Showing 37–45 of 99 results

  • Hioki FT3151

    $273

    Earthing or grounding of electrical equipment is essential to maintain safety, protecting lives, as well as prevent damage to equipment. The FT3151 Analog EarthTester uses the AC phase differential system to measure earthing resistance, which assures that accurate measurements are unaffected by earth voltage and auxiliary earthing resistance. New innovate cord winders make clean up a breeze. CAT II 300 V Three-electrode method, Two-electrode method (Simple Measurement) Wide measurement range for 0 to 1150 Ω, based on EN standard Switchable measurement frequency to reduce the effects of power supply harmonics Dramatically faster setup: Comes with improved grounding rods and cord winders. > Each Unit Includes Auxiliary Earthing Rod L9840 (2 piece set) Measuring cable L9841 (alligator clip, black 4 m (13.12 ft)) Measurement Cable L9842-11 (yellow 10 m (32.81 ft), equipped with winder) Measurement Cable L9842-22 (red 20 m (65.62 ft), equipped with winder) LR6 (AA) Alkaline battery ×6 Carrying Case C0106 Instruction manual

  • Hioki FT6031-03

    $277

    Earthing or grounding of electrical equipment is essential to maintain safety, protecting lives, as well as prevent damage to equipment. The FT6031-03 is a IP67 dustproof and waterproof two- or three-pole ground resistance tester with large, easy-to-read display, highly sensitive earthing rods, and innovative cable winder that significantly reduces the amount of time needed to complete earth resistance tests. CAT IV 100 V, CAT III 150 V, CAT II 300 V IP67 protected – top of the industry Test all ground types from Class A to Class D with a single meter Wide 0 to 2000Ω measurement range Minimize cabling time with innovative earthing rods and cable winder Measurement system: Switchable between two- and three- electrode methods Measurement range: 20 Ω (0 to 20.00 Ω) 200 Ω (0 to 200.0 Ω) 2000 Ω (0 to 2000 Ω) > Accuracy: ±1.5 %rdg. ±8 dgt. ±1.5 %rdg. ±4 dgt. ±1.5 %rdg. ±4 dgt. > Earth voltage: 0 to 30.0 Vrms, Accuracy: ±2.3 %rdg. ±8 dgt. (50/60 Hz), ±1.3 %rdg. ±4 dgt. (DC) Dustproof and waterproof: IP65/IP67 (EN60529) Power supply: LR6 Alkaline battery ×4 Dimensions and mass: 185 mm (7.28 in)W × 111 mm (4.37 in)H × 44 mm (1.73 in)D, 570 g (20.1 oz) (including protector and batteries) > Each Unit Includes Auxiliary earthing rod L9840 (2 piece set) ×1 Measurement cable (black 4 m) L9841 ×1 Measurement cable (yellow 10 m, equipped with winder) L9842-11 ×1 Measurement cable (red 20 m, equipped with winder) L9842-22 ×1 Carrying case C0106 ×1 Protector ×1 LR6 Alkaline battery ×4 Instruction manual ×1

  • Hioki FT6380

    $718

    1.26 In. Jaw Window Ground Resistance Range 0.02ohms to 1600ohms Current Reading Range 1.00mA to 60.0 A TRMS CAT IV 600V 2000 Memory Data Points Low Pass Filter Eliminates Harmonics Over 180hz Hold Function Alarm Function > Each Unit Includes Carrying case Resistance check loop Strap LR06 alkaline batteries Instruction manual

  • Hioki FT6381

    $885

    Bluetooth Real Time Data Transfer to Android Based Phone 1.26 In. Jaw Window Ground Resistance Range 0.02ohms to 1600ohms Current Reading Range 1.00mA to 60.0 A TRMS CAT IV 600V 2000 Memory Data Points Low Pass Filter Eliminates Harmonics Over 180hz Hold Function Alarm Function > Each Unit Includes Carrying case Resistance check loop Strap LR06 alkaline batteries Instruction manual

  • Hioki LR8512

    $229

    For pulse totalization and measuring logical ON/OFF signals or revolutions Compact, two-channel model fits where other devices dont Measurement data is sent to the Hioki LR8410 using Bluetooth® wireless technology Measurement data is saved even when communications are interrupted Three-way power (AC adapter, AA alkaline batteries, or external 5 to 13.5 V power supply) Instrument can store 500,000 data points per channel

  • Hioki RM3542

    $1.748

    High speed and accuracy maximize productivity in automated systems Multiple checking functions ensure proper contact for reliable measurements Low-power resistance mode measures chip inductors and EMC suppression components Supports sample inspections during the manufacturing process Display Monochrome graphic LCD 240 × 64 dot, white LED backlight Measurement accuracy [with SLOW mode, at 100 mO range] ±0.015 % rdg. ±0.002 % f.s. [with SLOW mode, at 1000 O range] ±0.006 % rdg. ±0.001 % f.s. (the best case) Testing current [at 100 mO range] 100 mA DC to [at 100 MO range] 100 nA DC Open-terminal voltage 20 V DC max. Sampling rate FAST, MEDIUM, SLOW, 3 settings Measurement times [at 100 O /1000 O ranges, with Low Power OFF] FAST: 0.9 ms, MED: 3.6 ms, SLOW: 17 ms (minimum time) Integration time 0.1 ms to 100.0 ms, or 1 to 5 PLC at 50 Hz, 1 to 6 PLC at 60 Hz Note: PLC = one power line cycle (mains wave-form period) Other functions Comparator (compare setting value with measurement value), Delay (set to allow for mechanical delay of trigger input and probing, or set to allow for measurement object response), OVC (offset voltage compensation), Measurement fault detection, Probe short-circuit detection, Improve contact, Auto-memory, Statistical calculations, Settings monitor (when using two instruments, a difference in settings causes warning notification), Retry, Trigger function. etc,. Interface RS-232C, Printer, GP-IB (Model RM3542-01) External I/O Trigger, Hold input, Comparator output, Settings monitor terminal Power supply, consumption 100 to 240 V AC, 50/60 Hz, 30 VA max. Dimensions, mass 260 mm (10.24 in) W × 88 mm (3.46 in) H × 300 mm (11.81 in) D, 2.9 kg (102.3 oz) > Each Unit Includes Power cord EXT I/O male connector Operation manual Operation guide

  • Hioki RM3542-01

    $1.928

    High speed and accuracy maximize productivity in automated systems Multiple checking functions ensure proper contact for reliable measurements Low-power resistance mode measures chip inductors and EMC suppression components Supports sample inspections during the manufacturing process Display Monochrome graphic LCD 240 × 64 dot, white LED backlight Measurement accuracy [with SLOW mode, at 100 mO range] ±0.015 % rdg. ±0.002 % f.s. [with SLOW mode, at 1000 O range] ±0.006 % rdg. ±0.001 % f.s. (the best case) Testing current [at 100 mO range] 100 mA DC to [at 100 MO range] 100 nA DC Open-terminal voltage 20 V DC max. Sampling rate FAST, MEDIUM, SLOW, 3 settings Measurement times [at 100 O /1000 O ranges, with Low Power OFF] FAST: 0.9 ms, MED: 3.6 ms, SLOW: 17 ms (minimum time) Integration time 0.1 ms to 100.0 ms, or 1 to 5 PLC at 50 Hz, 1 to 6 PLC at 60 Hz Note: PLC = one power line cycle (mains wave-form period) Other functions Comparator (compare setting value with measurement value), Delay (set to allow for mechanical delay of trigger input and probing, or set to allow for measurement object response), OVC (offset voltage compensation), Measurement fault detection, Probe short-circuit detection, Improve contact, Auto-memory, Statistical calculations, Settings monitor (when using two instruments, a difference in settings causes warning notification), Retry, Trigger function. etc,. Interface RS-232C, Printer, GP-IB (Model RM3542-01) External I/O Trigger, Hold input, Comparator output, Settings monitor terminal Power supply, consumption 100 to 240 V AC, 50/60 Hz, 30 VA max. Dimensions, mass 260 mm (10.24 in) W × 88 mm (3.46 in) H × 300 mm (11.81 in) D, 2.9 kg (102.3 oz) > Each Unit Includes Power cord EXT I/O male connector Operation manual Operation guide

  • Hioki RM3543

    $2.099

    ±0.16% accuracy & 0.01µohm resolution performance in automated systems Superb repeatable measurement accuracy Provide advanced contact-check, comparator, and data export functions It is intuitive user interface and strong noise immunity are suitable for use in automated systems Measurement method Four-terminal, constant-current DC Resistance range 10 mohm (Max. 12.00000 mohm, 0.01 µohm resolution) to 1000 ohm range (Max. 1200.000 ohm, 1 mohm resolution), 7 steps Display Monochrome graphic LCD 240 × 64 dot, white LED backlight Measurement accuracy [at 10 mohm range, with SLOW mode, average 16 times settings] ±0.060 % rdg. ±0.001 % f.s. Testing current [at 10 mohm range] 1 A DC to [at 1000 ohm range] 1 mA DC Open-terminal voltage 20 V DC max. Note: Voltage when not measuring is 20 mV or less, with current mode set at PULSE and Contact Improver Setting set at OFF/PULSE (measured with a voltmeter having 10 Mohm) Sampling rate FAST, MEDIUM, SLOW, 3 settings Integration time [at 10 mohm range, default value] FAST 2.0 ms, MED 5.0 ms, SLOW 1 PLC, Setting range: 0.1 ms to 100.0 ms, or 1 to 5 PLC at 50 Hz, 1 to 6 PLC at 60 Hz Note: PLC = one power line cycle (mains wave-form period) Other functions Comparator (compare setting value with measurement value), Delay, OVC (offset voltage compensation), Average, Measurement fault detection, Probe short-circuit detection, Improve contact, Current mode setting (A pulse application function that applies current only during measurement), Auto-memory, Statistical calculations, Settings monitor (when using two instruments, a difference in settings causes warning notification), Retry, Trigger function. etc,. Interface External I/O, RS-232C, Printer, GP-IB (Model RM3543-01) External I/O Trigger, Hold input, Comparator output, Settings monitor terminal, Service power output 5V, 12V, etc. Power supply, consumption 100 to 240 V AC, 50/60 Hz, 40 VA max. Dimensions, mass 260 mm (10.24 in) W × 88 mm (3.46 in) H × 300 mm (11.81 in) D, 3.0 kg (105.8 oz) > Each Unit Includes Power cord EXT I/O male connector Operation manual Operation guide

  • Hioki RM3543-01

    $2.265

    ±0.16% accuracy & 0.01µohm resolution performance in automated systems Superb repeatable measurement accuracy Provide advanced contact-check, comparator, and data export functions It is intuitive user interface and strong noise immunity are suitable for use in automated systems Measurement method Four-terminal, constant-current DC Resistance range 10 mohm (Max. 12.00000 mohm, 0.01 µohm resolution) to 1000 ohm range (Max. 1200.000 ohm, 1 mohm resolution), 7 steps Display Monochrome graphic LCD 240 × 64 dot, white LED backlight Measurement accuracy [at 10 mohm range, with SLOW mode, average 16 times settings] ±0.060 % rdg. ±0.001 % f.s. Testing current [at 10 mohm range] 1 A DC to [at 1000 ohm range] 1 mA DC Open-terminal voltage 20 V DC max. Note: Voltage when not measuring is 20 mV or less, with current mode set at PULSE and Contact Improver Setting set at OFF/PULSE (measured with a voltmeter having 10 Mohm) Sampling rate FAST, MEDIUM, SLOW, 3 settings Integration time [at 10 mohm range, default value] FAST 2.0 ms, MED 5.0 ms, SLOW 1 PLC, Setting range: 0.1 ms to 100.0 ms, or 1 to 5 PLC at 50 Hz, 1 to 6 PLC at 60 Hz Note: PLC = one power line cycle (mains wave-form period) Other functions Comparator (compare setting value with measurement value), Delay, OVC (offset voltage compensation), Average, Measurement fault detection, Probe short-circuit detection, Improve contact, Current mode setting (A pulse application function that applies current only during measurement), Auto-memory, Statistical calculations, Settings monitor (when using two instruments, a difference in settings causes warning notification), Retry, Trigger function. etc,. Interface External I/O, RS-232C, Printer, GP-IB (Model RM3543-01) External I/O Trigger, Hold input, Comparator output, Settings monitor terminal, Service power output 5V, 12V, etc. Power supply, consumption 100 to 240 V AC, 50/60 Hz, 40 VA max. Dimensions, mass 260 mm (10.24 in) W × 88 mm (3.46 in) H × 300 mm (11.81 in) D, 3.0 kg (105.8 oz) > Each Unit Includes Power cord EXT I/O male connector Operation manual Operation guide