Showing 64–72 of 176 results
-
$3.052
Insulation and AC/DC continuous voltage withstand testing Safety standards compliance testing Stores up to 10 sets of test conditions (10 each for insulation and voltage withstand) Zero-V Switching (voltage withstand testing) Electrical Discharge function (DC voltage withstand, insulation testing) Automated testing support Interlock Protect function Remote controllable > Each Unit Includes 1 9615 H.V. Test Lead, High voltage side 1 9615 H.V. Test Lead, Return 1 Power cord 1 Spare fuse
-
$1.692
Measurement items Low resistance, AC 4-terminal method Generator section Current generator principle: PWM constant current control, Current setting range: 3.0 A to 31.0 A (0.1 A resolution), into 0.1 Ohm load, Maximum output power: 130 VA*1 (at output terminals) *1 Subject to derating according to ambient temperature (80 % at 40 °C) Frequency: 50 Hz or 60 Hz sine wave, Soft start function: Apply current only after checking load connection Monitor section Resistance measurement: 0 to 1.800 Ohm (0.001 Ohm resolution), Accuracy: ±2 % rdg. ±4 dgt. (after zero-adjust), Current monitoring range: 0 to 35.0 A AC (0.1 A resolution), Monitoring cycle: 2 times/second Other functions Timer setting: Counts down time after start until preset time, or shows elapsed time after start, Setting range: 0.5 to 999 second, Comparator: Pass/Fail evaluation using preset upper/lower limit, I/O output, Memory function: max. 20 settings (with save/load) Display Fluorescent tube digital display Power supply 100 to 120 V, 200 to 240 V AC (auto-switching), 50/60 Hz Dimensions, mass 320 mm(12.60 in)W × 90 mm(3.54 in)H × 263 mm(10.35 in)D, 7 kg (246.9 oz) > Each Unit Includes Power cord Spare fuse Shorting bar(2)
-
$1.692
3159-01 Insulation/ Withstanding Tester (120VAC) Perform insulation resistance and withstand voltage testing in a single series Insulation and voltage withstand testing Safety standards compliance testing Stores up to 10 sets of test conditions (10 each for insulation and voltage withstand) Voltage comparator functions (voltage withstand testing) Zero-V Switching (voltage withstand testing) Electrical Discharge function (insulation testing) Automated testing support Interlock Protect function Remote controllable Power Supply: 120 V AC, 50/60 Hz
-
$1.881
Insulation and voltage withstand testing Safety standards compliance testing Stores up to 10 sets of test conditions (10 each for insulation and voltage withstand) Voltage comparator functions (voltage withstand testing) Zero-V Switching (voltage withstand testing) Electrical Discharge function (insulation testing) Automated testing support Interlock Protect function Remote controllable
-
$193
3-range testing voltage, Insulation meter Continuity check, 3? range via 200mA testing Luminous scale Check for live circuits Check for the battery status Testing voltage 250 V DC, 500 V DC, 1000 V DC Rated resistance 100 MΩ, 100 MΩ, 4000 MΩ Accuracy 1st effective measuring range ±5 % of indicated value 0.05 to 50 MΩ, ±5 % of indicated value 2 to 1000 MΩ Rated measurement current 1 mA Low resistance 3 Ω range, ±0.09 Ω accuracy, 200 mA DC measuring current, 4.1 to 6.9 V open-circuit voltage AC voltage range 0 to 600 V (50/60 Hz), ±5 % of maximum scale value accuracy, 100 kΩ or more input resistance Other functions Luminous scale, Battery status check, Live circuit check Power consumption AA alkaline (LR6) battery × 4, Continuous use: 20 hours (at 500 V range, no load) Dimensions, mass 159 mm (6.26 in)W × 177 mm (6.97 in)H × 53 mm (2.09 in)D, 610 g (21.5 oz), (including battery, not including test lead) > Each Unit Includes Test lead Operation manual Shoulder strap AA alkaline battery (LR6)
-
$444
DC Bias Voltage Unit for IM series LCR Four measuring results can be simultaneously displayed Four sampling rates from 20 ms selectable Test parameters memory for up to 30 settings incl. comparator values High resolution (5 full digits) and basic accuracy of ±0.08% Simple operation with touch-screen Up to 5 sequential measurements definable Instrument control and data evaluation via EXT. I/O RS232C, GP-IB and printer optional
-
$444
DC Bias Current Unit for IM Series LCR Direct-coupled, 40Hz ~ 2MHz, maximum input current DC 2A (maximum applied voltage DC ± 40V) In use, the constant current source external you will need a 9269-10
-
$5.553
Hioki LCR Meters and Impedance Analyzers range from 1mHz to 3GHz devices to suit a wide range of applications in the testing of electronic components. The IM3570 is ideal for use in applications requiring low-ESR measurement on the order of several milliohms, for example testing of functional polymer capacitors, due to its superior low-impedance repeatability. LCR, DCR, sweep, and continuous measurement with high-speed testing in a single unit Maximum test speeds of 1.5ms (1 kHz) and 0.5ms (100kHz) in LCR mode High basic accuracy of Z parameter: ±0.08% Ideal for testing the resonance characteristics of piezoelectric elements, C-D and low ESR measurement of functional polymer capacitors, DCR and L-Q measurement of inductors (coils and transformers) Perform frequency sweeps, level sweeps, and time interval measurements in analyzer mode Support for high-speed switching of measurement conditions
-
$166
Single range testing voltage 500 V, Insulation meter up to 100 mega-ohm Built tough to withstand a 1-meter drop onto a concrete floor Bright LED luminous scale Check for live circuits and for the battery status Hard case in a body, quick and easy storage without disconnecting the leads