Showing 514–522 of 538 results

  • Newport Electronics FMA1828A

    $475

    The FMA1800A Series eletronic gas mass flowmeters provide for monitoring the flow of a wide variety of gases from 10 SCCM up to 1000 SLM. Utilizing heat transfer through a heated tube to measure molecular gas flow rate, the FMA1700A/1800A provides measurement of direct gas mass flow rate, without the need to compensate for variations in gas temperature or pressure (within stated limits). 0 to 50 SLM range Reads Gas Mass Flow Without Temperature or Pressure Compensation Available in Economical Aluminum or Corrosion- Resistant 316 SS Tiltable LCD Display for Easy Reading NIST Traceable Calibration Included Accuracy: ±1% of full scale, including linearity over 15 to 25°C and 5 to 60 psia (0.35 to 4.2 kg/cm²)(For sizes up to 100SLM), ±1.5% of full scale, including linearity over 15 to 25°C and 5 to 60 psia (0.35 to 4.2 kg/cm²)For larger sizes) Turn-Down Ratio: 100:1 Repeatability: ±0.5% of full scale and for units ≥100 scm from 0 to 20% of range Temperature Coefficient: 0.15% of full scale per °C or better Pressure Coefficient: 0.01% of full scale per psi (0.07 bar) Response Time: 800 msec time constant, 2 seconds (typical) to within ±2% of set flow rate over 25 to 100% of full scale Power Requirements:12 to 26 Vdc power @200 mA maximum Maximum Gas Pressure: 1000 psig (70 kg/cm² gauge) for ranges upto 100 SLM, 500 psig (35 kg/cm² gauge)Above 100 SLM, 20 psig optimum Gas and Ambient Temperature: 0 to 50°C (0 to 122°F) Leak Integrity: 1 x 10-9, std cc/sec of helium maximum to outside environment Materials in Fluid Contact: Aluminum models: Anodized aluminum, 316 SS, brass and FKM O-rings Stainless Steel models: 316 SS and FKM O-rings Output Signal Linear 0 to 5 Vdc: 1000 Ω minimum load 4 to 20 mA: 50 to 250 Ω loop resistance Transducer Power: 12 Vdc @ 200 mA maximum (FMA178PW) Shipping Weight: 1.1 kg (2.5 lb) Compliance: EN55011 class 1, class B, EN50082-1

  • Newport Electronics FMA6704

    $898

    Max Flow 100 cc/min 1/4 Compression Fitting Multi-Drop Capability of Up to 256 Units (for RS-485 Option) Stores Calibration Data for Up to 10 Different Gases Supports 10 Different Engineering Units Including User Defined Programmable 12 Digits Totalizer Indicates Total Gas Volume Flow Alarm Limits for High and Low Gas Flow with Relay Output Pressure Alarm (FMA6700) Limits for High and Low Gas Pressure with Relay Output Temperature Alarm (FMA6700) Limits for High and Low Gas Temperature with Relay Output Digital (RS-232 or RS-485) and Analog Outputs Operate Simultaneously Internal Conversion Factors for Up to 32 Gases Accuracy: FMA6700: ±1% of FS including linearity [0 to 50°C and 0.35 to 6.8 bar (5 to 100 psia)] Pressure Range: 0 to 6.8 bar (100 psig) (measurement) Pressure Accuracy: ±1% of FS Temperature Range: 0 to 50°C (measurement) Temperature Accuracy: ±1°C Repeatability: ±0.15% of full scale Response Time: Units up to 10 LPM @1.0 second, units greater than 10 LPM @2 seconds to within ±2% of setpoint over 25% to 100% of full scale Temp. Coefficient: 0.15% of full scale/°C or better Pressure Coefficient: 0.01% of full scale/psi (0.07 bar) or better Max Gas Pressure: 6.8 bar (100 psig) Max Burst Pressure: 13.6 bar (200 psig) Max Pressure Drop: 8 psi (at 100 L/min flow) Gas & Ambient Temp: 5 to 50°C (41 to 122°F) Output Signals: Linear 0 to 5 Vdc (3000 Ω min load impedance), 0 to 10 Vdc (6000 Ω min impedance), 4 to 20 mA optional (500 . max loop resistance). Maximum noise 20 mV peak to peak. Input Power: Is available to run at three different voltages: ±15Vdc (±200 mA maximum) or 12Vdc (300 mA maximum) standard, 24Vdc (250 mA maximum) optional (-24VDC), Circuit boards have built-in polarity reversal protection. Resettable fuses provide power input protection. Materials in Fluid Contact: 316 stainless steel, FKM O-rings. EPDM or Perfluoroelastomer O-rings optional Connections: Models 60 to 100 LPM: Standard 3/8 compression fittings Display: 128 x 64 graphic LCD with backlight (up to 8 lines of text) Calibration: Standard one 10 points NIST calibration. Optional up to 9 additional calibrations may be ordered for an additional charge per gas. CE Compliance: EN 55011 class 1, class B, EN50082-1 Environmental (per IEC 664): Installation Level II, Pollution Degree II Approximate Shipping Weights: 1.97 kg (4.34 lb)

  • Newport Electronics FMA6718

    $1.022

    Pressure/Temperature Gas Flowmeter,0-100LPM Multi-Drop Capability of Up to 256 Units (for RS-485 Option) Stores Calibration Data for Up to 10 Different Gases Supports 10 Different Engineering Units Including User Defined Programmable 12 Digits Totalizer Indicates Total Gas Volume Flow Alarm Limits for High and Low Gas Flow with Relay Output Pressure Alarm (FMA6700) Limits for High and Low Gas Pressure with Relay Output Temperature Alarm (FMA6700) Limits for High and Low Gas Temperature with Relay Output Digital (RS-232 or RS-485) and Analog Outputs Operate Simultaneously Internal Conversion Factors for Up to 32 Gases Accuracy: FMA6700: ±1% of FS including linearity [0 to 50°C and 0.35 to 6.8 bar (5 to 100 psia)] Pressure Range: 0 to 6.8 bar (100 psig) (measurement) Pressure Accuracy: ±1% of FS Temperature Range: 0 to 50°C (measurement) Temperature Accuracy: ±1°C Repeatability: ±0.15% of full scale Response Time: Units up to 10 LPM @1.0 second, units greater than 10 LPM @2 seconds to within ±2% of setpoint over 25% to 100% of full scale Temp. Coefficient: 0.15% of full scale/°C or better Pressure Coefficient: 0.01% of full scale/psi (0.07 bar) or better Max Gas Pressure: 6.8 bar (100 psig) Max Burst Pressure: 13.6 bar (200 psig) Max Pressure Drop: 8 psi (at 100 L/min flow) Gas & Ambient Temp: 5 to 50°C (41 to 122°F) Output Signals: Linear 0 to 5 Vdc (3000 Ω min load impedance), 0 to 10 Vdc (6000 Ω min impedance), 4 to 20 mA optional (500 . max loop resistance). Maximum noise 20 mV peak to peak. Input Power: Is available to run at three different voltages: ±15Vdc (±200 mA maximum) or 12Vdc (300 mA maximum) standard, 24Vdc (250 mA maximum) optional (-24VDC), Circuit boards have built-in polarity reversal protection. Resettable fuses provide power input protection. Materials in Fluid Contact: 316 stainless steel, FKM O-rings. EPDM or Perfluoroelastomer O-rings optional Connections: Models 60 to 100 LPM: Standard 3/8 compression fittings Display: 128 x 64 graphic LCD with backlight (up to 8 lines of text) Calibration: Standard one 10 points NIST calibration. Optional up to 9 additional calibrations may be ordered for an additional charge per gas. CE Compliance: EN 55011 class 1, class B, EN50082-1 Environmental (per IEC 664): Installation Level II, Pollution Degree II Approximate Shipping Weights: 1.97 kg (4.34 lb)

  • Onset HOBO Data Loggers T-CDI-5200-10S

    $274

    The T-CDI-5200-10S is a flowmeter for compressed air systems. It measures flow by maintaining one probe warmer than the other. It calculates the mass velocity from the amount of heat required, and then calculates the flow on the basis of pipe area. This model fits 1 steel pipes.

  • Onset HOBO Data Loggers T-CDI-5400-20S

    $347

    Effectively monitor compressed air systems with the T-CDI-5400-20S. This flowmeter includes two probes, one warmer than the other. This arrangement calculates mass velocity based on heat requirements. Additionally, pipe area data is used to determine flow amounts. This product fits a two-inch steel pipe.

  • Panametrics DF868

    $4.001

    Fixed Installation Flowmeter,2- Channel,100-120VAC Order #: DF868-2-11-101000-0 Mfg #: DF868-2-11-101000-0

  • Panametrics DF868

    $4.104

    Fixed Installation Digital Flow Meter Order #: DF868-1-12-101000-0 Mfg #: DF868-1-12-101000-0

  • Panametrics DF868

    $3.386

    Fixed Installation Digital Flow Meter Order #: DF868-1-1-1-13000 Mfg #: DF868-1-1-1-13000

  • Panametrics DF868

    $3.181

    Fixed Installation Digital Flow Meter Order #: DF868-1-11-10000 Mfg #: DF868-1-11-10000