$0
Earth resistance and soil resistivity with 2/3/4 pole method Stackless earth ground resistance (with T2100 optional accessory) Power Analysis, Harmonic analysis up to 25th Continuity of protection conductors with 200mA Built-in WiFi interface to connect to iOS and Android devices USB interface to connect to the PC Color touch-screen display Help on-line Internal memory and Cloud Storage (trough iOS or Android device) Rechargeable NiMH batteries (external battery charger) > Each Unit Includes Kit Includes: MacrotestG1 VA504 T2100
-
$1.829
Earth resistance and soil resistivity with 2/3/4 pole method Stackless earth ground resistance (with T2100 optional accessory) Power Analysis, Harmonic analysis up to 25th Insulation resistance with 50, 100, 250, 500,1000V DC Continuity of protection conductors with 200mA Built-in WiFi interface to connect to iOS and Android devices USB interface to connect to the PC Color touch-screen display Help on-line Internal memory and Cloud Storage (trough iOS or Android device) Rechargeable NiMH batteries (external battery charger) > Each Unit Includes Kit Includes: MacrotestG1 VA504 T2100
-
$303
Insulation Resistance measurement with 250, 500VDC Measurement range up to 1Gohm Automatic discharging object after test Continuity test of protective conductors with 200mA Auto calibration of test leads DC Voltage AC TRMS Voltage Automatic detection of AC/DC signals AC TRMS Current with optional external clamp AC TRMS Leakage current with optional external clamp Resistance Continuity test with buzzer Frequency with test leads Frequency with optional external clamp Phase sequence indication at 1 or 2 wires method Phase coincidence indication at 1 or 2 wires method MIN/MAX/AVG functions PEAK function with response time 1ms HOLD function Auto Power OFF > Each Unit Includes M72 KIT0075 : Set 2 cables with leads 2 alligator clips BORSA75 : Carrying bag ISO9000 calibration certificate User manual on CD-ROM Quick reference guide
-
$329
Continuity test of protective conductors with 200mA Insulation Resistance measurement with 250, 500VDC Trip-out time of RCDs type A, AC Standard Selectable test current, 30mA, 30x5mA, 100mA, 300mA RCD Ramp test Global Earth Resistance without RCD tripping Global Earth Resistance with 0.1_ resolution Automatic test of global earth resistance RDC test insulation test DC Voltage AC TRMS Voltage Automatic detection of AC/DC signals AC TRMS Current with optional external clamp AC TRMS Leakage current with optional external clamp Resistance Continuity test with buzzer Frequency with test leads Frequency with optional external clamp Phase sequence indication with 1 or 2 terminals Phase coincidence indication with 1 or 2 terminals MIN/MAX/AVG functions PEAK function with response time 1ms HOLD function Auto Power OFF > Each Unit Includes M74 KIT0075 : Set 2 cables with leads 2 alligator clips C2075 : Cable 2 wires with Shuko plug BORSA75 : Carrying bag ISO9000 calibration certificate User manual on CD-ROM Quick reference guide
-
$1.107
Earth resistance and soil resistivity with 2/3/4 pole method Stackless earth ground resistance (with T2100 optional accessory) Power Analysis, Harmonic analysis up to 25th Insulation resistance with 50, 100, 250, 500,1000V DC Continuity of protection conductors with 200mA Built-in WiFi interface to connect to iOS and Android devices USB interface to connect to the PC Color touch-screen display Help on-line Internal memory and Cloud Storage (trough iOS or Android device) Rechargeable NiMH batteries (external battery charger) > Each Unit Includes MarcoTest G2 PT400 : Touch pen KITGSC5 : Set 4 cables 4 alligator clips 2 test leads KITTERRNE : Set 4 cables 4 metal probes TOPVIEW2006 : Windows software optical/USB cable C2006 YABAT0003000 : NiMH rechargeable battery, type AA, 1.2V BORSA2051 : Soft carrying bag
-
$1.162
Continuity of protection conductors with 200mA Insulation resistance with 50, 100, 250, 500,1000V DC Type A, AC, and B general, selective, and delayed RCDs up to 1000mA Test on earth leakage relay RCDs (with RCDX10 optional accessory) Line/fault impedance with prospective short circuit current calculation High resolution line/fault impedance (with IMP57 optional accessory) Curve B, C, D, and K MCBs and type gG and aM fuses Selection of length, type, and insulation of the cable under test Selection of tripping time of the protection device under test Earth resistance and soil resistivity with auxiliary rods Earth ground resistance (with T2100 optional accessory) Non-trip earth loop impedance Phase sequence indication Voltage drop on main power lines Power Analysis, Harmonic analysis up to 25th Leakage current by means of the external transducer HT96U (optional) Environmental parameters (C/F, HR%, Lux) by means of optional probes > Each Unit Includes TFT display with touch-screen Help on-line Internal memory USB interface to connect to the PC Built-in WiFi interface to connect to iOS and Android devices Rechargeable NiMH batteries (external battery charger)
-
$541
Global Earth Resistance without RCD tripping Trip out time of RCDs type AC, A Standard and Selective Trip out current of RCDs type AC, A Standard and Selective up to 1A Loop Impedance P-P, P-N, P-PE Loop Impedance with high resolution (with IMP57 optional accessory) Prospective short circuit current Contact voltage Phase sequence indication Measure with remote probe (with PR400 optional accessory) Contextual help at display Internal memory Optical-USB interface with PC connection > Each Unit Includes C2033X : Cable 3 wires with Shuko plug BORSA75N : Soft carrying bag ISO9000 calibration certificate User manual on CD-ROM Quick reference guide
-
$243
Cat IV 600-Volt Checks new installations for proper insulation Checks existing installations and motor windings for breakdowns in insulation Hand-held insulation tester Two year warranty The Ideal 61-795 insulation tester checks new installations so you can properly insulate it Checks existing installations and motor windings for breakdowns in insulation
-
$341
Checks new and existing installations for proper insulation Performs maintenance checks on motor windings Measures earth-bond resistance Calculates PI and DAR automatically Stores values in memory for easy recall Tests voltages at 50/100/250/500/1000V Insulation Resistance Up to 20G ohm Earth Bond Resistance 0.01 ohm to 40.00k ohm > Each Unit Includes Carrying case