Showing 154–162 of 274 results
-
$600
Exclusive VIP Kit includes FREE 1450-C Pelican Case. You dont have to break the loop to make 4-20 mA signal measurements. Features Best in class 0.2 % accuracy 0.01 mA resolution and sensitivity Measure 4 to 20 mA signals without ”breaking the loop” Measure mA signals for PLC and control system analog I/O Dual backlit display with both mA measurement and percent of 4 to 20 mA span Measurement Spotlight illuminates hard to see wires in dark enclosures Detachable clamp with extension cable for measurements in tight locations Measure 10 to 50 mA signals in older control systems using the 99.9 mA range Automatically change the 4 to 20 mA output for remote testing Power saving features, auto-off, backlight timeout extend battery life Hold function captures and displays changing measurements Measure 4 to 20 mA signals with in-circuit measurement Simultaneous mA in-circuit measurement with 24V loop power for powering and testing transmitters Source 4 to 20 mA signals for testing control system I/O or I/Ps mA output linear ramp or 25% step output > Each Unit Includes FREE 1450-C Pelican Case Soft carrying case Test leads Alligator clips Hanging strap User’s manual
-
$757
The Fluke 773 milliamp clamp meter is accurate and versatile. It saves time and money by measuring 4–20 mA signals five times faster than with traditional DMMs, and without breaking the loop. Fluke 773 Overview Need more hours in your day? Save time by NOT breaking the loop on 4-20 mA signal measurements. Are you spending time: Taking mA measurements by removing a wire and breaking the loop Calling the control room to isolate a loop Testing analog input/output on a console Troubleshooting devices with mA inputs and outputs Repairing intermittent or erratic 4-20 mA loops Going back to the shop to get extra tools > If you need more time in your busy day take a good look at the Fluke 773 mA Clamp Meters. Its designed to save you time, and money, by eliminating time wasting activities. Now you can troubleshoot and repair 4-20 mA loops without breaking the loop or bringing down the system. Fluke 773 Features Best in class 0.2 % accuracy 0.01 mA resolution and sensitivity Measure 4 to 20 mA signals without breaking the loop Measure mA signals for PLC and control system analog I/O Dual backlit display with both mA measurement and percent of 4 to 20 mA span Measurement Spotlight illuminates hard to see wires in dark enclosures Detachable clamp with extension cable for measurements in tight locations Measure 10 to 50 mA signals in older control systems using the 99.9 mA range Automatically change the 4 to 20 mA output for remote testing Power saving features, auto-off, backlight timeout extend battery life Hold function captures and displays changing measurements Measure 4 to 20 mA signals with in-circuit measurement Simultaneous mA in-circuit measurement with 24V loop power for powering and testing transmitters Source 4 to 20 mA signals for testing control system I/O or I/Ps mA output linear ramp or 25% step output DC voltage measurement to verify 24V power supplies or voltage I/O signals Source DC voltage to test input devices that accept a 1-5V or 0 to 10V signals Scaled mA output provides a continuous mA signal that corresponds to the 4 to 20 mA signal measured by the mA clamp mA in/out: simultaneously measure the mA signal with the clamp and source a mA signal Voltage output linear ramp or 25% step output > Each Fluke 773 Includes Four AA alkaline batteries (installed) Soft carrying case TL75 test leads AC 72 detachable clip TL 940 mini hook test leads Instruction sheet Hanging tool with hook and loop strap
-
$757
You dont have to break the loop to make 4-20 mA signal measurements. Exclusive VIP Kit includes FREE Pelican 1450-C Hard case (15 x 10.5 x 6), Black and DC Voltage Detector, 6-50 VDC. FREE Pelican 1450-C Hard case (15 x 10.5 x 6), Black and DC Voltage Detector, 6-50 VDC Exclusively from Transcat with purchase of a 773-VIP > Overview Need more hours in your day? Save time by NOT breaking the loop on 4-20 mA signal measurements. Are you spending time: Taking mA measurements by removing a wire and breaking the loop Calling the control room to isolate a loop Testing analog input/output on a console Troubleshooting devices with mA inputs and outputs Repairing intermittent or erratic 4-20 mA loops Going back to the shop to get extra tools > If you need more time in your busy day take a good look at the Fluke 773 mA Clamp Meters. Its designed to save you time, and money, by eliminating time wasting activities. Now you can troubleshoot and repair 4-20 mA loops without breaking the loop or bringing down the system. Features Best in class 0.2 % accuracy 0.01 mA resolution and sensitivity Measure 4 to 20 mA signals without breaking the loop Measure mA signals for PLC and control system analog I/O Dual backlit display with both mA measurement and percent of 4 to 20 mA span Measurement Spotlight illuminates hard to see wires in dark enclosures Detachable clamp with extension cable for measurements in tight locations Measure 10 to 50 mA signals in older control systems using the 99.9 mA range Automatically change the 4 to 20 mA output for remote testing Power saving features, auto-off, backlight timeout extend battery life Hold function captures and displays changing measurements Measure 4 to 20 mA signals with in-circuit measurement Simultaneous mA in-circuit measurement with 24V loop power for powering and testing transmitters Source 4 to 20 mA signals for testing control system I/O or I/Ps mA output linear ramp or 25% step output DC voltage measurement to verify 24V power supplies or voltage I/O signals Source DC voltage to test input devices that accept a 1-5V or 0 to 10V signals Scaled mA output provides a continuous mA signal that corresponds to the 4 to 20 mA signal measured by the mA clamp mA in/out: simultaneously measure the mA signal with the clamp and source a mA signal Voltage output linear ramp or 25% step output > Each Unit Includes FREE 1450-C Case FREE DC Voltage Detector Soft carrying case Test leads Alligator clips Hanging strap Users manual
-
$154
The Fluke 902 FC True-rms HVAC Clamp Meter, a wireless Fluke Connect®-enabled meter, improves the productivity of HVAC technicians in the field. The rugged dual rated CAT III, 600 /CAT IV, 300 V meter performs the essential measurements of HVAC systems — microamps for testing pilot light sensors, resistance up to 60 kilohms, AC current, AC/DC voltage, capacitance and contact temperature — eliminating the need to carry multiple tools. Its small body is easy to hold and the jaw fits perfectly in tight work spaces. 200 µA DC current measurements to measure flame rod Extended resistance range to measure thermistors up to 60kΩ Capture flue gas temperature Measure start and run motor capacitors Measure performance of variable frequency drives Fluke Connect connects your meter to your phone through Bluetooth to help you get more done faster and safer Read measurements on your phone at a safe distance, wearing less PPE while your meter takes all the risks Troubleshoot better by instantly trending and monitoring measurements live on your phone screen Create and email reports right from the field. Report not enough? Fluke Connect has ShareLive video calls that stream live video and measurements in the same screen Dont stop to write down results, save them directly from your meter to your phone with the press of a button 600 A ac current measurement 600 V ac and dc voltage measurement Temperature measurement from -10 °C to 400 °C (14 °F to 752 °F) 1000 µF capacitance measurement DC Current measurement to 200 µA True-rms voltage and current for accurate measurements on non-linear signals Resistance measurement to 60 kΩ Min and max recording to capture variations automatically CAT III 600V, CAT IV 300V safety rating TPAK magnetic strap (optional) allows you to conveniently hang the meter while using the probes Ergonomic design fits in your hand and can be used while wearing personal protective equipment Large, easy-to-read backlit display Three-year warranty Soft carrying case
-
$253
Measures up to 2000 A dc Large jaw size (64 mm) for measuring large, high current conductors Logging function for the recording and saving up to 65,000 measurements
-
$307
Measure 4 to 20 mA signals without breaking the loop Detachable clamp with extension cable for measurements in tight locations Use as a standalone meter or as part of the system Logging function for the recording and saving up to 65,000 measurements
-
$697
If you want a very stable thermometer from –200 °C to 670 °C and are particular about the calibration, then look no further than the 5609 Secondary Reference PRT. Its short-term stability at the triple point of water is only ± 7 mK and its one-quarter inch (6.23mm) diameter lets you get accurate measurements in only 100 mm of immersion. The 5609 comes with a one-quarter inch (6.35 mm) diameter sheath in lengths of 12 inches, 15 inches, and 20 inches, or with a 6 mm diameter in lengths of 300 mm, 400 mm, or 500 mm. When looking for improved response time and reduced stem effect in shallow immersion, look for small diameter probes, because the measurement error called stem effect is caused by the diameter of the stem rather than the length of the stem. –200 °C to 670 °C (100 mm minimum immersion) Dry-well reference with 90 ° bend 20 in x 1/4 in lead wire (cable) 6 ft banana plugs
-
$2.043
Range to 661°C Meets all ITS-90 requirements for resistance ratios Rtp drift <, 20mK after 500 hours at 661°C Clibrated accuracy of ± 0.006 °C at 0 °C Banana plugs
-
$1.414
Secondary Standard PRT Temperature Sensors High-temp PRT, 25.5Ω Temperature Range: –200 °C to 661 °C Handle Temp: 0 °C to 80 °C RTPW: 25.5Ω (±0.5Ω) W(Ga): ³ 1.11807 Calibration Uncertainty (k=2): ±0.006 °C at –200 °C ±0.004 °C at 0 °C ±0.009 °C at 420 °C ±0.014 °C at 661 °C Stability: ±0.003 °C Long-Term Drift: <, 0.03 °C/500 hours at 661 °C Immersion: At least 12.7 cm (5 in) recommended Sheath: Inconel™ 600 Lead Wires: 4-wire Super-Flex PVC, 22 AGW Termination: 5 Pin DIN for 1502A Size: 0.25 dia. x 15