Showing 19–27 of 41 results
-
$7.939
MegaPulse 1.250-12.3P-1 500 ohm, EN 62052-11 Para. 7.3.2, 12.3kV 500 ohms. This tester is built to the requirements of IEC 60060-1 with a 500 ohm impedance. For Standards such as EN 62052-11, Clause 7.3.2 and VDE PM323E, this tester allows impulse testing to determine spacings in lieu of other requirements. This tester can perform to test parameters requiring surge voltages of up to 12kV. The MegaPulse 1.250-12.3 500 ohm is built specifically to conduct these tests. It uses our proprietary High Voltage relay, built to the requirements of IEC 65 Figure 7 b for robustness and complete compliance with the requirements. In addition, for automated testing, the MegaPulse 1.250-12.3 500 ohm is available with TestMinder P, our computer control and test reporting option. The MegaPulse is used with a general purpose oscilloscope for waveform capture and evaluation. The standard configuration outputs 12.3kV at 0.5J. Can optionally be configured with three additional 0.5J voltage points at 1500, 6000 and 8000 volts.
-
$5.459
UL 746E Section 19 covers requirements for conformal coatings used instead of electrical spacings to increase the dielectric withstand voltage between traces on a printed-wiring board. Paragraph 19.3 outlines a Voltage transient test to be applied to a specific test pattern allows testing to determine spacings. The Surge Generator circuit is specified in UL 746E, Figure 19.2 is contained in the MegaPulse 746E. One press of the MegaPulse 746E TRIGGER button conducts the test suite as described in UL 746E, Para. 19.3. See the schematic in the Datasheet section on this page. Note: Voltages 400V and over are certified to be in accordance with the tolerances of IEC 1180-1, Para. 6.2.2. Provided with external interlock control. In addition, for automated testing, the MegaPulse 746E is available with TestMinder, our computer control and test reporting option. Use with a 32 bit Windows computer. Provided with NIST Calibration Certificate good for one year. A2LA Calibration available. Output: In accordance with UL 746E, Para. 19.3, a-c. Voltage Rise Time: /- 30% (400V ). Voltage Fall Time: /- 20% (400V ). Source Impedance: 50ohm /- 10%. Source Energy: not defined. Mode of Operation: Automatic, stop with external interlock. Charge Time: <,60 sec. The MegaPulses are used with a general purpose oscilloscope for waveform capture and evaluation. The MEGAPULSE 746E is designed to test Conformal Coatings in accordance with UL 746E, Paragraph 19.3 at up to 6kV.
-
$6.891
The MegaPulse 1.250-12±2 ohm is our 12kV, 6kA combination tester, with a 30 second cycle time. It can produce a combination test waveform at 2 ohms from 500V to 12kV, in tolerance with EN 60060. For example, the MegaPulse 1.250/820-12±2 ohm Surge Tester is specifically designed to perform the Impulse Test on transient overvoltage limiting devices in accordance with EN 61010, Para. 14.9, Table 17 and Table 18. This tester can perform all the tests shown in Table 17 at either 2 or 12 ohms as shown in Table 18. The output is in accordance with the published waveform from 500-12000V peak (open and short circuit). The tests can be done with a 30 second or longer wait between pulses, well within the Standard requirement of 1 minute or less. A 12 ohm tap is provided for testing Category II devices in accordance with Table 18, in accordance with the Standard. The 12 ohm tap will be in accordance with the tolerances of the voltage waveform only, as allowed by the Standard. The MegaPulse 1.250/820-12±2 ohm is equipped with a relay allowing switch selected polarity output. With the switch selected polarity output, users may opt for computer control via our option TestMinder MegaPulse, or PLC guided operation with our Relay Isolated Control board. Some users may not need this level of automation in their testing, and we can accomodate them with our model MegaPulse 1.250/820-12 2 ohm. Polarity is changed by manually switching leads. Pos/neg polarity, grounded output, 500V min, 12 ohm tap, not for use with CDN. 30 sec duty cycle, <,30 sec. charge time. Outputs a combination waveform at 500 12kV, 2 ohms. Front panel switch allows waveform reversal (±2 ohm model only). 30 second pulse repeat rate. 12 ohm tap provided, in accordance with EN60060 (voltage waveform only). Can be controlled from PLC or LabView with Option RI (±2 ohm model only). Outputs up to 12000V peak. Virtual Impedance of 2/12 ohms. Available TestMinder for computer control of long test sequences (±2 ohm model only). Provided with NIST calibration good for one year, A2LA/17025 calibration available. 1 year warranty.
-
$11.200
The MegaPulse Biphasic P 360J/100 can be used to test products in research and production environments. The biphasic output pulse mimics the newest defibrillator output standard but allows more repeatability and faster pulsing than a defibrillator would. The output is stable and provides the required 360J power in a production test or continuous test environment. The available autotrigger control provides very repeatable outputs which makes testing results more meaningful. The MegaPulse 360J/100 is used to prove any part which would be subjected to defibrillator pulses. The biphasic output reversal timing can be configured at the factory for any timing desired within the pulse. Output power is also configurable upon request. Output voltage is approximately 2kV, with slight variances to meet the 360J power requirement. Output may be as high as 2040V in order to provide the power required. With the available 00-MPH Monophasic waveform option, the MegaPulse 360J can also output the truncated isolation waveform of AAMI DF-1, Figure A.2 for additional testing of defibrillator leads. Outputs a biphasic waveform containing 360J power for defibrillation parts testing. Microprocessor controlled wavform reversal for accurate, repeatable waveforms. Rated for continuous operation with one minute pulse times. Customer can specify any time in the waveform for the reversal point. Available autotrigger for extremely repeatable power output pulses. Available Monophasic truncated waveform in accordance with AAMI DF.1 Fig. A.2 (Isolation) for lead testing Available TestMinder for computer control of long test sequences 1 year warranty
-
$4.100
Up to 270V test voltage Microcontroller technologies, front panel voltage meter indicates test peak open circuit voltage and polarity. Output voltage and polarity are controlled manually from the front panel Ergonomically designed for safety, speed and efficiency Cables, manual and calibration certificate included External interlock disables HV output and defeats test when circuit is open Optional USB Testminder, computer control Optional Resistor network of Fig. 110 One year calibration cycle One year warranty
-
$4.125
Generates the waveform required by IEC 384, Annex A, for Surge voltage testing of capacitors. Designed with operator safety in mind: Set up the EUT to the right and behind the tester, and a right-handed operator will find himself standing to the left of the tester, allowing maximum separation. Theoretical graphs and actual graphs showing the output of your tester are included with each MegaPulse Capacitor Tester, allowing easy sanity checks and proof to visiting agency engineers of test setups. Optional 1000:1 BNC Oscilloscope output allows quick connections and easy evaluation of output waveforms. Reverse polarity waveforms available by pushing a button on the front panel. No need to change the test setup. Positive polarity indication minimizes errors. Front panel voltage meter shows residual voltage in charging circuit for safer operation. 1-year calibration cycle. All test leads included. 1 year warranty.
-
$5.754
Direct Joules readout on front panel after Energy Reduction Test. Increased accuracy in accordance with IEC 60601-2-25 and -2-27:2011 requirements. 20 second period between pulse delivery Increased signal generator voltage for -2-27 tests (Order Option SG). Integrated Pass/Fail reference for checking the equipment and test setup. Dry Capacitor delivers >,2.5M pulses at 20 second intervals. Integrated energy measurement, see demonstration video. USB Testminder, Computer Control. External interlock, disables HV output and defeats test when circuit is open. Ergonomically designed for safety, speed and efficiency. Front panel indicates polarity Output voltage and polarity are controlled manually on front panel or via TestLink. Cables, manual and calibration certificate included. One year calibration cycle. One year warranty.
-
$4.519
Up to 380V test Voltage Designed with operator safety in mind: Set up the EUT to the right and behind the tester, and a right-handed operator will find himself standing to the left of the tester, allowing maximum separation Theoretical graphs and actual graphs showing the output of your tester are included with each MegaPulse Defib Surge P, allowing easy sanity checks and proof to visiting agency engineers of test setups Microcontroller technologies, front panel voltage meter indicates test peak open circuit voltage and polarity Reverse polarity waveforms available by pushing a button on the front panel. No need to change the test setup. Positive polarity indication minimizes errors Front panel voltage meter shows residual voltage in charging circuit for safer operation 1-year calibration cycle All test leads included 1 year warranty
-
$5.092
Compliance West USA MegaPulse DF-1A.2, Surge Tester DF-1 Fig. A.2 waveform with truncation, USB TestMinder Surge Tester and IGBT switch The DF-1P Isolation surge Tester is designed to generate the waveform described in AAMI DF-1, Figure A.2., for the Lead Connector electrical isolation test in AAMI DF-1, Annex A. The test can be set to automatically conduct the first 490 cycles (500 ± 50 as shown in Standard) of the test, and then stop testing to allow laboratory personnel monitor the last 10 cycles in accordance with the Standard. Voltage and current BNC outputs make waveform analysis convenient. Generates the waveform required for the Current carrying Test, AAMI DF-1, Appendix B, and described in AAMI DF-1, Figure B.2. Designed with operator safety in mind: Set up the EUT to the right and behind the tester, and a right-handed operator will find himself standing to the left of the tester, allowing maximum separation. Theoretical graphs and actual graphs showing the output of your tester are included with each MegaPulse DF-1P, allowing easy sanity checks and proof to visiting agency engineers of test setups. BNC Oscilloscope outputs allows quick connection and easy evaluation of voltage and current output waveforms. Reverse polarity waveforms available by pushing a button on the front panel. No need to change the test setup. Positive polarity indication minimizes errors. TestMinder computer control allows automation of the required 490 cycles, then the operator can conduct the last 10 cycles in which the current waveform must be monitored. (Waveform capture is not provided). 1-year calibration cycle. All test leads included. 1 year warranty Current Duration: 18 mS Meter accuracy: ±5 % Operation temperature: 15-40 °C Relativity humidity range: 0-90 % Non condensing Standards: AAMI DF-1 App B, Figure B.2 Storage: No Warranty: 1 Year Calibration: 1 year ECCN number: 3B992 HTS/Schedule B: 9030.39.0100 Product Dimensions: 17 w x 17 L x 6 H