Showing 46–53 of 53 results
-
$4.519
Up to 380V test Voltage Designed with operator safety in mind: Set up the EUT to the right and behind the tester, and a right-handed operator will find himself standing to the left of the tester, allowing maximum separation Theoretical graphs and actual graphs showing the output of your tester are included with each MegaPulse Defib Surge P, allowing easy sanity checks and proof to visiting agency engineers of test setups Microcontroller technologies, front panel voltage meter indicates test peak open circuit voltage and polarity Reverse polarity waveforms available by pushing a button on the front panel. No need to change the test setup. Positive polarity indication minimizes errors Front panel voltage meter shows residual voltage in charging circuit for safer operation 1-year calibration cycle All test leads included 1 year warranty
-
$5.092
Compliance West USA MegaPulse DF-1A.2, Surge Tester DF-1 Fig. A.2 waveform with truncation, USB TestMinder Surge Tester and IGBT switch The DF-1P Isolation surge Tester is designed to generate the waveform described in AAMI DF-1, Figure A.2., for the Lead Connector electrical isolation test in AAMI DF-1, Annex A. The test can be set to automatically conduct the first 490 cycles (500 ± 50 as shown in Standard) of the test, and then stop testing to allow laboratory personnel monitor the last 10 cycles in accordance with the Standard. Voltage and current BNC outputs make waveform analysis convenient. Generates the waveform required for the Current carrying Test, AAMI DF-1, Appendix B, and described in AAMI DF-1, Figure B.2. Designed with operator safety in mind: Set up the EUT to the right and behind the tester, and a right-handed operator will find himself standing to the left of the tester, allowing maximum separation. Theoretical graphs and actual graphs showing the output of your tester are included with each MegaPulse DF-1P, allowing easy sanity checks and proof to visiting agency engineers of test setups. BNC Oscilloscope outputs allows quick connection and easy evaluation of voltage and current output waveforms. Reverse polarity waveforms available by pushing a button on the front panel. No need to change the test setup. Positive polarity indication minimizes errors. TestMinder computer control allows automation of the required 490 cycles, then the operator can conduct the last 10 cycles in which the current waveform must be monitored. (Waveform capture is not provided). 1-year calibration cycle. All test leads included. 1 year warranty Current Duration: 18 mS Meter accuracy: ±5 % Operation temperature: 15-40 °C Relativity humidity range: 0-90 % Non condensing Standards: AAMI DF-1 App B, Figure B.2 Storage: No Warranty: 1 Year Calibration: 1 year ECCN number: 3B992 HTS/Schedule B: 9030.39.0100 Product Dimensions: 17 w x 17 L x 6 H
-
$5.164
Generates the waveform required for the Current carrying Test, AAMI DF-1, Appendix B, and described in AAMI DF-1, Figure B.2. Designed with operator safety in mind: Set up the EUT to the right and behind the tester, and a right-handed operator will find himself standing to the left of the tester, allowing maximum separation. Theoretical graphs and actual graphs showing the output of your tester are included with each MegaPulse DF-1P, allowing easy sanity checks and proof to visiting agency engineers of test setups. BNC Oscilloscope outputs allows quick connection and easy evaluation of voltage and current output waveforms. Reverse polarity waveforms available by pushing a button on the front panel. No need to change the test setup. Positive polarity indication minimizes errors. TestMinder computer control allows automation of the required 490 cycles, then the operator can conduct the last 10 cycles in which the current waveform must be monitored. (Waveform capture is not provided). 1-year calibration cycle. All test leads included. 1 year warranty
-
$2.693
Generates the waveform required by AAMI DF 80 App. DD, Specifications for damped sinusoidal output waveforms. Designed with operator safety in mind: Set up the EUT to the right and behind the tester, and a right-handed operator will find himself standing to the left of the tester, allowing maximum separation. Theoretical graphs and actual graphs showing the output of your tester are included with each MegaPulse Defib Surge, allowing easy sanity checks and proof to visiting agency engineers of test setups. 360J output, 50 ohms impedance standard. Reverse polarity waveforms available by pushing a button on the front panel. No need to change the test setup. Positive polarity indication minimizes errors. Front panel voltage meter shows residual voltage in charging circuit for safer operation. 1-year calibration cycle. All test leads included. 1 year warranty
-
$5.197
Up to 380V test Voltage. Designed with operator safety in mind: Set up the EUT to the right and behind the tester, and a right-handed operator will find himself standing to the left of the tester, allowing maximum separation. Theoretical graphs and actual graphs showing the output of your tester are included with each MegaPulse Implantable Test 1, allowing historical documentation of original machine performance. Microcontroller technologies, front panel voltage meter indicates test peak open circuit voltage and polarity. Reverse polarity waveforms available by pushing a button on the front panel. No need to change the test setup. Positive polarity indication minimizes errors. 1-year calibration cycle. All resistor networks included internally. Test leads included. 1 year warranty
-
$4.779
Up to 270V test Voltage. Designed with operator safety in mind: Set up the EUT to the right and behind the tester, and a right-handed operator will find himself standing to the left of the tester, allowing maximum separation. Theoretical graphs and actual graphs showing the output of your tester are included with each MegaPulse Implantable Test 2, allowing historical documentation of original machine performance. Microcontroller technologies, front panel voltage meter indicates test peak open circuit voltage and polarity. Reverse polarity waveforms available by pushing a button on the front panel. No need to change the test setup. Positive polarity indication minimizes errors. 1-year calibration cycle. All resistor networks included internally. Test leads included. 1 year warranty
-
$4.048
MegaPulse Antenna Surge Tester PF 65, 10kV pulse derived from a 1nF capacitor, including the 4M ohm load resistor required by IEC 60065. Designed specifically for testing to IEC 60065 Fig. 7, IEC 60950 Annex N and IEC 62368-1 Annex D. The IEC 60065, Fig. 7a, switch S is our IER design, designed and built in compliance with IEC 60065, Fig. 7b. External interlock is supplied as standard equipment. Optional TestMinder PF computer control allows the 50 cycle test program to be conducted. Optional 1000:1 Oscilloscope output (reference only) The Antenna Surge PF generates the waveform required by IEC 60065, 60950 and 62368-1 to test antenna ports at 10kV output voltage. The MegaPulse Antenna Surge PF is configured with our IER relay and is built in a 19 by 6U enclosure. Theoretical graphs and actual graphs showing the output of your tester are included with each MegaPulse, allowing easy sanity checks and proof to visiting agency engineers of test setups. 1000:1 BNC Oscilloscope output option allows quick connections and easy evaluation of output waveforms. (Reference only). Requirements are for positive polarity tests only. No reverse polarity waveforms are available from the MegaPulse Antenna Surge PF. Front panel voltage meter shows residual voltage in charging circuit for safer operation.
-
$1.030
Option IER meets the requirements of IEC 65, Figure 7b