Showing 10–18 of 53 results

  • Amprobe LAN-1

    $50

    Test pin configuration for: 10/100 base -T cable 10 base-2 cable RJ45 modular cables AT&T 258A cable EIA / TIA 568A/568B cables Token Ring Cable Verify the cable wiring for continuity, opens, shorts or incorrect wiring Test installed cable on wall plate or the patch panels by using the Remote Termination module Perform Loopback Test or Remote Test Buzzer sound warning for error condition in cable Two sets of LED lights for Source and Test indication Maximum line length: &gt, 300 meters Connector types: RJ45, BNC Battery Life: Approx 20 hours. (Alkaline battery) Size: 130 x 56 x 38 mm (5.1 x 2.2 x 1.5 in.) Weight: 1.26 kg (0.6 lb) Safety: CE EMC Display: 18 LEDs: 9 Red and 9 Green, 9 LEDs on Remote module Battery: Standard 9-volt battery, NEDA 1604A, JIS 006P, IEC 6F22 Low Battery Indicator: The LED indicator will not turn ON when BATT button is pushed Operating environment: 0 to 40°C (32 to 104°F), 10 to 70% RH > Each Unit Includes Remote Terminator 1 ea RJ45 to female BNC cable 1 ea RJ45 to male BNC cable 1 ea 1 RJ45 to RJ45 cable 1 ea female BNC to female BNC connector 9 volt battery Users Manual

  • Amprobe MLS55-3

    $350

    Optional Accessory for the AT-3500 wire / pipe locator, used to pinpoint places in pipes, ducts, etc. Can be inserted to the pipe/duct using tandard fish tape or duct rodder (not upplied) The AT-5000 series receiver is used to inpoint location of the sonde transmitter inside the pipe/duct Accommodates pipes over 2 (5 cm) in diameter

  • Amprobe UAT-610

    $2.043

    Find utilities before you dig with the UAT-600 Series Underground Utilities Locator kits. Accidentally hitting a utility line during a project can lead to costly repairs and create hazardous public safety situations. Digging in the wrong place can also lead to unnecessary delays and costs for your project, and ultimately, your company. Avoid this disruption with the rugged and durable Amprobe UAT-600 Series, designed to accurately pinpoint underground utilities and buried services up to 20 feet deep. Designed for electricians with a CAT IV 600 V rating, the locating kits come complete and ready for use with a Transmitter, Receiver, test lead kit, batteries and additional fuses, all in a mobile, protective duffle bag. The UAT-620 kit also includes a Signal Clamp for transmitting a signal when it is not possible to make electrical contact with the cable to be traced. For applications where ground fault locating is required, use the UAT-600 Transmitter in combination with the optional A-Frame accessory. Multiple tracing modes allow you to locate and trace energized and de-energized utilities in a variety of applications The intuitive Transmitter automatically chooses the correct locating function based on the connected accessory and includes selectable 8/33 kHz frequencies The Receiver’s high-contrast display allows for clear viewing in full sunlight and features an automatic backlight for shaded and dark areas Rated CAT IV 600 V, ensuring safety when working with energized cables Semi-automatic gain control quickly detects tracing signal and allows precise adjustment of the Receiver sensitivity Accurate depth measurement to 20 ft Rugged, durable construction: water and dust resistant to IP54 and drop proof to 3.28 ft (1 m) Use the Signal Clamp to induce a signal without making electrical contact (included with the UAT-620 kit) Ground fault locating with the optional A-Frame accessory Comes as a complete kit, ready for use > Main applications Locate energized 50/60 Hz cables carrying current Identify the location of all metallic utilities: pipes*, energized and de-energized cables Trace individual pipes* or cables (energized or de-energized) *Tracing of non-metallic pipes and conduits is possible after inserting metal fish tape or cable > Three testing modes for wide range of applications Passive power mode (50/60 Hz) – tracing energized lines conducting current (no Transmitter necessary) Passive radio mode (RF) – using surrounding radio waves to trace underground utilities (no Transmitter necessary) Active mode using UAT-600-T Transmitter > Three active modes using the UAT-600-T Transmitter Induction – the Transmitter will automatically start to radiate a signal around it using an internal antenna, used for tracing individual cables where there is no access to the line to connect test leads or a clamp Direct connection with test leads – the most reliable method to trace individual cable or a pipe Clamp (Included in the UAT-620 kit, optional for the UAT-610 kit) – provides an efficient and safe method of applying a locate signal to a cable, where it is not possible/safe to gain access to a cable for making an electrical contact > Special applications 2 frequency options: 8 kHz and 33 kHz Locate non-metallic pipes and sewer lines Take depth and current measurements Measure voltage, resistance and output current Advanced locating with two people Locate ground faults with the AF-600 A-Frame accessory > Customers who use Amprobe Underground Locators Commercial and Residential Construction Contractors Water, Gas and Electric Installation & Repairs Crews Pipe Laying Contractors Cable TV & Telecommunication Companies Electricians & General Contractors > AF-600 A-Frame (Optional accessory not included in UAT-600 Series Kits) The AF-600 A-Frame cable ground fault finder is specifically designed for the Amprobe UAT-600 series. In combination with the Transmitter, it will pinpoint the place where a cable metal conductor (either a sheath or a metallic conductor of the wire) touches the ground. It can also detect other conductors to ground faults such as pipeline coating defects. SC-600 Signal Clamp (Included in the UAT-620 Kit only) The Signal Clamp accessory provides an efficient and safe method of applying a locate signal to a cable, enabling the Transmitter to induce a signal through the insulation into the wires or pipes. The clamp works on low impedance closed circuits only. Each Unit Includes UAT-600-R Receiver UAT-600-T Transmitter CC-UAT-600 Carrying Case TL-UAT-600 Test Leads Kit Black test lead with detachable black alligator clip Red test lead with permanently attached red alligator clip Ground stake > FP-UAT-600 Replacement Fuse User Manual Quick Reference Guide 1.5 V AA (IEC LR6) Batteries (Receiver) D-Cell Batteries (Transmitter)

  • Amprobe UAT-620

    $2.124

    Find utilities before you dig with the UAT-600 Series Underground Utilities Locator kits. Accidentally hitting a utility line during a project can lead to costly repairs and create hazardous public safety situations. Digging in the wrong place can also lead to unnecessary delays and costs for your project, and ultimately, your company. Avoid this disruption with the rugged and durable Amprobe UAT-600 Series, designed to accurately pinpoint underground utilities and buried services up to 20 feet deep. Designed for electricians with a CAT IV 600 V rating, the locating kits come complete and ready for use with a Transmitter, Receiver, test lead kit, batteries and additional fuses, all in a mobile, protective duffle bag. The UAT-620 kit also includes a Signal Clamp for transmitting a signal when it is not possible to make electrical contact with the cable to be traced. For applications where ground fault locating is required, use the UAT-600 Transmitter in combination with the optional A-Frame accessory. Multiple tracing modes allow you to locate and trace energized and de-energized utilities in a variety of applications The intuitive Transmitter automatically chooses the correct locating function based on the connected accessory and includes selectable 8/33 kHz frequencies The Receiver’s high-contrast display allows for clear viewing in full sunlight and features an automatic backlight for shaded and dark areas Rated CAT IV 600 V, ensuring safety when working with energized cables Semi-automatic gain control quickly detects tracing signal and allows precise adjustment of the Receiver sensitivity Accurate depth measurement to 20 ft Rugged, durable construction: water and dust resistant to IP54 and drop proof to 3.28 ft (1 m) Use the Signal Clamp to induce a signal without making electrical contact (included with the UAT-620 kit) Ground fault locating with the optional A-Frame accessory Comes as a complete kit, ready for use > Main applications Locate energized 50/60 Hz cables carrying current Identify the location of all metallic utilities: pipes*, energized and de-energized cables Trace individual pipes* or cables (energized or de-energized) *Tracing of non-metallic pipes and conduits is possible after inserting metal fish tape or cable > Three testing modes for wide range of applications Passive power mode (50/60 Hz) – tracing energized lines conducting current (no Transmitter necessary) Passive radio mode (RF) – using surrounding radio waves to trace underground utilities (no Transmitter necessary) Active mode using UAT-600-T Transmitter > Three active modes using the UAT-600-T Transmitter Induction – the Transmitter will automatically start to radiate a signal around it using an internal antenna, used for tracing individual cables where there is no access to the line to connect test leads or a clamp Direct connection with test leads – the most reliable method to trace individual cable or a pipe Clamp (Included in the UAT-620 kit, optional for the UAT-610 kit) – provides an efficient and safe method of applying a locate signal to a cable, where it is not possible/safe to gain access to a cable for making an electrical contact > Special applications 2 frequency options: 8 kHz and 33 kHz Locate non-metallic pipes and sewer lines Take depth and current measurements Measure voltage, resistance and output current Advanced locating with two people Locate ground faults with the AF-600 A-Frame accessory > Customers who use Amprobe Underground Locators Commercial and Residential Construction Contractors Water, Gas and Electric Installation & Repairs Crews Pipe Laying Contractors Cable TV & Telecommunication Companies Electricians & General Contractors > AF-600 A-Frame (Optional accessory not included in UAT-600 Series Kits) The AF-600 A-Frame cable ground fault finder is specifically designed for the Amprobe UAT-600 series. In combination with the Transmitter, it will pinpoint the place where a cable metal conductor (either a sheath or a metallic conductor of the wire) touches the ground. It can also detect other conductors to ground faults such as pipeline coating defects. SC-600 Signal Clamp (Included in the UAT-620 Kit only) The Signal Clamp accessory provides an efficient and safe method of applying a locate signal to a cable, enabling the Transmitter to induce a signal through the insulation into the wires or pipes. The clamp works on low impedance closed circuits only. Each Unit Includes UAT-600-R Receiver UAT-600-T Transmitter CC-UAT-600 Carrying Case TL-UAT-600 Test Leads Kit Black test lead with detachable black alligator clip Red test lead with permanently attached red alligator clip Ground stake > FP-UAT-600 Replacement Fuse User Manual Quick Reference Guide 1.5 V AA (IEC LR6) Batteries (Receiver) D-Cell Batteries (Transmitter) SC-600 Signal Clamp

  • Eagle Eye Power Solutions GFL-1000

    $4.370

    Two functions in one: Insulation tester and ground fault locator Test and record insulation status of facilities Powerful management DataView Software on PC for data analysis No disconnection of the electrical installation ground fault location is carried out during operation Fast locations for ground fault even when cables are buried Signal-generator with adjustable frequency and voltage Reflects aging status of facilities for further reparation Reduced maintenance and repair costs Compact & rugged design Measuring range V testing: 0.00-1000V, Insulation resistance: 20kO-500MO (250V) 50kohms-1000Mohms (500V) 100 kohms-2000Mohms (1000V) Min resolution Voltage: 0.1V Insulation R: 0.01 Mohms Accuracy Voltage: 1%rdg±8dgt Insulation R: 0.5 Mohm-100 Mohm 5 rdg±6dgt?100 MO: 10%rdg±6dgt Output signal voltage: 0-1000V±10% Frequency: 1-1000Hz Power consumption =4 hours(continuous operation) Memory 32k×8bit Non Volatile SRAM Displaying screen 128×64 pixels LCD Communication USB interface Dimension 14.5L x 11.4W x 9.8H Humidity 80%R.H Testing accuracy =0.25Mohm Sensor aperture 2.3 Battery Li-ion Weight 15.4 lbs. Temperature 23°F to 104°F Power voltage DC 8.4V Jaw opening 2.6 > Each Unit Includes GFL-1000 Main Body Signal Generator Power Adapter Two (2) Signal Testing Leads Two (2) Alligator Clips Punctuation Clip Signal Receiver Two (2) Dual-Range Current Detector Two (2) Batteries Battery Charger Carrying Case

  • Extech 40180

    $55

    Extech Model # 40180 Insulated Inductive probe tip prevents shorting conductors Tests include wire trace, continuity test, clear/busy/ringing line test and tip/ring identification Both alligator test leads and modular phone connectors Selectable continuous or variable tone generation Built in speaker on probe with sensitivity control Output jack for headphones > Each Unit Includes Carrying pouch 9V Batteries

  • Extech CB10

    $47

    Quickly locate 110V to 125VAC Circuit Breakers and Fuses Variable Sensitivity adjustment to pinpoint correct circuit breaker Bright Red and Green LEDs indicates if receptacle is correctly wired or six fault conditions Push button GFCI test Audible and visual circuit breaker indication Convenient storage position for transmitter/receptacle tester Eliminates circuit interruptions UL listed > Each Unit Includes One Receiver One GFCI Transmitter 9V battery for the Receiver

  • Fluke FOS-850

    $240

    A variety of light sources allow you to test different cable lengths One year warranty

  • Fluke Networks CIQ-100

    $768

    Documents that residential cabling systems are defect-free and TIA-570B compliant Qualifies Tests if your existing cabling has the bandwidth to support voice, 10/100/1000 Ethernet, VoIP, or CATV Graphically maps wiring configuration and shows distance to faults with Intelligent Wiremap & TDR Tests all copper cabling media: twisted-pair, coax, and audio cabling Locate and trace cables with IntelliTone digital signaling technology (Requires IntelliTone 200 Digital Probe)