm (5.4 x 9.6 x 2.5 in) Weight 1.2 kg (2.7 lb) Batteries Internal Battery Pack Li-ion: 7.2V,4400mAh, 30 Wh Battery life &gt,8 hours typical Battery replacement Replace without opening calibrator, no tools required Side port connections Pressure module connector USB Connector to interface to your PC Digital instrument (HART) connector Connection for optional battery charger/eliminator Data storage capacity 1 week of calibration procedures results 90 day specifications The standard specification interval for the 750 Seriesare 1 and 2 years. Typical 90 day measurement and source accuracy can be estimated by dividing the one year % of reading or % of output specifications by 2. Floor specifications, expressed as % of full scale or counts or ohms remain constant. Temperature, Resistance Temperature Detectors Degrees or % of reading Type (α) Range °C Measure °C1 1 year 2 year 100 Ω Pt (385) -200 to 100 0.07°C 0.14°C 100 to 800 0.02% 0.05°C 0.04% 0.10°C 200 Ω Pt (385) -200 to 100 0.07°C 0.14°C 100 to 630 0.02% 0.05°C 0.04% 0.10°C 500 Ω Pt (385) -200 to 100 0.07°C 0.14°C 100 to 630 0.02% 0.05°C 0.04% 0.10°C 1000 Ω Pt (385) -200 to 100 0.07°C 0.14°C 100 to 630 0.02% 0.05°C 0.04% 0.10°C 100 Ω Pt (3916) -200 to 100 0.07°C 0.14°C 100 to 630 0.02% 0.05°C 0.04% 0.10°C…

  • Fluke Calibration 4180 VIP KIT

    $5.301

    FREE Carrying Case FREE Fluke 561 IR Thermometer True infrared traceability and a six-inch target make these the most accurate and versatile gray bodies on the market Temperature Range: –15 °C to 120 °C Big Six-Inch Target Accommodates all Manufacturers Recommended Calibration Geometries Built-in Support for all Fluke and aytek 8-14 mm Infrared Thermometers First-of-its-Kind Thermometer Emissivity atching Accredited Radiometric (Infrared) Calibration Reports > Each Unit Includes FREE Carrying Case FREE Fluke 561 IR Thermometer Accredited contact and infrared calibration reports Target cover User’s Guide Getting started guide 9930 Interfaceit Software with user’s guide

  • Fluke Calibration 4181

    $3.727

    True infrared traceability and a six-inch target make these the most accurate and versatile gray bodies on the market Temperature Range: 35 °C to 500 °C Big Six-Inch Target Accommodates all Manufacturers Recommended Calibration Geometries Built-in Support for all Fluke and Raytek 8-14 mm Infrared Thermometers First-of-its-Kind Thermometer Emissivity atching Accredited Radiometric (Infrared) Calibration Reports > Each Unit Includes Accredited contact and infrared calibration reports Target cover User’s Guide Getting started guide 9930 Interfaceit Software with user’s guide