Showing 118–126 of 538 results
-
$415
Low Cost, Series HF In-Line Flow Monitors have a design based on a floating sharp-edged orifice disk and variable area flow measurement to yield accuracy of ±2.5% over center one-third of scale. This unique design allows accurate performance with fluid viscosities up to 500 SSU. All internal wetted parts are contained inside a sealed metal tubular casing assuring a virtually maintenance-free unit. Flowing media forces linear motion of a spring loaded, sharp edge orifice disk and ring shaped transfer magnet which both ride on a tapered center shaft. The transfer magnet drives a clearly visible magnet follower located outside the flow tube, protected under the clear polycarbonate tube. A ring on the magnet follower indicates flow rate on the direct reading scale. Rubber bumpers are provided for external impact resistance. Designed for single-direction flow, Series HF Monitors are recommended for use with system filtration of at least 74 microns or a 200 mesh screen. Some applications may also require magnetic filtration. These flowmeters do not require inlet or outlet straight plumbing and can be mounted horizontally, vertically, or inverted. 1/2 female NPT, 0.2-2 GPM (.75-7.5 LPM) water
-
$415
Low Cost, Series HF In-Line Flow Monitors have a design based on a floating sharp-edged orifice disk and variable area flow measurement to yield accuracy of ±2.5% over center one-third of scale. This unique design allows accurate performance with fluid viscosities up to 500 SSU. All internal wetted parts are contained inside a sealed metal tubular casing assuring a virtually maintenance-free unit. Flowing media forces linear motion of a spring loaded, sharp edge orifice disk and ring shaped transfer magnet which both ride on a tapered center shaft. The transfer magnet drives a clearly visible magnet follower located outside the flow tube, protected under the clear polycarbonate tube. A ring on the magnet follower indicates flow rate on the direct reading scale. Rubber bumpers are provided for external impact resistance. Designed for single-direction flow, Series HF Monitors are recommended for use with system filtration of at least 74 microns or a 200 mesh screen. Some applications may also require magnetic filtration. These flowmeters do not require inlet or outlet straight plumbing and can be mounted horizontally, vertically, or inverted. 1/2 female NPT, 0.5-10 GPM (1.9-38 LPM) water
-
$569
The Series HFT combines a direct reading HF flowmeter with electronics to provide a proportional analog output of 4-20 mA, 0-5 and 1-5 VDC. Use the output to drive data acquisition devices, meters or analog input cards. The entire assembly is housed in a rugged cast aluminum NEMA 4X enclosure. The unit can be installed in outdoor applications or harsh environments where liquid tight seals are required. The flow transmitter does not require input or output straight plumbing, and can be mounted in any orientation. Range 1.5-12 SCFM air, 1/4 female NPT
-
$569
The Series HFT combines a direct reading HF flowmeter with electronics to provide a proportional analog output of 4-20 mA, 0-5 and 1-5 VDC. Use the output to drive data acquisition devices, meters or analog input cards. The entire assembly is housed in a rugged cast aluminum NEMA 4X enclosure. The unit can be installed in outdoor applications or harsh environments where liquid tight seals are required. The flow transmitter does not require input or output straight plumbing, and can be mounted in any orientation. Range 4-23 SCFM air, 1/4 female NPT
-
$603
The Series HFT combines a direct reading HF flowmeter with electronics to provide a proportional analog output of 4-20 mA, 0-5 and 1-5 VDC. Use the output to drive data acquisition devices, meters or analog input cards. The entire assembly is housed in a rugged cast aluminum NEMA 4X enclosure. The unit can be installed in outdoor applications or harsh environments where liquid tight seals are required. The flow transmitter does not require input or output straight plumbing, and can be mounted in any orientation. Range 0.5-5.0 GPM (1-19 LPM) water, 1/2 female NPT
-
$655
The Series HFT combines a direct reading HF flowmeter with electronics to provide a proportional analog output of 4-20 mA, 0-5 and 1-5 VDC. Use the output to drive data acquisition devices, meters or analog input cards. The entire assembly is housed in a rugged cast aluminum NEMA 4X enclosure. The unit can be installed in outdoor applications or harsh environments where liquid tight seals are required. The flow transmitter does not require input or output straight plumbing, and can be mounted in any orientation. Range 1-15 GPM (3.8-55 LPM) water, 3/4 female NPT
-
$655
The Series HFT combines a direct reading HF flowmeter with electronics to provide a proportional analog output of 4-20 mA, 0-5 and 1-5 VDC. Use the output to drive data acquisition devices, meters or analog input cards. The entire assembly is housed in a rugged cast aluminum NEMA 4X enclosure. The unit can be installed in outdoor applications or harsh environments where liquid tight seals are required. The flow transmitter does not require input or output straight plumbing, and can be mounted in any orientation. Range 2-20 GPM (7.5-75 LPM) water, 3/4 female NPT
-
$655
The Series HFT combines a direct reading HF flowmeter with electronics to provide a proportional analog output of 4-20 mA, 0-5 and 1-5 VDC. Use the output to drive data acquisition devices, meters or analog input cards. The entire assembly is housed in a rugged cast aluminum NEMA 4X enclosure. The unit can be installed in outdoor applications or harsh environments where liquid tight seals are required. The flow transmitter does not require input or output straight plumbing, and can be mounted in any orientation. Range 4-40 GPM (15-151 LPM) water, 1 female NPT
-
$1.270
The Series HFT combines a direct reading HF flowmeter with electronics to provide a proportional analog output of 4-20 mA, 0-5 and 1-5 VDC. Use the output to drive data acquisition devices, meters or analog input cards. The entire assembly is housed in a rugged cast aluminum NEMA 4X enclosure. The unit can be installed in outdoor applications or harsh environments where liquid tight seals are required. The flow transmitter does not require input or output straight plumbing, and can be mounted in any orientation. Range 5-50 GPM (19-189 LPM) water, 1-1/2 female NPT