$1.872
Calibrates Hipot Testers, HV Power Supplies and Insulation Testers Basic Accuracy 0.03% DC and 0.1% True RMS AC Color Touch Screen Makes for Easy Measurement Selection and Display PC Connectivity with standard Ethernet, Serial, USB Printer Port and optional GPIB Chart Mode Stores 300 Readings to Document HV source drift, ramp time, overshoot and sag Dual inputs provide Differential or Phase to Phase Voltage Measurement High Speed DSP provides up to 60 filtered readings per second True RMS AC Measurement from 0.01Hz to 600Hz Covering VLF to Aviation Frequencies AC Noise Rejection 78dB For Rock Solid, 6 Digit DC Measurements Optional Lithium-ion Battery Pack goes up to 11 hours between charges CE mark Certified to EN61010 Three Year Extended Warranty > Each Unit Includes NIST traceable certificate of calibration with data Direct input test leads Chassis ground lead External power supply
-
$2.492
Product Highlihgts Highest Level of Operator Safety – features include: GFI High speed shut down for earth ground leakage faults, SFI™ Safety Fault Interlock – High speed shut down output for interruption of safety interlock, TLSS™ Test Lead Safety Sense – Clamps DUT chassis near ground by continuously verifying proper connection of test leads prior to and during HV testing, Recessed start switch prevents inadvertent actuation High Power Output – means better drive capability and increased test throughout. With up to 50mA of sourcing current for DC hipot the 95X Series gets heavy duty jobs done fast – available 100mA & 200mA AC drive tackles even the toughest sourcing requirements Wide Range of built-in Voltage Capabilities – Choose from 6.5KVDC, 11KVDC or 15KVDC and 6KVAC, 10KVAC or up to 30KV RMS AC with external option The Fastest Hipot Testers available – Thanks to our Dual Coldfire® microprocessors combined with Dual DSPs to provide Ramp rates up to 50KV/second, dwell times as low as 20mS and overall test times as fast as 3mS in optional Flash mode Expansive Test Sequence Memory holds up to 100 tests with up to 100 steps per test. Tests can be selected via front panel, Ethernet, RS232, Digital I/O or with optional GPIB Ground Bond Test Capability available in three models with output currents from 100mA to 40Amps RMS and test times from 20mS to 1000 seconds or longer 4-Wire Milli-Ohmmeter Function provides fast, accurate 5 digit resistance measurements with resolution down to 100µΩ and range up to 100K ohms Built-in Phase Angle Measurement – allows the measurement and display of both resistive (in-phase) leakage current and reactive (out-of-phase) leakage current caused by capacitive coupling Multi-Dwell Functionality – permits dwells at different voltage levels without having to return to zero between test steps – dramatically simplifying advanced analysis of dielectric properties Ramp High/Dwell Low Current Limits – permits the user to set separate limits for the ramp and dwell providing faster ramp times and lower leakage test limits Ethernet, RS232, Digital I/O, USB Printer & Scanner Control – All Standard Interfaces – Provides the highest level of test automation. GPIB optional High Voltage Scanner Control – up to 256 point switching capability with available 964i HV Scanners. Route voltages up to 15KV and currents up to 40A for multi-point hipot and ground bond tests Dual Dimensional / Test Specific / Broadband Arc Detection. Where lesser testers allow you to set a single, global, amplitude only arc limit – the technologically advanced 95X Series utilizes time & amplitude based arc limits and uniquely applies them to each desired test Pico-Amp Leakage Measurement insures that even the lowest leakage current levels are accurately detected and tera-ohm range IR readings are stable and precise Test Specific Fixture & Cable Compensation – Automatically calibrate out offset errors caused by lead resistance, fixture capacitance and leakage Multi-Mode IR – Insulation Resistance values up to one Tera-ohm can be obtained with precision in your choice of 3 IR test modes – end on time, end on pass or end on fail Continuously Variable IR Test Voltage – Unlike most IR testers which limit you to 3 or 4 discrete test voltages, the 950i Series allows you to select the test voltage you need. Starting as low as 20V all the way to 6.5KV, 11KV or 15KVDC Capacitance Test Modes – For AC & DC hipot and IR provide tightly controlled charge and discharge profiles for superior results on critical solar panel tests and other highly capacitive loads Light Weight Switching Power Supply Design – Better reliability, easier on your back. Compare the 8.2 kg 95X to whatever youve been using 400Hz AC Voltage Withstand Testing provides aviation frequency specific test results for a more effective analysis of dielectric properties on avionic components Solar Panel Testing Simplified – Designed with PV testing in mind, the 950i Series uses pico-amp resolution to detect minute defects in solar cells 3 Year Extended Warranty – 1 year standard, total of 3 years extended warranty with registration and annual factory calibration. Built-in reliability you can count on for years to come Safety Tested per EN 61010-1. EMC compliant to EN 61326-1 > Each Unit Includes Alligator test leads NIST traceable calibration certificate with no data power cord and operators manual
-
$2.847
Product Highlihgts Highest Level of Operator Safety – features include: GFI High speed shut down for earth ground leakage faults, SFI™ Safety Fault Interlock – High speed shut down output for interruption of safety interlock, TLSS™ Test Lead Safety Sense – Clamps DUT chassis near ground by continuously verifying proper connection of test leads prior to and during HV testing, Recessed start switch prevents inadvertent actuation High Power Output – means better drive capability and increased test throughout. With up to 50mA of sourcing current for DC hipot the 95X Series gets heavy duty jobs done fast – available 100mA & 200mA AC drive tackles even the toughest sourcing requirements Wide Range of built-in Voltage Capabilities – Choose from 6.5KVDC, 11KVDC or 15KVDC and 6KVAC, 10KVAC or up to 30KV RMS AC with external option The Fastest Hipot Testers available – Thanks to our Dual Coldfire® microprocessors combined with Dual DSPs to provide Ramp rates up to 50KV/second, dwell times as low as 20mS and overall test times as fast as 3mS in optional Flash mode Expansive Test Sequence Memory holds up to 100 tests with up to 100 steps per test. Tests can be selected via front panel, Ethernet, RS232, Digital I/O or with optional GPIB Ground Bond Test Capability available in three models with output currents from 100mA to 40Amps RMS and test times from 20mS to 1000 seconds or longer 4-Wire Milli-Ohmmeter Function provides fast, accurate 5 digit resistance measurements with resolution down to 100µΩ and range up to 100K ohms Built-in Phase Angle Measurement – allows the measurement and display of both resistive (in-phase) leakage current and reactive (out-of-phase) leakage current caused by capacitive coupling Multi-Dwell Functionality – permits dwells at different voltage levels without having to return to zero between test steps – dramatically simplifying advanced analysis of dielectric properties Ramp High/Dwell Low Current Limits – permits the user to set separate limits for the ramp and dwell providing faster ramp times and lower leakage test limits Ethernet, RS232, Digital I/O, USB Printer & Scanner Control – All Standard Interfaces – Provides the highest level of test automation. GPIB optional High Voltage Scanner Control – up to 256 point switching capability with available 964i HV Scanners. Route voltages up to 15KV and currents up to 40A for multi-point hipot and ground bond tests Dual Dimensional / Test Specific / Broadband Arc Detection. Where lesser testers allow you to set a single, global, amplitude only arc limit – the technologically advanced 95X Series utilizes time & amplitude based arc limits and uniquely applies them to each desired test Pico-Amp Leakage Measurement insures that even the lowest leakage current levels are accurately detected and tera-ohm range IR readings are stable and precise Test Specific Fixture & Cable Compensation – Automatically calibrate out offset errors caused by lead resistance, fixture capacitance and leakage Multi-Mode IR – Insulation Resistance values up to one Tera-ohm can be obtained with precision in your choice of 3 IR test modes – end on time, end on pass or end on fail Continuously Variable IR Test Voltage – Unlike most IR testers which limit you to 3 or 4 discrete test voltages, the 950i Series allows you to select the test voltage you need. Starting as low as 20V all the way to 6.5KV, 11KV or 15KVDC Capacitance Test Modes – For AC & DC hipot and IR provide tightly controlled charge and discharge profiles for superior results on critical solar panel tests and other highly capacitive loads Light Weight Switching Power Supply Design – Better reliability, easier on your back. Compare the 8.2 kg 95X to whatever youve been using 400Hz AC Voltage Withstand Testing provides aviation frequency specific test results for a more effective analysis of dielectric properties on avionic components Solar Panel Testing Simplified – Designed with PV testing in mind, the 950i Series uses pico-amp resolution to detect minute defects in solar cells 3 Year Extended Warranty – 1 year standard, total of 3 years extended warranty with registration and annual factory calibration. Built-in reliability you can count on for years to come Safety Tested per EN 61010-1. EMC compliant to EN 61326-1 > Each Unit Includes Alligator test leads NIST traceable calibration certificate with no data power cord and operators manual
-
$2.958
Product Highlihgts Highest Level of Operator Safety – features include: GFI High speed shut down for earth ground leakage faults, SFI™ Safety Fault Interlock – High speed shut down output for interruption of safety interlock, TLSS™ Test Lead Safety Sense – Clamps DUT chassis near ground by continuously verifying proper connection of test leads prior to and during HV testing, Recessed start switch prevents inadvertent actuation High Power Output – means better drive capability and increased test throughout. With up to 50mA of sourcing current for DC hipot the 95X Series gets heavy duty jobs done fast – available 100mA & 200mA AC drive tackles even the toughest sourcing requirements Wide Range of built-in Voltage Capabilities – Choose from 6.5KVDC, 11KVDC or 15KVDC and 6KVAC, 10KVAC or up to 30KV RMS AC with external option The Fastest Hipot Testers available – Thanks to our Dual Coldfire® microprocessors combined with Dual DSPs to provide Ramp rates up to 50KV/second, dwell times as low as 20mS and overall test times as fast as 3mS in optional Flash mode Expansive Test Sequence Memory holds up to 100 tests with up to 100 steps per test. Tests can be selected via front panel, Ethernet, RS232, Digital I/O or with optional GPIB Ground Bond Test Capability available in three models with output currents from 100mA to 40Amps RMS and test times from 20mS to 1000 seconds or longer 4-Wire Milli-Ohmmeter Function provides fast, accurate 5 digit resistance measurements with resolution down to 100µΩ and range up to 100K ohms Built-in Phase Angle Measurement – allows the measurement and display of both resistive (in-phase) leakage current and reactive (out-of-phase) leakage current caused by capacitive coupling Multi-Dwell Functionality – permits dwells at different voltage levels without having to return to zero between test steps – dramatically simplifying advanced analysis of dielectric properties Ramp High/Dwell Low Current Limits – permits the user to set separate limits for the ramp and dwell providing faster ramp times and lower leakage test limits Ethernet, RS232, Digital I/O, USB Printer & Scanner Control – All Standard Interfaces – Provides the highest level of test automation. GPIB optional High Voltage Scanner Control – up to 256 point switching capability with available 964i HV Scanners. Route voltages up to 15KV and currents up to 40A for multi-point hipot and ground bond tests Dual Dimensional / Test Specific / Broadband Arc Detection. Where lesser testers allow you to set a single, global, amplitude only arc limit – the technologically advanced 95X Series utilizes time & amplitude based arc limits and uniquely applies them to each desired test Pico-Amp Leakage Measurement insures that even the lowest leakage current levels are accurately detected and tera-ohm range IR readings are stable and precise Test Specific Fixture & Cable Compensation – Automatically calibrate out offset errors caused by lead resistance, fixture capacitance and leakage Multi-Mode IR – Insulation Resistance values up to one Tera-ohm can be obtained with precision in your choice of 3 IR test modes – end on time, end on pass or end on fail Continuously Variable IR Test Voltage – Unlike most IR testers which limit you to 3 or 4 discrete test voltages, the 950i Series allows you to select the test voltage you need. Starting as low as 20V all the way to 6.5KV, 11KV or 15KVDC Capacitance Test Modes – For AC & DC hipot and IR provide tightly controlled charge and discharge profiles for superior results on critical solar panel tests and other highly capacitive loads Light Weight Switching Power Supply Design – Better reliability, easier on your back. Compare the 8.2 kg 95X to whatever youve been using 400Hz AC Voltage Withstand Testing provides aviation frequency specific test results for a more effective analysis of dielectric properties on avionic components Solar Panel Testing Simplified – Designed with PV testing in mind, the 950i Series uses pico-amp resolution to detect minute defects in solar cells 3 Year Extended Warranty – 1 year standard, total of 3 years extended warranty with registration and annual factory calibration. Built-in reliability you can count on for years to come Safety Tested per EN 61010-1. EMC compliant to EN 61326-1 > Each Unit Includes Alligator test leads NIST traceable calibration certificate with no data power cord and operators manual
-
$3.394
Product Highlihgts Highest Level of Operator Safety – features include: GFI High speed shut down for earth ground leakage faults, SFI™ Safety Fault Interlock – High speed shut down output for interruption of safety interlock, TLSS™ Test Lead Safety Sense – Clamps DUT chassis near ground by continuously verifying proper connection of test leads prior to and during HV testing, Recessed start switch prevents inadvertent actuation High Power Output – means better drive capability and increased test throughout. With up to 50mA of sourcing current for DC hipot the 95X Series gets heavy duty jobs done fast – available 100mA & 200mA AC drive tackles even the toughest sourcing requirements Wide Range of built-in Voltage Capabilities – Choose from 6.5KVDC, 11KVDC or 15KVDC and 6KVAC, 10KVAC or up to 30KV RMS AC with external option The Fastest Hipot Testers available – Thanks to our Dual Coldfire® microprocessors combined with Dual DSPs to provide Ramp rates up to 50KV/second, dwell times as low as 20mS and overall test times as fast as 3mS in optional Flash mode Expansive Test Sequence Memory holds up to 100 tests with up to 100 steps per test. Tests can be selected via front panel, Ethernet, RS232, Digital I/O or with optional GPIB Ground Bond Test Capability available in three models with output currents from 100mA to 40Amps RMS and test times from 20mS to 1000 seconds or longer 4-Wire Milli-Ohmmeter Function provides fast, accurate 5 digit resistance measurements with resolution down to 100µΩ and range up to 100K ohms Built-in Phase Angle Measurement – allows the measurement and display of both resistive (in-phase) leakage current and reactive (out-of-phase) leakage current caused by capacitive coupling Multi-Dwell Functionality – permits dwells at different voltage levels without having to return to zero between test steps – dramatically simplifying advanced analysis of dielectric properties Ramp High/Dwell Low Current Limits – permits the user to set separate limits for the ramp and dwell providing faster ramp times and lower leakage test limits Ethernet, RS232, Digital I/O, USB Printer & Scanner Control – All Standard Interfaces – Provides the highest level of test automation. GPIB optional High Voltage Scanner Control – up to 256 point switching capability with available 964i HV Scanners. Route voltages up to 15KV and currents up to 40A for multi-point hipot and ground bond tests Dual Dimensional / Test Specific / Broadband Arc Detection. Where lesser testers allow you to set a single, global, amplitude only arc limit – the technologically advanced 95X Series utilizes time & amplitude based arc limits and uniquely applies them to each desired test Pico-Amp Leakage Measurement insures that even the lowest leakage current levels are accurately detected and tera-ohm range IR readings are stable and precise Test Specific Fixture & Cable Compensation – Automatically calibrate out offset errors caused by lead resistance, fixture capacitance and leakage Multi-Mode IR – Insulation Resistance values up to one Tera-ohm can be obtained with precision in your choice of 3 IR test modes – end on time, end on pass or end on fail Continuously Variable IR Test Voltage – Unlike most IR testers which limit you to 3 or 4 discrete test voltages, the 950i Series allows you to select the test voltage you need. Starting as low as 20V all the way to 6.5KV, 11KV or 15KVDC Capacitance Test Modes – For AC & DC hipot and IR provide tightly controlled charge and discharge profiles for superior results on critical solar panel tests and other highly capacitive loads Light Weight Switching Power Supply Design – Better reliability, easier on your back. Compare the 8.2 kg 95X to whatever youve been using 400Hz AC Voltage Withstand Testing provides aviation frequency specific test results for a more effective analysis of dielectric properties on avionic components Solar Panel Testing Simplified – Designed with PV testing in mind, the 950i Series uses pico-amp resolution to detect minute defects in solar cells 3 Year Extended Warranty – 1 year standard, total of 3 years extended warranty with registration and annual factory calibration. Built-in reliability you can count on for years to come Safety Tested per EN 61010-1. EMC compliant to EN 61326-1 > Each Unit Includes Alligator test leads NIST traceable calibration certificate with no data power cord and operators manual
-
$3.394
Product Highlihgts Highest Level of Operator Safety – features include: GFI High speed shut down for earth ground leakage faults, SFI™ Safety Fault Interlock – High speed shut down output for interruption of safety interlock, TLSS™ Test Lead Safety Sense – Clamps DUT chassis near ground by continuously verifying proper connection of test leads prior to and during HV testing, Recessed start switch prevents inadvertent actuation High Power Output – means better drive capability and increased test throughout. With up to 50mA of sourcing current for DC hipot the 95X Series gets heavy duty jobs done fast – available 100mA & 200mA AC drive tackles even the toughest sourcing requirements Wide Range of built-in Voltage Capabilities – Choose from 6.5KVDC, 11KVDC or 15KVDC and 6KVAC, 10KVAC or up to 30KV RMS AC with external option The Fastest Hipot Testers available – Thanks to our Dual Coldfire® microprocessors combined with Dual DSPs to provide Ramp rates up to 50KV/second, dwell times as low as 20mS and overall test times as fast as 3mS in optional Flash mode Expansive Test Sequence Memory holds up to 100 tests with up to 100 steps per test. Tests can be selected via front panel, Ethernet, RS232, Digital I/O or with optional GPIB Ground Bond Test Capability available in three models with output currents from 100mA to 40Amps RMS and test times from 20mS to 1000 seconds or longer 4-Wire Milli-Ohmmeter Function provides fast, accurate 5 digit resistance measurements with resolution down to 100µΩ and range up to 100K ohms Built-in Phase Angle Measurement – allows the measurement and display of both resistive (in-phase) leakage current and reactive (out-of-phase) leakage current caused by capacitive coupling Multi-Dwell Functionality – permits dwells at different voltage levels without having to return to zero between test steps – dramatically simplifying advanced analysis of dielectric properties Ramp High/Dwell Low Current Limits – permits the user to set separate limits for the ramp and dwell providing faster ramp times and lower leakage test limits Ethernet, RS232, Digital I/O, USB Printer & Scanner Control – All Standard Interfaces – Provides the highest level of test automation. GPIB optional High Voltage Scanner Control – up to 256 point switching capability with available 964i HV Scanners. Route voltages up to 15KV and currents up to 40A for multi-point hipot and ground bond tests Dual Dimensional / Test Specific / Broadband Arc Detection. Where lesser testers allow you to set a single, global, amplitude only arc limit – the technologically advanced 95X Series utilizes time & amplitude based arc limits and uniquely applies them to each desired test Pico-Amp Leakage Measurement insures that even the lowest leakage current levels are accurately detected and tera-ohm range IR readings are stable and precise Test Specific Fixture & Cable Compensation – Automatically calibrate out offset errors caused by lead resistance, fixture capacitance and leakage Multi-Mode IR – Insulation Resistance values up to one Tera-ohm can be obtained with precision in your choice of 3 IR test modes – end on time, end on pass or end on fail Continuously Variable IR Test Voltage – Unlike most IR testers which limit you to 3 or 4 discrete test voltages, the 950i Series allows you to select the test voltage you need. Starting as low as 20V all the way to 6.5KV, 11KV or 15KVDC Capacitance Test Modes – For AC & DC hipot and IR provide tightly controlled charge and discharge profiles for superior results on critical solar panel tests and other highly capacitive loads Light Weight Switching Power Supply Design – Better reliability, easier on your back. Compare the 8.2 kg 95X to whatever youve been using 400Hz AC Voltage Withstand Testing provides aviation frequency specific test results for a more effective analysis of dielectric properties on avionic components Solar Panel Testing Simplified – Designed with PV testing in mind, the 950i Series uses pico-amp resolution to detect minute defects in solar cells 3 Year Extended Warranty – 1 year standard, total of 3 years extended warranty with registration and annual factory calibration. Built-in reliability you can count on for years to come Safety Tested per EN 61010-1. EMC compliant to EN 61326-1 > Each Unit Includes Alligator test leads NIST traceable calibration certificate with no data power cord and operators manual
-
$3.394
Product Highlihgts Highest Level of Operator Safety – features include: GFI High speed shut down for earth ground leakage faults, SFI™ Safety Fault Interlock – High speed shut down output for interruption of safety interlock, TLSS™ Test Lead Safety Sense – Clamps DUT chassis near ground by continuously verifying proper connection of test leads prior to and during HV testing, Recessed start switch prevents inadvertent actuation High Power Output – means better drive capability and increased test throughout. With up to 50mA of sourcing current for DC hipot the 95X Series gets heavy duty jobs done fast – available 100mA & 200mA AC drive tackles even the toughest sourcing requirements Wide Range of built-in Voltage Capabilities – Choose from 6.5KVDC, 11KVDC or 15KVDC and 6KVAC, 10KVAC or up to 30KV RMS AC with external option The Fastest Hipot Testers available – Thanks to our Dual Coldfire® microprocessors combined with Dual DSPs to provide Ramp rates up to 50KV/second, dwell times as low as 20mS and overall test times as fast as 3mS in optional Flash mode Expansive Test Sequence Memory holds up to 100 tests with up to 100 steps per test. Tests can be selected via front panel, Ethernet, RS232, Digital I/O or with optional GPIB Ground Bond Test Capability available in three models with output currents from 100mA to 40Amps RMS and test times from 20mS to 1000 seconds or longer 4-Wire Milli-Ohmmeter Function provides fast, accurate 5 digit resistance measurements with resolution down to 100µΩ and range up to 100K ohms Built-in Phase Angle Measurement – allows the measurement and display of both resistive (in-phase) leakage current and reactive (out-of-phase) leakage current caused by capacitive coupling Multi-Dwell Functionality – permits dwells at different voltage levels without having to return to zero between test steps – dramatically simplifying advanced analysis of dielectric properties Ramp High/Dwell Low Current Limits – permits the user to set separate limits for the ramp and dwell providing faster ramp times and lower leakage test limits Ethernet, RS232, Digital I/O, USB Printer & Scanner Control – All Standard Interfaces – Provides the highest level of test automation. GPIB optional High Voltage Scanner Control – up to 256 point switching capability with available 964i HV Scanners. Route voltages up to 15KV and currents up to 40A for multi-point hipot and ground bond tests Dual Dimensional / Test Specific / Broadband Arc Detection. Where lesser testers allow you to set a single, global, amplitude only arc limit – the technologically advanced 95X Series utilizes time & amplitude based arc limits and uniquely applies them to each desired test Pico-Amp Leakage Measurement insures that even the lowest leakage current levels are accurately detected and tera-ohm range IR readings are stable and precise Test Specific Fixture & Cable Compensation – Automatically calibrate out offset errors caused by lead resistance, fixture capacitance and leakage Multi-Mode IR – Insulation Resistance values up to one Tera-ohm can be obtained with precision in your choice of 3 IR test modes – end on time, end on pass or end on fail Continuously Variable IR Test Voltage – Unlike most IR testers which limit you to 3 or 4 discrete test voltages, the 950i Series allows you to select the test voltage you need. Starting as low as 20V all the way to 6.5KV, 11KV or 15KVDC Capacitance Test Modes – For AC & DC hipot and IR provide tightly controlled charge and discharge profiles for superior results on critical solar panel tests and other highly capacitive loads Light Weight Switching Power Supply Design – Better reliability, easier on your back. Compare the 8.2 kg 95X to whatever youve been using 400Hz AC Voltage Withstand Testing provides aviation frequency specific test results for a more effective analysis of dielectric properties on avionic components Solar Panel Testing Simplified – Designed with PV testing in mind, the 950i Series uses pico-amp resolution to detect minute defects in solar cells 3 Year Extended Warranty – 1 year standard, total of 3 years extended warranty with registration and annual factory calibration. Built-in reliability you can count on for years to come Safety Tested per EN 61010-1. EMC compliant to EN 61326-1 > Each Unit Includes Alligator test leads NIST traceable calibration certificate with no data power cord and operators manual
-
$1.197
High Voltage Ratings to 3KV, 7KV, 10KV or 15KV High Current Ratings to 40 Amps Reduces hazardous operator exposure to high voltage Improves test quality, consistency and repeatability Enhances end product quality and reliability Up to 64 channels in a single compact unit Vitrek Hipot Tester control ports and RS232 interfaces standard GPIB optionally available May be controlled directly by Vitrek Hipot Tester Available QuickTest™ graphical software with full data aquisition CE mark certified to EN 61010 Made in the U.S.A.
-
$2.907
Highest Range of IR Test Voltage Choose from 6.5KVDC or 11KVDC maximum output High speed output control with Dual Coldfire microprocessors and Dual DSPs to provide dwell times as low as 100ms High Resistance Measurement Range — Transfer measurement up to 150 Teraohms Expansive Test Sequency Memory holds up to 100 tests with up to 254 steps per test. Tests can be selected via front panel, Ethernet, RS232 or with optional GPIB. Multi-Dwell Functionality — permits dwells at different voltage levels without having to return to zero between test steps – dramatically simplifying advanced analysis of dielectric properties Ethernet, RS232, Digital I/O & Scanner Control — All standard interfaces – Provides the highest level of test automation. GPIB available Safety Tested per EN 61010-1. EMC compliant to EN 61326-1 > Each Unit Includes TL-980 Test Lead Set NIST traceable Calibration Certificate