Fluke TLK1550-RTLC
$1693 test leads (red, black, green) connected to low-leakage probes 3 alligator clips (red, black, green) Test Leads extend to 25 26mm maximum jaw opening Integral test lead set for the fluke 1550B/1550C/1555 MegaohmMeter
Showing 190–198 of 274 results
3 test leads (red, black, green) connected to low-leakage probes 3 alligator clips (red, black, green) Test Leads extend to 25 26mm maximum jaw opening Integral test lead set for the fluke 1550B/1550C/1555 MegaohmMeter
Measures AC current AC voltage measurement with digital low pass filter for accurate readings on variable frequency drives Also measures DC voltage, resistance, capacitance and frequency Tests continuity and diodes Flashlight inside clamp jaw for easier work in dark locations Backlight & relative mode for added versatility AmpTip™ increases accuracy on small wires and low current Two voltage detection modes non-contact or using a single test lead Data hold Recording of Maximum, Minimum, and Average readings Lifetime warranty Amperage Measurement : 60, 600, 1000 Amps AC Display : LCD, 6000 Count Frequency Rating : Voltage: 50/60 Hz. Current: 40 to 400 Hz Jaw Opening : 2.0 (51 mm) Measurement Category : CAT III 1000V, CAT IV 600V Replacement Part : TSG-3 test leads, TC-30 carrying case Resistance Measurement : 600, 6k, 60k Ohms Standard : CAT IV, C/US UL Listed, CE True Power : AC True RMS Voltage Measurement : 600, 1000 Volts AC/DC > Each Unit Includes (2) 1.5V AA batteries Test leads Carrying case
Measures AC current AC voltage measurement with digital low pass filter for accurate readings on variable frequency drives Also measures DC voltage, resistance and frequency Tests continuity and diodes AmpTip™ increases accuracy on small wires and low current Two voltage detection modes non-contact or using a single test lead Data hold Recording of Maximum, Minimum, and Average readings Lifetime warranty Amperage Measurement : 60, 600 Amps AC Display : LCD, 6000 Count Frequency Rating : Voltage and AmpTip™ current: 50/60 Hz. High current: 50 to400 Hz Jaw Opening : 1.18 (30 mm) Measurement Category : CAT III 600V, CAT IV 300V Replacement Part : TSG-3 test leads, TC-10 carrying case Resistance Measurement : 600, 6k, 60k Ohms Standard : CAT III, C/US UL Listed, CE True Power : AC True RMS Voltage Measurement : 600 Volts AC/DC > Each Unit Includes (2) 1.5V AAA batteries Test leads, Carrying case
Measures AC DC current and DC microamps AC and AC DC voltage measurements with digital low pass filter for accurate readings on variable frequency drives Also measures DC voltage, resistance, capacitance, temperature and frequency Tests continuity and diodes Phase Sequence & Motor Rotation tests Peak-RMS measures motor in rush current Flashlight inside clamp jaw for easier work in dark locations Backlight & relative mode for added versatility AmpTip™ increases accuracy on small wires and low current Two voltage detection modes non-contact or using a single test lead Data hold Recording of Maximum, Minimum, and Average readings Crest (peak hold) feature captures current or voltage peaks as short as 5 milliseconds Lifetime warranty Amperage Measurement : 60, 600, 1000 Amps AC DC Display : LCD, 6000 Count Frequency Rating : Voltage: 50/60 Hz. Current: 40 to 400 Hz Jaw Opening : 2.0 (51 mm) Measurement Category : CAT III 1000V, CAT IV 600V Replacement Part : 02714 test leads and clips, TC-30 carrying case Resistance Measurement : 600, 6k, 60k Ohms Standard : CAT IV, C/US UL Listed, CE True Power : AC DC True RMS Voltage Measurement : 600, 1000 Volts AC DC > Each Unit Includes (2) 1.5V AA batteries Test leads and clips Carrying case
Measures AC DC current and DC microamps AC and AC DC voltage measurements with digital filter low pass for accurate readings on variable frequency drives Also measures DC voltage, resistance, capacitance, temperature and frequency Tests continuity and diodes Phase Sequence & Motor Rotation tests Peak-RMS measures motor in rush current Backlight & relative mode for added versatility AmpTip™ increases accuracy on small wires and low current Two voltage detection modes non-contact or using a single test lead Data hold Recording of Maximum, Minimum, and Average readings Lifetime warranty Amperage Measurement : 60, 600 Amps AC DC Display : LCD, 6000 Count Frequency Rating : Voltage and AmpTip™ current: 50/60 Hz. High current: 50 to 400 Hz Jaw Opening : 1.18 (30 mm) Measurement Category : CAT III 600V, CAT IV 300V Replacement Part : 02714 test leads and clips, TC-10 carrying case Resistance Measurement : 600, 6k, 60k Ohms Standard : CAT III, C/US UL Listed, CE True Power : AC DC True RMS Voltage Measurement : 600 Volts AC DC > Each Unit Includes (2) 1.5V AAA batteries Test leads and clips Carrying case
AC Clamp Meter Set (3280-10F with AC Flexible Current Sensor CT6280) Mean Value Rectification Pocket Size Broad Operating Temperature Range (-25° C to 65°C) Mechanically Robust Design (can withstand a 1M drop onto a concrete floor) > > Each Unit Includes 9398 Carrying Case L9208 Test Leads CR2032 Battery CT6280 AC Flexible Current Sensor >
Easily monitor leak current fluctuations Wide bandwidth, 5 Hz to 15 kHz (Waveform output) High-sensitivity with a full scale of 10 mA (Resolution:10 µA) High-accuracy at ±1 % True RMS measurement Analyzer functions for filtering and output signals AC Current range: 10.00 mA to 200 A AC, 5 ranges (±1.0 % rdg. ±5 dgt. at 50 or 60Hz), and 200 A AC, 1 ranges (±1.5 % rdg. ±5 dgt. at 50 or 60Hz) Effective value rectifier Frequency measurement: 100.0 or 1000 Hz, 2 ranges (±0.3 % rdg. ±1 dgt.) AC Voltage range: None Filter function: 180 Hz ±30 Hz /-3 dB Analog output DC, or AC 1 V /f.s. Level output: with REC mode Waveform output: with MON mode Frequency characteristics (at AC current / voltage): 40 to 2 kHz Display section Digital/1000 dgt. (Bar graph/35 seg.) Sampling rate: 2 or 4 times/sec (Slow: 1 time/3 sec) Crest factor (RMS) 2.5 (1.5 at 200 A range) Max. circuit voltage: 300 V AC rms (insulated wire) Power supply: 6F22(006P) × 1 (Continuous use 40 hours) or AC adapter Core jaw diameter: Ø40 mm (1.57 in) Dimensions: 62 mm (2.44 in) W × 225 mm (8.86 in) H × 39 mm (1.54 in) D Mass: 400 g (14.1 oz) > Each Unit Includes Carrying case 9399 Hand strap
Analysis for DC and AC distorted waves 200 Arms, clamp aperture: 33 mm (1.30 in) dia. Inrush current crest value RMS value of full-wave rectified waveforms Waveform and harmonic analysis AC Current range AC (RMS or Peak value): 20.00 or 200.0 A AC, 2 ranges (±1.3 % rdg. ±3 dgt. at 50 or 60Hz), AC DC (RMS or Peak value) 20.00 or 200.0 A AC, 2 ranges (±1.3 % rdg. ±13 dgt. at 50 or 60Hz) Effective value rectifier DC Current range: DC (Average or Peak value) 20.00 or 200.0 A DC, 2 ranges (±1.3 % rdg. ±3 dgt.) AC Voltage range: AC (RMS or Peak value) 30.00 to 600 V AC, 3 ranges (±1.0 % rdg. ±3 dgt. at 50 or 60Hz), AC DC (RMS or Peak value)30.00 to 600 V AC, 3 ranges (±1.0 % rdg. ±7 dgt. at 50 or 60Hz) Effective value rectifier DC Voltage range: DC (Average or Peak value) 30.00 to 600 VDC, 3 ranges (±1.0 % rdg. ±3 dgt.) Frequency: 10 to 1000 Hz Mode: Max./Min./AVE./RMS Record mode/Auto-off Analog output: DC, or AC 1 V/f.s. Level output: with REC mode Waveform output: with MON mode Frequency characteristics (at AC current / voltage): DC, 10 to 2 kHz Display section Current/2500 dgt. Voltage/3750 dgt. Bar graph/35 seg. Sampling rate: 2 or 4 times/sec (Slow: 1 time/3 sec) Crest factor (RMS) 2.5 (1.7 at 600 V range), 1.5 (200 A range) Max. circuit voltage: 600 V AC rms (insulated wire) Power supply: 6F22(006P) × 1 (Continuous use 25 hours) or AC adapter Core jaw dia. Ø 33 mm(1.30 in) Dimensions: 62 mm (2.44 in) W × 230 mm (9.06 in) H × 39 mm (1.54 in) D Mass: 460 g (16.2 oz) > Each Unit Includes Test lead 9207-10 Carrying case 9399 Hand strap
Compact & easy, one-touch maintenance on all types of AC/DC equipment The 3287 can handle even cogenerator/inverter energy-saving equipment A slim core of only 10 mm(0.39 in) for easy clamping even in crowded wiring AC Current range 10.00 or 100.0 A AC, 2 ranges (±1.5 % rdg. ±5 dgt. at 50 or 60Hz), Effective value rectifier DC Current range 10.00 or 100.0 A AC, 2 ranges (±1.5 % rdg. ±5 dgt.) AC Voltage range 4.200 to 600 V AC, 4 ranges (±2.3 % rdg. ±8 dgt. at 50 or 60Hz), Effective value rectifier DC Voltage range 420.0 mV to 600 V DC, 5 ranges (±1.3 % rdg. ±4 dgt.) Other functions Resistance: 420.0 to 42.00 M-ohm, 6 ranges, Accuracy: ±2.0 % rdg. ±4 dgt. (at 420 to 420 k-ohm range), Continuity: 420.0 ohm (Buzzer sounds at approx. 50 ohm or less) Frequency characteristics (at AC current / voltage) AC current: 10 to 1 kHz, AC voltage: 30 to 500 Hz Display section Digital / LCD, maximum 4199 dgt. Sampling rate 2.5 times/sec Crest factor (RMS) 2.5 or less (150 A, 1000 V maximum) Max. circuit voltage 600 V AC rms (insulated wire) Power supply CR2032 (3 VDC) × 1, Continuous use 25 hours Core jaw dia. Ø 35 mm(1.38 in) Dimensions, mass 57 mm(2.24 in)W × 180 m (7.09 in)H × 16 mm(0.63 in)D, 170 g (6.0 oz) > Each Unit Includes Test Lead Carrying Case