  • Yokogawa CL340

    $167

    Method of detection Mean value Display LCD(Digital display:3999 counts) Response Time Approx. 2 seconds Range Switching Manual-range Data Hold On all range Peak Hold On all range Ambient temperature and humidity 0 to 40 deg.C, 85% RH or less (no condensation) Temperature Coefficient Influence of external magnetic field 10mA or less in proximity to a 15mm-dia conductor carrying 100A Influence of conductor position 40/400mA range:Within 5dgt at every part inside the jaw400A range 0 to 250A:Within ±0.5%rdg ±5dgt at every part inside the jaw section Influence of residual current 12mA or less in proximity to a 10mm-dia conductor carrying 100A Safety Standard Conforms EN 61010-1, EN61010-2-032 Circuit Voltage 300Vrms or less Withstanding Voltage 3.7kV AC for one minute Power Supply R0-3(UM-4) × 2 or LR03 × 2 Battery Life Approx. 40 hours (continuous) Consumed Current Approx. 13mA Auto power-off Approx. 10 minutes Diameter of measurable conductor 40mm at maximum Dimensions Approx. 81(W) × 185(H) × 40(D)mm Weight Approx. 270g > Each Unit Includes Users manual (IM CL340) Batteries Carrying case (93030)

  • Yokogawa CL345

    $244

    True RMS display Auto power-off Manual range switching Approved for comformity to safety standards EN61010-1 (CAT. III 300 V) 40mm in diameter of measurable conductor > Each Unit Includes Users Manual Batteries Carrying Case (93030)

  • Yokogawa CL420

    $346

    0.2% Accuracy and 0.01 mA Resolution from 0-20 mA DC mA Measurement and % of Span for 4-20 mA Dual LCD Numeric Display. LED Torch Light Data Hold Function 6mm Clamp Diameter Analog Output Available Display 4-digit LCD Numeric display Response time Approx. 1.5 seconds (2.5 seconds when across the range) Range switching Auto range Operating temperature and humidity -10°C to 50°C 80% RH or less (no condensation) Safety Standards EN61010-1, EN61010-2-030, EN61010-2-032 Withstanding voltage 2.21kV AC for 5 seconds (between the core and the case) Power supply Four AA-size alkaline batteries (1.5V LR6) Battery life Approx. 60hrs (continuous) backlight off and LED light off Other functions Data hold, Zero adjust function, Auto power off, LED Torch light, Back light display, Illuminant panel External dimensions and weight 61 (W) Î 111 (H) Î 40 (D) mm Approx. 290g (including batteries) > Each Unit Includes User’s Manual Batteries Soft case

  • Yokogawa CW10

    $142

    Basic functionality of a clamp-on tester, digital multimeter and power monitor into one tool Current and voltage measurement rating is 600 A AC/DC and 1000 V AC/DC respectively with power measurement ratings upto 600 kW AC/DC Measures AC and DC Current, AC and DC Volts, Power, Power Factor, Total Harmonics Distortion & Individual Harmonics (fundamental wave to 25th), Resistance and Frequency True RMS measurement 9999 Count with White Backlit LED and Bar Graph Display Phase Rotation Voltage Detection Easy Operation with Joystick Auto Power Off Continuity Beeper CAT IV 600 V, CAT III 1000 V Safety Rating > Each Unit Includes Test leads Carrying case User’s manual Battery