Showing 1–9 of 28 results

  • Yokogawa CA150

    $1.210

    The Yokogawa CA150 simultaneously signals source and measurement operations at the same time, providing an accuracy within 0.02% of the DC voltage range for both functions. With the CA150 you can perform operational checks, regular inspections, maintenance and diagnostics on equipment such as thermocouples, RTDs, process instruments, transmitters, thermostats and signal converters. Highly accurate within 0.02% of the DC voltage range for source and measure Source and measurement can be performed simultaneously. Vertical body with large-screen display Loop power supply function (24 VDC at a load of max 22 mA) It is possible to measure current in the mA range while supplying power. Sink function Sweep functions that allow 3 types of continuous outputs: Step sweep function, Linear sweep function, Program sweep function Auto power-off Approx. 10 minutes, it can be canceled by setting Operating Temperature/Humidity Range 0 to 40?°C, 20 to 80 % RH (no condensation) Storage Temperature Range -20 to 60?°C 90%RH or less (no condensation) External Dimensions 251 x 124 x 70 mm Weight Approx. 1000 g Conforming Standards Safety Softy EN61010-1, EMC EN 61326 Class B,EN 55011 Class B Group1, EN 61000-3-2, EN 61000-3-3, EN61326

  • Yokogawa CA150/SP1

    $1.333

    Multi-Functional Hand-Held Calibrator Designed for intuitively easy operation, individual functions are accessed directly by pressing assigned keys Within 0.02% of the DC voltage range for source and measure Receives current from the power supply up to 28VDC while transmitting milliampere DC signals to the loop Check the input and output signals of each device, while simultaneously checking the power supply Source and measurement can be performed simultaneously Large-screen display on an easy-to-hold vertical body Loop power supply function (24 VDC at a load of max 22 mA) It is possible to measure current in the mA range while supplying power

  • Yokogawa CA700

    $3.001

    Achieves the highest accuracy in the portable class Basic accuracy: ◦ Pressure (measurement) / 0.01% rdg. ◦ Current/voltage (source/measurement) / 0.015% rdg. > Rangeability Achieves the highest resolution and widest range in the portable class 0.001 kPa (200.000 kPa range) > User Support Strong support for field calibration and maintenance work Calibration procedures of pressure transmitters and pressure switches are embedded. As Found , As Left data and error rate (%) can be recorded. > Field Use IP54 dustproof and waterproof robust case enables use in harsh environments. > Accessories Three high-performance hand pump models for different pressure ranges are available. >

  • Yokogawa CA700

    $3.001

    Achieves the highest accuracy in the portable class Basic accuracy: ◦ Pressure (measurement) / 0.01% rdg. ◦ Current/voltage (source/measurement) / 0.015% rdg. > Rangeability Achieves the highest resolution and widest range in the portable class 0.001 kPa (200.000 kPa range) > User Support Strong support for field calibration and maintenance work Calibration procedures of pressure transmitters and pressure switches are embedded. As Found , As Left data and error rate (%) can be recorded. > Field Use IP54 dustproof and waterproof robust case enables use in harsh environments. > Accessories Three high-performance hand pump models for different pressure ranges are available. >

  • Yokogawa CA71/SP1

    $974

    Simultaneous signal generation and measurement capability: The CA71 lets you handle regular tests on TCs, RTDs and various other types of sensors and instruments, as well as operation checks when a problem has occurred (TC and RTD measurement functions are CA71 only.) Includes Options: Communications cable, data logging software, 120V power supply, Magnetic backing instrument case, source/measure cables, and NIST traceable certification Comprehensive source/measure instruments for all your calibration and equipment checking needs at maintenance sites Sensors and instruments require a wide variety of operation checks in the field Small, lightweight, multifunction calibrator that can simultaneously source and measure voltage, current, resistance, TC, RTD, frequency, and pulse signals Simultaneous signal generation and measurement capability: Lets you handle regular tests on TCs, RTDs and various other types of sensors and instruments, as well as operation checks when a problem has occurred AC voltage (including supply voltage) measurement capability: In cases where numerous signal converters and other devices are mounted on a rack or panel, the Handy Calibrator can be used to check the input and output signals of each device, while simultaneously checking the power supply Source: Values set in steps of 4-20 mA, 24V DC Power supply to transmitter Online communication: RS-232C-compliant optically isolated interface Divided output (n/m) function: Output settings are divided (n/m), eliminating the need for bothersome calculations for percentage output Auto step function: Changes the output value in step form based on the setting from the divided output (n/m) functions Changes can be generated automatically every 10% or 25% Sweep functions: Linearly raises or lowers the output The raising/lowering time can be set to either 16 or 32 seconds Memory function: Source values and measurements forming individual value sets can be saved to or loaded from the Handy Calibrators internal memory (maximum 50 value sets) Easy operation: The Handy Calibrator incorporates rotary switches for simple handing Just open the carrying case cover and connect the cables, and youre ready to take measurements > Each Unit Includes Source Signal Lead Cables (One Red, Two Black) 98020 Measurement Lead Cables (One Red, One Black) RD031 Carrying Case 93016 Terminal Adapter 99021 Users Manual Fuse: A1501EF (for current terminal input protection) Four AA Alkaline Batteries Communications Cable Data logging software Power Supply Magnetic backing instrument case Source/Measure Cables NIST Traceable Certification

  • Yokogawa CL130

    $77

    Yokogawa Model # CL130 Approved for comformity to safety standards EN61010-1,EN61010-2-031, EN61010-2-032 (CAT. III 600 V) Method of detection: Mean value Display: LCD (Digital display: 1999 counts) Response Time: Approx. 1 second (approx. 2 seconds on resistance renge) Range Switching: Manual-range Data Hold: On all range Ambient temperature and humidity: -10 to 50 °C (no condensation), up to 30 deg.C, 90% RH up to 40 deg.C, 75% RH, up to 50 deg.C, 45% RH Influence of external magnetic field: 2A or less at 400A/m Influence of conductor position: ±2% or less Circuit Voltage: 600Vrms or less Withstanding Voltage: 5.55kV AC for one minute Power Supply: 6F22(006P)9V ×1 or 6LR61 ×2 Battery Life: Approx. 200 hours (continuous) Consumed Current: Approx. 2mA Auto power-off: Approx. 10 minutes Diameter of measurable conductor: 30mm at maximum Dimensions: Approx. 93(W) × 210(H) × 40(D)mm Weight: Approx. 400g > Each Unit Includes Users manual (IM CL130) Batteries Carrying case (93032)

  • Yokogawa CL135

    $132

    Yokogawa Model # CL135 Approved for comformity to safety standard EN61010-1, EN61010-2-031, EN61010-2-032 (CAT. III 600 V) Method of detection: True RMS Display: LCD (Digital display: 1999 counts) Response Time: Approx. 1 second (approx. 2 seconds on resistance renge) Range Switching: Manual-range Data Hold: On all range Ambient temperature and humidity: -10 to 50 °C (no condensation), up to 30 deg.C, 90% RH up to 40 deg.C, 75% RH, up to 50 deg.C, 45% RH Influence of external magnetic field: 2A or less at 400A/m Influence of conductor position: ±2% or less Circuit Voltage: 600Vrms or less Withstanding Voltage: 5.55kV AC for one minute Power Supply: 6F22(006P)9V ×1 or 6LR61 ×2 Battery Life: Approx. 200 hours (continuous) Consumed Current: Approx. 2mA Auto power-off: Approx. 10 minutes Diameter of measurable conductor: 30mm at maximum Dimensions: Approx. 93(W) × 210(H) × 40(D)mm Weight: Approx. 400g > Each Unit Includes Users manual (IM CL130) Batteries Carrying case (93032)

  • Yokogawa CL150

    $117

    Yokogawa Model # CL150 Approved for comformity to safety standard EN61010-1, EN61010-2-031, EN61010-2-032 (CAT. III 600 V) Method of detection: Mean value Display: LCD (Digital display: 3999 counts) Response Time: Approx. 2 seconds Range Switching: Manual-range(on AC current range)/ Auto-range(on AC/DC voltage range, resistance range) Data Hold: On all range Peak Hold: On AC current range Ambient temperature and humidity: -40°C, 85% RH or less (no condensation) Influence of external magnetic field: 1A or less at 400A/m Influence of conductor position: ±(2.0% rdg 3dgt) or less Circuit Voltage: 1000Vrms or less Withstanding Voltage: 5.55kV AC for one minute Power Supply: R6P(SUM-3) ×2 or LR6 ×2 Battery Life: Approx. 150 hours (continuous) Consumed Current: Approx. 5mA Auto power-off: Approx. 10 minutes Diameter of measurable conductor: 54mm at maximum Dimensions: Approx. 105(W) × 247(H) × 49(D)mm Weight: Approx. 470g > Each Unit Includes Users manual (IM CL150) Batteries Carrying case (93034)

  • Yokogawa CL155

    $180

    CL100 series and 2343 series have basic function of AC current measurement. These clamps allow you to measure current range from 20mA to 1000A. Choose your desired diameter of measurable conductor from 24mm to 54mm. AC current measurement with current ranges up to 2000A True RMS display AC/DC voltage and resistance measurements 54mm in diameter of measurable conductor DC output function Data hold function Sleep function Approved for conformity to safety standards EN61010-1, EN61010-2-031, EN61010-2-032 (CAT III 600V)(CAT II 1000V) > Each Unit Includes Users manual Batteries Carrying Case (93034)