Showing 1315–1323 of 1343 results

  • UEi DM5B

    $21

    Auto range feature Measures 750 V AC/DC with 1000V protection Measures AC and DC current to 5 amps Tests continuity prvodes a quick audible tone Measures resistance to 30 Megohms Fuse Protected current ranges Three year limited warranty

  • UEi DMEG3

    $152

    Large digital display shows the test function and measured value 600V AC measurement capability Insulation resistance ranges 0 2000 MΩ Three test-voltage ranges (250, 500, 1000 V DC) Live circuit warning light Fuse protected Precision resistance 0.01Ω with audible continuity 200 mA short-circuit continuity test current for high accuracy Precision, low resistance test leads (1000 Volts CAT III rated) Audible continuity Green LED power-on indicator Low battery indication / detection Maintains rated voltage on cables with up to 1 mA leak-rate Automatic, post-test cable discharge Rugged, compact case with protective cover Three year limited warranty > Each Unit Includes Test Leads 8 Batteries 1.5V, “AA” Alkaline (R6) Fuse 0.5A 250V Instruction Manual Alligator Clips Hard Carrying Case

  • UEi IRT20

    $257

    UEI Model # IRT20 Water resistant, ruged metal casing No power source needed Damping time better than 4 seconds Operate anywhere, under any conditions Accuracy at 77° F ± 1% of full scale 1 year limited warranty

  • Vitrek 951I

    $2.492

    Product Highlihgts Highest Level of Operator Safety – features include: GFI High speed shut down for earth ground leakage faults, SFI™ Safety Fault Interlock – High speed shut down output for interruption of safety interlock, TLSS™ Test Lead Safety Sense – Clamps DUT chassis near ground by continuously verifying proper connection of test leads prior to and during HV testing, Recessed start switch prevents inadvertent actuation High Power Output – means better drive capability and increased test throughout. With up to 50mA of sourcing current for DC hipot the 95X Series gets heavy duty jobs done fast – available 100mA & 200mA AC drive tackles even the toughest sourcing requirements Wide Range of built-in Voltage Capabilities – Choose from 6.5KVDC, 11KVDC or 15KVDC and 6KVAC, 10KVAC or up to 30KV RMS AC with external option The Fastest Hipot Testers available – Thanks to our Dual Coldfire® microprocessors combined with Dual DSPs to provide Ramp rates up to 50KV/second, dwell times as low as 20mS and overall test times as fast as 3mS in optional Flash mode Expansive Test Sequence Memory holds up to 100 tests with up to 100 steps per test. Tests can be selected via front panel, Ethernet, RS232, Digital I/O or with optional GPIB Ground Bond Test Capability available in three models with output currents from 100mA to 40Amps RMS and test times from 20mS to 1000 seconds or longer 4-Wire Milli-Ohmmeter Function provides fast, accurate 5 digit resistance measurements with resolution down to 100µΩ and range up to 100K ohms Built-in Phase Angle Measurement – allows the measurement and display of both resistive (in-phase) leakage current and reactive (out-of-phase) leakage current caused by capacitive coupling Multi-Dwell Functionality – permits dwells at different voltage levels without having to return to zero between test steps – dramatically simplifying advanced analysis of dielectric properties Ramp High/Dwell Low Current Limits – permits the user to set separate limits for the ramp and dwell providing faster ramp times and lower leakage test limits Ethernet, RS232, Digital I/O, USB Printer & Scanner Control – All Standard Interfaces – Provides the highest level of test automation. GPIB optional High Voltage Scanner Control – up to 256 point switching capability with available 964i HV Scanners. Route voltages up to 15KV and currents up to 40A for multi-point hipot and ground bond tests Dual Dimensional / Test Specific / Broadband Arc Detection. Where lesser testers allow you to set a single, global, amplitude only arc limit – the technologically advanced 95X Series utilizes time & amplitude based arc limits and uniquely applies them to each desired test Pico-Amp Leakage Measurement insures that even the lowest leakage current levels are accurately detected and tera-ohm range IR readings are stable and precise Test Specific Fixture & Cable Compensation – Automatically calibrate out offset errors caused by lead resistance, fixture capacitance and leakage Multi-Mode IR – Insulation Resistance values up to one Tera-ohm can be obtained with precision in your choice of 3 IR test modes – end on time, end on pass or end on fail Continuously Variable IR Test Voltage – Unlike most IR testers which limit you to 3 or 4 discrete test voltages, the 950i Series allows you to select the test voltage you need. Starting as low as 20V all the way to 6.5KV, 11KV or 15KVDC Capacitance Test Modes – For AC & DC hipot and IR provide tightly controlled charge and discharge profiles for superior results on critical solar panel tests and other highly capacitive loads Light Weight Switching Power Supply Design – Better reliability, easier on your back. Compare the 8.2 kg 95X to whatever youve been using 400Hz AC Voltage Withstand Testing provides aviation frequency specific test results for a more effective analysis of dielectric properties on avionic components Solar Panel Testing Simplified – Designed with PV testing in mind, the 950i Series uses pico-amp resolution to detect minute defects in solar cells 3 Year Extended Warranty – 1 year standard, total of 3 years extended warranty with registration and annual factory calibration. Built-in reliability you can count on for years to come Safety Tested per EN 61010-1. EMC compliant to EN 61326-1 > Each Unit Includes Alligator test leads NIST traceable calibration certificate with no data power cord and operators manual

  • Vitrek 952I

    $2.847

    Product Highlihgts Highest Level of Operator Safety – features include: GFI High speed shut down for earth ground leakage faults, SFI™ Safety Fault Interlock – High speed shut down output for interruption of safety interlock, TLSS™ Test Lead Safety Sense – Clamps DUT chassis near ground by continuously verifying proper connection of test leads prior to and during HV testing, Recessed start switch prevents inadvertent actuation High Power Output – means better drive capability and increased test throughout. With up to 50mA of sourcing current for DC hipot the 95X Series gets heavy duty jobs done fast – available 100mA & 200mA AC drive tackles even the toughest sourcing requirements Wide Range of built-in Voltage Capabilities – Choose from 6.5KVDC, 11KVDC or 15KVDC and 6KVAC, 10KVAC or up to 30KV RMS AC with external option The Fastest Hipot Testers available – Thanks to our Dual Coldfire® microprocessors combined with Dual DSPs to provide Ramp rates up to 50KV/second, dwell times as low as 20mS and overall test times as fast as 3mS in optional Flash mode Expansive Test Sequence Memory holds up to 100 tests with up to 100 steps per test. Tests can be selected via front panel, Ethernet, RS232, Digital I/O or with optional GPIB Ground Bond Test Capability available in three models with output currents from 100mA to 40Amps RMS and test times from 20mS to 1000 seconds or longer 4-Wire Milli-Ohmmeter Function provides fast, accurate 5 digit resistance measurements with resolution down to 100µΩ and range up to 100K ohms Built-in Phase Angle Measurement – allows the measurement and display of both resistive (in-phase) leakage current and reactive (out-of-phase) leakage current caused by capacitive coupling Multi-Dwell Functionality – permits dwells at different voltage levels without having to return to zero between test steps – dramatically simplifying advanced analysis of dielectric properties Ramp High/Dwell Low Current Limits – permits the user to set separate limits for the ramp and dwell providing faster ramp times and lower leakage test limits Ethernet, RS232, Digital I/O, USB Printer & Scanner Control – All Standard Interfaces – Provides the highest level of test automation. GPIB optional High Voltage Scanner Control – up to 256 point switching capability with available 964i HV Scanners. Route voltages up to 15KV and currents up to 40A for multi-point hipot and ground bond tests Dual Dimensional / Test Specific / Broadband Arc Detection. Where lesser testers allow you to set a single, global, amplitude only arc limit – the technologically advanced 95X Series utilizes time & amplitude based arc limits and uniquely applies them to each desired test Pico-Amp Leakage Measurement insures that even the lowest leakage current levels are accurately detected and tera-ohm range IR readings are stable and precise Test Specific Fixture & Cable Compensation – Automatically calibrate out offset errors caused by lead resistance, fixture capacitance and leakage Multi-Mode IR – Insulation Resistance values up to one Tera-ohm can be obtained with precision in your choice of 3 IR test modes – end on time, end on pass or end on fail Continuously Variable IR Test Voltage – Unlike most IR testers which limit you to 3 or 4 discrete test voltages, the 950i Series allows you to select the test voltage you need. Starting as low as 20V all the way to 6.5KV, 11KV or 15KVDC Capacitance Test Modes – For AC & DC hipot and IR provide tightly controlled charge and discharge profiles for superior results on critical solar panel tests and other highly capacitive loads Light Weight Switching Power Supply Design – Better reliability, easier on your back. Compare the 8.2 kg 95X to whatever youve been using 400Hz AC Voltage Withstand Testing provides aviation frequency specific test results for a more effective analysis of dielectric properties on avionic components Solar Panel Testing Simplified – Designed with PV testing in mind, the 950i Series uses pico-amp resolution to detect minute defects in solar cells 3 Year Extended Warranty – 1 year standard, total of 3 years extended warranty with registration and annual factory calibration. Built-in reliability you can count on for years to come Safety Tested per EN 61010-1. EMC compliant to EN 61326-1 > Each Unit Includes Alligator test leads NIST traceable calibration certificate with no data power cord and operators manual

  • Vitrek 953I

    $2.958

    Product Highlihgts Highest Level of Operator Safety – features include: GFI High speed shut down for earth ground leakage faults, SFI™ Safety Fault Interlock – High speed shut down output for interruption of safety interlock, TLSS™ Test Lead Safety Sense – Clamps DUT chassis near ground by continuously verifying proper connection of test leads prior to and during HV testing, Recessed start switch prevents inadvertent actuation High Power Output – means better drive capability and increased test throughout. With up to 50mA of sourcing current for DC hipot the 95X Series gets heavy duty jobs done fast – available 100mA & 200mA AC drive tackles even the toughest sourcing requirements Wide Range of built-in Voltage Capabilities – Choose from 6.5KVDC, 11KVDC or 15KVDC and 6KVAC, 10KVAC or up to 30KV RMS AC with external option The Fastest Hipot Testers available – Thanks to our Dual Coldfire® microprocessors combined with Dual DSPs to provide Ramp rates up to 50KV/second, dwell times as low as 20mS and overall test times as fast as 3mS in optional Flash mode Expansive Test Sequence Memory holds up to 100 tests with up to 100 steps per test. Tests can be selected via front panel, Ethernet, RS232, Digital I/O or with optional GPIB Ground Bond Test Capability available in three models with output currents from 100mA to 40Amps RMS and test times from 20mS to 1000 seconds or longer 4-Wire Milli-Ohmmeter Function provides fast, accurate 5 digit resistance measurements with resolution down to 100µΩ and range up to 100K ohms Built-in Phase Angle Measurement – allows the measurement and display of both resistive (in-phase) leakage current and reactive (out-of-phase) leakage current caused by capacitive coupling Multi-Dwell Functionality – permits dwells at different voltage levels without having to return to zero between test steps – dramatically simplifying advanced analysis of dielectric properties Ramp High/Dwell Low Current Limits – permits the user to set separate limits for the ramp and dwell providing faster ramp times and lower leakage test limits Ethernet, RS232, Digital I/O, USB Printer & Scanner Control – All Standard Interfaces – Provides the highest level of test automation. GPIB optional High Voltage Scanner Control – up to 256 point switching capability with available 964i HV Scanners. Route voltages up to 15KV and currents up to 40A for multi-point hipot and ground bond tests Dual Dimensional / Test Specific / Broadband Arc Detection. Where lesser testers allow you to set a single, global, amplitude only arc limit – the technologically advanced 95X Series utilizes time & amplitude based arc limits and uniquely applies them to each desired test Pico-Amp Leakage Measurement insures that even the lowest leakage current levels are accurately detected and tera-ohm range IR readings are stable and precise Test Specific Fixture & Cable Compensation – Automatically calibrate out offset errors caused by lead resistance, fixture capacitance and leakage Multi-Mode IR – Insulation Resistance values up to one Tera-ohm can be obtained with precision in your choice of 3 IR test modes – end on time, end on pass or end on fail Continuously Variable IR Test Voltage – Unlike most IR testers which limit you to 3 or 4 discrete test voltages, the 950i Series allows you to select the test voltage you need. Starting as low as 20V all the way to 6.5KV, 11KV or 15KVDC Capacitance Test Modes – For AC & DC hipot and IR provide tightly controlled charge and discharge profiles for superior results on critical solar panel tests and other highly capacitive loads Light Weight Switching Power Supply Design – Better reliability, easier on your back. Compare the 8.2 kg 95X to whatever youve been using 400Hz AC Voltage Withstand Testing provides aviation frequency specific test results for a more effective analysis of dielectric properties on avionic components Solar Panel Testing Simplified – Designed with PV testing in mind, the 950i Series uses pico-amp resolution to detect minute defects in solar cells 3 Year Extended Warranty – 1 year standard, total of 3 years extended warranty with registration and annual factory calibration. Built-in reliability you can count on for years to come Safety Tested per EN 61010-1. EMC compliant to EN 61326-1 > Each Unit Includes Alligator test leads NIST traceable calibration certificate with no data power cord and operators manual

  • Vitrek 954I

    $3.394

    Product Highlihgts Highest Level of Operator Safety – features include: GFI High speed shut down for earth ground leakage faults, SFI™ Safety Fault Interlock – High speed shut down output for interruption of safety interlock, TLSS™ Test Lead Safety Sense – Clamps DUT chassis near ground by continuously verifying proper connection of test leads prior to and during HV testing, Recessed start switch prevents inadvertent actuation High Power Output – means better drive capability and increased test throughout. With up to 50mA of sourcing current for DC hipot the 95X Series gets heavy duty jobs done fast – available 100mA & 200mA AC drive tackles even the toughest sourcing requirements Wide Range of built-in Voltage Capabilities – Choose from 6.5KVDC, 11KVDC or 15KVDC and 6KVAC, 10KVAC or up to 30KV RMS AC with external option The Fastest Hipot Testers available – Thanks to our Dual Coldfire® microprocessors combined with Dual DSPs to provide Ramp rates up to 50KV/second, dwell times as low as 20mS and overall test times as fast as 3mS in optional Flash mode Expansive Test Sequence Memory holds up to 100 tests with up to 100 steps per test. Tests can be selected via front panel, Ethernet, RS232, Digital I/O or with optional GPIB Ground Bond Test Capability available in three models with output currents from 100mA to 40Amps RMS and test times from 20mS to 1000 seconds or longer 4-Wire Milli-Ohmmeter Function provides fast, accurate 5 digit resistance measurements with resolution down to 100µΩ and range up to 100K ohms Built-in Phase Angle Measurement – allows the measurement and display of both resistive (in-phase) leakage current and reactive (out-of-phase) leakage current caused by capacitive coupling Multi-Dwell Functionality – permits dwells at different voltage levels without having to return to zero between test steps – dramatically simplifying advanced analysis of dielectric properties Ramp High/Dwell Low Current Limits – permits the user to set separate limits for the ramp and dwell providing faster ramp times and lower leakage test limits Ethernet, RS232, Digital I/O, USB Printer & Scanner Control – All Standard Interfaces – Provides the highest level of test automation. GPIB optional High Voltage Scanner Control – up to 256 point switching capability with available 964i HV Scanners. Route voltages up to 15KV and currents up to 40A for multi-point hipot and ground bond tests Dual Dimensional / Test Specific / Broadband Arc Detection. Where lesser testers allow you to set a single, global, amplitude only arc limit – the technologically advanced 95X Series utilizes time & amplitude based arc limits and uniquely applies them to each desired test Pico-Amp Leakage Measurement insures that even the lowest leakage current levels are accurately detected and tera-ohm range IR readings are stable and precise Test Specific Fixture & Cable Compensation – Automatically calibrate out offset errors caused by lead resistance, fixture capacitance and leakage Multi-Mode IR – Insulation Resistance values up to one Tera-ohm can be obtained with precision in your choice of 3 IR test modes – end on time, end on pass or end on fail Continuously Variable IR Test Voltage – Unlike most IR testers which limit you to 3 or 4 discrete test voltages, the 950i Series allows you to select the test voltage you need. Starting as low as 20V all the way to 6.5KV, 11KV or 15KVDC Capacitance Test Modes – For AC & DC hipot and IR provide tightly controlled charge and discharge profiles for superior results on critical solar panel tests and other highly capacitive loads Light Weight Switching Power Supply Design – Better reliability, easier on your back. Compare the 8.2 kg 95X to whatever youve been using 400Hz AC Voltage Withstand Testing provides aviation frequency specific test results for a more effective analysis of dielectric properties on avionic components Solar Panel Testing Simplified – Designed with PV testing in mind, the 950i Series uses pico-amp resolution to detect minute defects in solar cells 3 Year Extended Warranty – 1 year standard, total of 3 years extended warranty with registration and annual factory calibration. Built-in reliability you can count on for years to come Safety Tested per EN 61010-1. EMC compliant to EN 61326-1 > Each Unit Includes Alligator test leads NIST traceable calibration certificate with no data power cord and operators manual

  • Vitrek 955I

    $3.394

    Product Highlihgts Highest Level of Operator Safety – features include: GFI High speed shut down for earth ground leakage faults, SFI™ Safety Fault Interlock – High speed shut down output for interruption of safety interlock, TLSS™ Test Lead Safety Sense – Clamps DUT chassis near ground by continuously verifying proper connection of test leads prior to and during HV testing, Recessed start switch prevents inadvertent actuation High Power Output – means better drive capability and increased test throughout. With up to 50mA of sourcing current for DC hipot the 95X Series gets heavy duty jobs done fast – available 100mA & 200mA AC drive tackles even the toughest sourcing requirements Wide Range of built-in Voltage Capabilities – Choose from 6.5KVDC, 11KVDC or 15KVDC and 6KVAC, 10KVAC or up to 30KV RMS AC with external option The Fastest Hipot Testers available – Thanks to our Dual Coldfire® microprocessors combined with Dual DSPs to provide Ramp rates up to 50KV/second, dwell times as low as 20mS and overall test times as fast as 3mS in optional Flash mode Expansive Test Sequence Memory holds up to 100 tests with up to 100 steps per test. Tests can be selected via front panel, Ethernet, RS232, Digital I/O or with optional GPIB Ground Bond Test Capability available in three models with output currents from 100mA to 40Amps RMS and test times from 20mS to 1000 seconds or longer 4-Wire Milli-Ohmmeter Function provides fast, accurate 5 digit resistance measurements with resolution down to 100µΩ and range up to 100K ohms Built-in Phase Angle Measurement – allows the measurement and display of both resistive (in-phase) leakage current and reactive (out-of-phase) leakage current caused by capacitive coupling Multi-Dwell Functionality – permits dwells at different voltage levels without having to return to zero between test steps – dramatically simplifying advanced analysis of dielectric properties Ramp High/Dwell Low Current Limits – permits the user to set separate limits for the ramp and dwell providing faster ramp times and lower leakage test limits Ethernet, RS232, Digital I/O, USB Printer & Scanner Control – All Standard Interfaces – Provides the highest level of test automation. GPIB optional High Voltage Scanner Control – up to 256 point switching capability with available 964i HV Scanners. Route voltages up to 15KV and currents up to 40A for multi-point hipot and ground bond tests Dual Dimensional / Test Specific / Broadband Arc Detection. Where lesser testers allow you to set a single, global, amplitude only arc limit – the technologically advanced 95X Series utilizes time & amplitude based arc limits and uniquely applies them to each desired test Pico-Amp Leakage Measurement insures that even the lowest leakage current levels are accurately detected and tera-ohm range IR readings are stable and precise Test Specific Fixture & Cable Compensation – Automatically calibrate out offset errors caused by lead resistance, fixture capacitance and leakage Multi-Mode IR – Insulation Resistance values up to one Tera-ohm can be obtained with precision in your choice of 3 IR test modes – end on time, end on pass or end on fail Continuously Variable IR Test Voltage – Unlike most IR testers which limit you to 3 or 4 discrete test voltages, the 950i Series allows you to select the test voltage you need. Starting as low as 20V all the way to 6.5KV, 11KV or 15KVDC Capacitance Test Modes – For AC & DC hipot and IR provide tightly controlled charge and discharge profiles for superior results on critical solar panel tests and other highly capacitive loads Light Weight Switching Power Supply Design – Better reliability, easier on your back. Compare the 8.2 kg 95X to whatever youve been using 400Hz AC Voltage Withstand Testing provides aviation frequency specific test results for a more effective analysis of dielectric properties on avionic components Solar Panel Testing Simplified – Designed with PV testing in mind, the 950i Series uses pico-amp resolution to detect minute defects in solar cells 3 Year Extended Warranty – 1 year standard, total of 3 years extended warranty with registration and annual factory calibration. Built-in reliability you can count on for years to come Safety Tested per EN 61010-1. EMC compliant to EN 61326-1 > Each Unit Includes Alligator test leads NIST traceable calibration certificate with no data power cord and operators manual

  • Vitrek 957I

    $3.394

    Product Highlihgts Highest Level of Operator Safety – features include: GFI High speed shut down for earth ground leakage faults, SFI™ Safety Fault Interlock – High speed shut down output for interruption of safety interlock, TLSS™ Test Lead Safety Sense – Clamps DUT chassis near ground by continuously verifying proper connection of test leads prior to and during HV testing, Recessed start switch prevents inadvertent actuation High Power Output – means better drive capability and increased test throughout. With up to 50mA of sourcing current for DC hipot the 95X Series gets heavy duty jobs done fast – available 100mA & 200mA AC drive tackles even the toughest sourcing requirements Wide Range of built-in Voltage Capabilities – Choose from 6.5KVDC, 11KVDC or 15KVDC and 6KVAC, 10KVAC or up to 30KV RMS AC with external option The Fastest Hipot Testers available – Thanks to our Dual Coldfire® microprocessors combined with Dual DSPs to provide Ramp rates up to 50KV/second, dwell times as low as 20mS and overall test times as fast as 3mS in optional Flash mode Expansive Test Sequence Memory holds up to 100 tests with up to 100 steps per test. Tests can be selected via front panel, Ethernet, RS232, Digital I/O or with optional GPIB Ground Bond Test Capability available in three models with output currents from 100mA to 40Amps RMS and test times from 20mS to 1000 seconds or longer 4-Wire Milli-Ohmmeter Function provides fast, accurate 5 digit resistance measurements with resolution down to 100µΩ and range up to 100K ohms Built-in Phase Angle Measurement – allows the measurement and display of both resistive (in-phase) leakage current and reactive (out-of-phase) leakage current caused by capacitive coupling Multi-Dwell Functionality – permits dwells at different voltage levels without having to return to zero between test steps – dramatically simplifying advanced analysis of dielectric properties Ramp High/Dwell Low Current Limits – permits the user to set separate limits for the ramp and dwell providing faster ramp times and lower leakage test limits Ethernet, RS232, Digital I/O, USB Printer & Scanner Control – All Standard Interfaces – Provides the highest level of test automation. GPIB optional High Voltage Scanner Control – up to 256 point switching capability with available 964i HV Scanners. Route voltages up to 15KV and currents up to 40A for multi-point hipot and ground bond tests Dual Dimensional / Test Specific / Broadband Arc Detection. Where lesser testers allow you to set a single, global, amplitude only arc limit – the technologically advanced 95X Series utilizes time & amplitude based arc limits and uniquely applies them to each desired test Pico-Amp Leakage Measurement insures that even the lowest leakage current levels are accurately detected and tera-ohm range IR readings are stable and precise Test Specific Fixture & Cable Compensation – Automatically calibrate out offset errors caused by lead resistance, fixture capacitance and leakage Multi-Mode IR – Insulation Resistance values up to one Tera-ohm can be obtained with precision in your choice of 3 IR test modes – end on time, end on pass or end on fail Continuously Variable IR Test Voltage – Unlike most IR testers which limit you to 3 or 4 discrete test voltages, the 950i Series allows you to select the test voltage you need. Starting as low as 20V all the way to 6.5KV, 11KV or 15KVDC Capacitance Test Modes – For AC & DC hipot and IR provide tightly controlled charge and discharge profiles for superior results on critical solar panel tests and other highly capacitive loads Light Weight Switching Power Supply Design – Better reliability, easier on your back. Compare the 8.2 kg 95X to whatever youve been using 400Hz AC Voltage Withstand Testing provides aviation frequency specific test results for a more effective analysis of dielectric properties on avionic components Solar Panel Testing Simplified – Designed with PV testing in mind, the 950i Series uses pico-amp resolution to detect minute defects in solar cells 3 Year Extended Warranty – 1 year standard, total of 3 years extended warranty with registration and annual factory calibration. Built-in reliability you can count on for years to come Safety Tested per EN 61010-1. EMC compliant to EN 61326-1 > Each Unit Includes Alligator test leads NIST traceable calibration certificate with no data power cord and operators manual