Showing 1270–1278 of 1343 results

  • Sonel Test Measurement MRU-200 GPS

    $1.639

    THE MRU-200-GPS OFFERS A VARIETY OF MEASUREMENT METHODS FOR GROUND RESISTANCE AND RESISTIVIY. The MRU-200-GPS is the only meter which can perform all ground resistance measurement methods, 2-pole, 3-pole, 4-pole, and impulse earth impedance methods. Ground resistance using auxiliary electrodes, or with electrodes and clamp for measurements in the presence of multiple ground paths Ground resistance using double clamps when it is not possible to use auxiliary electrodes Impulse ground resistance without disconnecting measured grounding Soil resistivity using Wenner method Leakage current using current clamp or flexible Rogowsky probe Measurement of continuity of equipotential bonding and protective conductors (meets IEC 60364-6-61:2000 section 6.12.2) with auto-zero function and 200 mA current Ground resistance measurement, with 2-pole, 3-pole, or 4-pole methods Leakage current measurement Selective measurement with clamp excludes influence from parallel ground points No opening of rusted conductors needed Impulse ground resistance measurement at 4/10 µs, 8/20 µs, or 10/350 µs Two clamps resistance measurement method without auxiliary test probes GPS coordinates of measurement location are stored with test results Resistance measurement of auxiliary electrodes Measurement of interference voltage and interference frequency Measurement in the presence of interference voltages at 162/3 Hz, 50 Hz, 60 Hz, and 400 Hz Automatic or manual selection of frequency of measuring signal Selection of maximum measuring voltage (25 V and 50 V) Distance between the electrodes noted in meters (m) and feet (ft) Memory storage for 990 measurements Calibration information of test clamp(s) Real-time clock USB interface for PC connection Internal battery with indication of state of charge Backlit LCD graphic display Double insulated meets IEC 61010-1 and IEC 61557 standards CAT IV 300 V

  • Sonel Test Measurement MRU-30

    $577

    The Sonel MRU-30 is a rugged, portable tool for earth ground resistance measurements. Tests can be performed using the 2-pole, 3-pole, 4-pole, or 3-pole with current clamp methods. Additionally, the MRU-30 can perform the current clamp method using two clamps (one to generate, and one to measure current) for situations when test electrodes cant be used. The MRU-30 provides measurements of soil resistivity, continuity measurement of protective and equipotential conductors, interference voltages, and with current clamp leakage current. Robust and weatherproof (IP65) protection against ingress of dust and water Ergonomic casing small, light-weight, convenient for carrying and field work Built-in rechargeable battery can be recharged from an outlet or 12V Car socket Clear on-screen display to view results Safety alerts user of possible dangers and irregularities before and after the measurement User can use choose between measurement methods Test leads, test electrodes, and power adapter are included

  • Sonel Test Measurement SRP-50K0-100GO

    $13.338

    The SRP-50k0-100GO calibrator is a source of high resistance, used as a standard in calibration and tests of analogue and digital insulation resistance meters. The resistance set by the calibrator can be maintained for long periods under external direct voltage up to 2500 V, provided that the current in the measuring circuit does not exceed 1.5 mA. The required resistance is set by the user using the calibrators touch keypad, or via an external PC application. The required value is set automatically thanks to the switching of a precise resistance matrix. A controlling processor calculates the required combination of resistors, ensuring adequate resistance precision. Software The SRP software is used to connect the SRP-50k0-100GO calibrator with a PC. The software is easy to use and is a useful tool for testing of devices by means of the calibrator. The calibrator connects to a computer via the USB port. Remote control of the calibrator Create and save the automatic programs to check the tested devices Set the keypad lock and time to sleep mode Change the display brightness and keypad tones Software language selection Calibrator software update from the PC via the USB interface > Each Unit Includes CD with the SRP software 1.8 m test lead with 5kV banana plugs, blue 1.8 m test lead with 5kV banana plugs, red 2.2 m shielded cable with banana plugs, black Operating manual Power cord

  • Sonel Test Measurement SRP-50K0-10GO

    $10.499

    The SRP-50k0 10GO calibrator is a source of high resistance, used as a standard in calibration and tests of analogue and digital insulation resistance meters. The resistance set by the calibrator can be maintained for long periods under external direct voltage up to 2500 V, provided that the current in the measuring circuit does not exceed 1.5 mA. The required resistance is set by the user using the calibrators touch keypad, or via an external PC application. The required value is set automatically thanks to the switching of a precise resistance matrix. A controlling processor calculates the required combination of resistors, ensuring adequate resistance precision. Software The SRP software is used to connect the SRP-50k0-10GO calibrator with a PC. The software is easy to use and is a useful tool for testing of devices by means of the calibrator. The calibrator connects to a computer via the USB port. Remote control of the calibrator Create and save the automatic programs to check the tested devices Set the keypad lock and time to sleep mode Change the display brightness and keypad tones Software language selection Calibrator software update from the PC via the USB interface > Each Unit Includes: CD with the SRP software 1.8 m test lead with 5kV banana plugs, blue 1.8 m test lead with 5kV banana plugs, red 2.2 m shielded cable with banana plugs, black Operating manual Power cord

  • Sonel Test Measurement SRP-50KO-5TO

    $9.370

    The SRP-50k0-5TO calibrator is a source of high resistance, used as a standard in calibration and tests of analogue and digital insulation resistance meters. The resistance set by the calibrator can be maintained for long periods under external direct voltage up to 5000 V, provided that the current in the measuring circuit does not exceed 3 mA. The required resistance is set by the user using the calibrators touch keypad, or via an external PC application. The required value is set automatically thanks to the switching of a precise resistance matrix. A controlling processor calculates the required combination of resistors, ensuring adequate resistance precision. Software The SRP software is used to connect the SRP-50k0-5T0 calibrator with a PC. The software is easy to use and is a useful tool for testing of devices by means of the calibrator. The calibrator connects to a computer via the USB port. Remote control of the calibrator Create and save the automatic programs to check the tested devices Set the keypad lock and time to sleep mode Change the display brightness and keypad tones Software language selection Calibrator software update from the PC via the USB interface > Each Unit Includes: CD with the SRP software 1.8 m test lead with 5kV banana plugs, blue 1.8 m test lead with 5kV banana plugs, red 2.2 m shielded cable with banana plugs, black Operating manual Power cord

  • Sonel Test Measurement TDR-410

    $795

    The TDR-410 is a Time-Domain-Reflectometer (TDR) that detects breaks, short circuits, moisture damage, and changes in impedance of cables, and locates fault position. The backlit display gives automatic indication of the type of fault and the distance to the fault. Power cables Copper telecom cables Coaxial cables Wiring infrastructures Automatic or manual operation modes Scan automatically or manually trigger Single measurements triggered manually Continuous scanning operation Automatic fault location (AFL) Range and sensitivity can be set manually or automatically Maximum length of cable up to 4000 m / 14000 ft (2.5 miles) “Dead zone” measurement limited to 0.5 m / 1.64 ft Adjustable impedance matching Propagation coefficient adjustment 1% to 99% 2.5” backlit LCD screen Waterproof, IP 54 / NEMA 3 rugged case construction Small size and weight Low power usage – up to 30 hours of operation on 4 AA batteries

  • Sonel Test Measurement TKF-12

    $555

    Type of insulation: double, according to EN 61010 1 Measurement category: CAT III 600 V acc. to EN 61010 1 Protection class acc. to EN 60529: IP42 Rated phase-to-phase voltage range: 120 to 690 V AC Maximum operation phase-to-phase voltage: 760 V AC Frequency range: 10 to 70 Hz Operating temperature: 14 F to 113 F / -10 to 45°C Storage temperature: -4 F to 140 F / -20 to 60°C Power supply: from the tested electrical installation, up to 15 min for max. voltage Dimensions: 5.1 x 2.8 x 1.4 / 130 x 70 x 35 mm Weight (without test leads): approx. 0.44 lbs / 200g

  • Sonel Test Measurement TKF-13

    $98

    Type of insulation: double, according to EN 61010 1 Measurement category: CAT III 600 V acc. to EN 61010 1 Protection class acc. to EN 60529: IP42 Rated phase-to-phase voltage range: 120 to 690 V AC Maximum operation phase-to-phase voltage: 760 V AC EMF motors voltage range: 1 to 760 V AC Frequency range: 2 to 70 Hz Operating temperature: 14 F to 113 F / -10 to 45°C Storage temperature: -4 F to 140 F / -20 to 60°C Power supply: alkaline battery 6LR61 (9 V) Dimensions: 5.1 x 2.8 x 1.4 / 130 x 70 x 35 mm Weight: approx. 0.55 lbs / 250g Diode flashing time of battery state: approx. 1 s Function auto-off: 5 min

  • Static Solutions CB-9500

    $188

    The Static Solutions Ohm-Stat™ Calibration Box CB-9500 is for use with either the Static Solutions Ohm-Stat™ CT-8700, the CT-8900 or for constant monitors so that you can perform your own NIST certified calibrations. The calibration box itself must be recertified after 1 year to still be in compliance for NIST certification testing. Includes NIST certificate Tests all electrical ranges Product conforms to the ESD S.20.20 spec standards