Showing 1459–1467 of 1467 results

  • TSI Incorporated RVA501

    $418

    Measures velocity and temperature Sweep mode for one overall measurement of large areas Log, store, and recall data Download data to a PC using LogDat2 downloading software Measurement range: 50–6000 ft/min (0.25–30 m/s) Optional telescopic probe available Compatible with Aircone Flow Hoods > Each Unit Includes Instrument Carrying case Alkaline batteries USB cable and downloading software Operation and service manual NIST calibration certificate

  • Vaisala DM70

    $1.581

    Designed for industrial spot-checking applications and field calibration Provides convenient measurement in dry conditions Wide dewpoint measurement range: from -60 to 60 °C Truly fast response Superior long-term stability Compact, small and light Easy-to-use user interface Withstands condensation Data-logging and transferring capabilities Incorporates the DRYCAP® Sensor Auto-calibration procedure works on-line and makes a correction for any dry-end drift to the calibration curve, giving DM70 a superior performance with minimum maintenance NIST traceable certifiate included Weight: 400g

  • Vaisala GM70

    $1.692

    Proven Vaisala CARBOCAP® reliability Two optional sampling methods: diffusion or pump aspiration User-friendly meter with multilingual user interface Numerical and graphical display of measurements Data can be logged and transferred to PC via MI70 Link software Wide selection of measurement ranges Easy recalibration using the interchangeable probes Suitable for field checking of fixed CO2 instruments Short warm-up time Compact and versatile

  • Vaisala HM70

    $1.154

    Multilingual user interface Shows measurement trends graphically Proven Vaisala HUMICAP® Sensor technology 3 probe alternatives, temperature measurement ranges between -70 and 180 °C Multiprobe operation, dew point and CO2 probes can also be connected 2 probes can be connected simultaneously Displays various humidity parameters Sensor preheat and chemical purge options for demanding conditions NIST traceable (certificate included) > Each Unit Includes Weatherproof plastic carry case for MI70 and HMP76/76B (MI70CASE4) NIST Traceable Certificate

  • Vaisala HM70

    $1.325

    RH measurement range 0…100 % RH Multilingual user interface Shows measurement trends graphically Proven Vaisala HUMICAP® Sensor technology 3 probes, temperature measurement ranges between -70 and 180 °C Multiprobe operation, dewpoint and CO2 probes can also be connected Displays various humidity parameters Sensor preheat and chemical purge options for demanding conditions Data can be logged, and transferred to a PC via MI70 Link software Rugged and reliable even in extreme conditions NIST traceable (certificate included)

  • Vaisala PTB110

    $646

    Pressure range of 500-1100 hPa Temperature range of -40°C to 60 °C (-40°F to 140 °F) Accuracy of ±0.3 hPa at 20 °C Long-term stability On/off control with external trigger Output voltage of 0-5 VDC Current consumption less than 4 mA Mountable on a (35 mm wide) DIN rail > Each Unit Includes NIST traceable certificate

  • YSI 626900

    $581

    Digital smart sensor stores calibration data — change sensors without recalibrating The ProDSS sensor housing accepts four user-replaceable sensors at a time and the universal connector system allows any sensor to connect with any housing port. Meter Type Accessory, Probes and Sensors Min Dissolved Oxygen 0 to 500%, 0 to 50 ppm Dissolved Oxygen Resolution 0.1 or 0.01 ppm, 0.1 or 1% saturation Dissolved Oxygen Accuracy±1% of rdg or 1% saturation, whichever is greater (up to 200%), ±8% of rdg (above 200%), ±0.1 ppm or 1% of rdg, whichever is greater (up to 20 ppm), ±8% of rdg (above 20 ppm) Data Logging (points) Calibration data

  • YSI 626901

    $615

    Digital smart sensor stores calibration data — change sensors without recalibrating Meter Type Accessory, Probes and Sensors Min Turbidity0 to 400 0 FNU Turbidity Resolution 0.1 FNU Turbidity Accuracy ±0.3 FNU or ±2% of rdg, whichever is greater (up to 999 FNU), ±5% of rdg (above 999 FNU) Data Logging (points) Calibration data

  • YSI 626902

    $415

    Digital smart sensor stores calibration data — change sensors without recalibrating Meter Type Accessory, Probes and Sensors Min Conductivity 0 to 200 mS Conductivity Accuracy ±0.5% of reading or 0.001 mS/cm, whichever is greater (up to 100 mS/cm), ±1.0% of reading from 100 to 200 mS/cm Min TDS 0 to 100 ppt Data Logging (points) Calibration data Conductivity cell (59354-11) has four electrodes and houses the Automatic Temperature Compensation (ATC) thermistor.