Showing all 2 results

  • United Instruments LPC-10

    $3.890

    United Instruments Model # LPC-10 Measurement Range: -1.5 to 11.5 H2O (-3.75 to 27.5 mbar) Measurement Accuracy: ± 0.035% of Full Scale @ 25ºC (Includes zero, span, hysteresis and repeatability errors) Repeatability/Hysteresis: ± 0.015% Typical Calibration Point Certainty: ± 0.012% Typical Between Point Linearity: ± 0.01% Typical Maximum Overpressure: 5 PSI (347 mbar) Control Range: -10 to 10 H2O Standard (-25 mbar to 25 mbar) System Accuracy: Lab Environment (@ 25ºC) ± 0.035% of Full Scale (Combined Measure/Control) Field Operation (10 to 30ºC) ± 0.05% of Full Scale Stability: ± 0.05% of Full Scale/Year Temperature Range: Operational: 0ºC to 50ºC, Calibrated: 10ºC to 30ºC, Storage: -20ºC to 50ºC Input Power Requirements: 105-135 VAC/210-270 VAC—50/60 Hz @ 48 VA Battery Operation: 2.2 AHr Self-Contained NiCad Operational (50% duty): Approximately 2 Hours Display: 2 x 20 Alphanumeric Fluorescent Display: 0.2 ( 5mm) H Units: in H2O @ 20ºC, in H2O @ 4ºC, mm H2O @ 20ºC, in H2O @ 4ºC, cm H2O @ 20ºC, cm H2O @ 4ºC, in Hg @ 0ºC, Torr (mm Hg), cm Hg @ 0ºC, mBar Pascal, kPascal, PSI Indicators: Measure, Control, Program, Power, Standby, Battery Digital Interface: Via RS232, 4800 Baud Sensor Technology: Solid State, Piezoresistive Strain Gauge Pressure Synthesis: Via Balanced Differential Piston Array, Servo Actuated Closed Loop Digitally Governed Control Certainty: ± 0, -.015% Auto Zero Certainty: Microprocessor Governed Via Electropneumatic Control (Resident in RAM) Better Than ± 0.005% of Full Scale Calibration: Factory Calibrated Against NIST Traceable Standard Dimensions & Weight: 10 Wide x 4.25 High x 8.25 Deep) Warranty: 1 Year Parts & Labor (90 days for NiCad batteries) > Each Unit Includes Manual Line Cord RS232 Cable Manufacturers NIST Traceable Cert United Instruments Model # LPC-10 Measurement Range: -1.5 to 11.5 H2O (-3.75 to 27.5 mbar) Measurement Accuracy: ± 0.035% of Full Scale @ 25ºC (Includes zero, span, hysteresis and repeatability errors) Repeatability/Hysteresis: ± 0.015% Typical Calibration Point Certainty: ± 0.012% Typical Between Point Linearity: ± 0.01% Typical Maximum Overpressure: 5 PSI (347 mbar) Control Range: -10 to 10 H2O Standard (-25 mbar to 25 mbar) System Accuracy: Lab Environment (@ 25ºC) ± 0.035% of Full Scale (Combined Measure/Control) Field Operation (10 to 30ºC) ± 0.05% of Full Scale Stability: ± 0.05% of Full Scale/Year Temperature Range: Operational: 0ºC to 50ºC, Calibrated: 10ºC to 30ºC, Storage: -20ºC to 50ºC Input Power Requirements: 105-135 VAC/210-270 VAC—50/60 Hz @ 48 VA Battery Operation: 2.2 AHr Self-Contained NiCad Operational (50% duty): Approximately 2 Hours Display: 2 x 20 Alphanumeric Fluorescent Display: 0.2 ( 5mm) H Units: in H2O @ 20ºC, in H2O @ 4ºC, mm H2O @ 20ºC, in H2O @ 4ºC, cm H2O @ 20ºC, cm H2O @ 4ºC, in Hg @ 0ºC, Torr (mm Hg), cm Hg @ 0ºC, mBar Pascal, kPascal, PSI Indicators: Measure, Control, Program, Power, Standby, Battery Digital Interface: Via RS232, 4800 Baud Sensor Technology: Solid State, Piezoresistive Strain Gauge Pressure Synthesis: Via Balanced Differential Piston Array, Servo Actuated Closed Loop Digitally Governed Control Certainty: ± 0, -.015% Auto Zero Certainty: Microprocessor Governed Via Electropneumatic Control (Resident in RAM) Better Than ± 0.005% of Full Scale Calibration: Factory Calibrated Against NIST Traceable Standard Dimensions & Weight: 10 Wide x 4.25 High x 8.25 Deep) Warranty: 1 Year Parts & Labor (90 days for NiCad batteries) > Each Unit Includes Manual Line Cord RS232 Cable Manufacturers NIST Traceable Cert >

  • United Instruments LPC-30

    $3.334

    United Instruments Model # LPC-30 Measurement Range: -1.5 to 11.5 H2O (-3.75 to 27.5 mbar) Measurement Accuracy: ± 0.035% of Full Scale @ 25ºC (Includes zero, span, hysteresis and repeatability errors) Repeatability/Hysteresis: ± 0.015% Typical Calibration Point Certainty: ± 0.012% Typical Between Point Linearity: ± 0.01% Typical Maximum Overpressure: 5 PSI (347 mbar) Control Range: -10 to 10 H2O Standard (-25 mbar to 25 mbar) System Accuracy: Lab Environment (@ 25ºC) ± 0.035% of Full Scale (Combined Measure/Control) Field Operation (10 to 30ºC) ± 0.05% of Full Scale Stability: ± 0.05% of Full Scale/Year Temperature Range: Operational: 0ºC to 50ºC, Calibrated: 10ºC to 30ºC, Storage: -20ºC to 50ºC Input Power Requirements: 105-135 VAC/210-270 VAC—50/60 Hz @ 48 VA Battery Operation: 2.2 AHr Self-Contained NiCad Operational (50% duty): Approximately 2 Hours Display: 2 x 20 Alphanumeric Fluorescent Display: 0.2 ( 5mm) H Units: in H2O @ 20ºC, in H2O @ 4ºC, mm H2O @ 20ºC, in H2O @ 4ºC, cm H2O @ 20ºC, cm H2O @ 4ºC, in Hg @ 0ºC, Torr (mm Hg), cm Hg @ 0ºC, mBar Pascal, kPascal, PSI Indicators: Measure, Control, Program, Power, Standby, Battery Digital Interface: Via RS232, 4800 Baud Sensor Technology: Solid State, Piezoresistive Strain Gauge Pressure Synthesis: Via Balanced Differential Piston Array, Servo Actuated Closed Loop Digitally Governed Control Certainty: ± 0, -.015% Auto Zero Certainty: Microprocessor Governed Via Electropneumatic Control (Resident in RAM) Better Than ± 0.005% of Full Scale Calibration: Factory Calibrated Against NIST Traceable Standard Dimensions & Weight: 10 Wide x 4.25 High x 8.25 Deep) Warranty: 1 Year Parts & Labor (90 days for NiCad batteries) > Each Unit Includes Manual Line Cord RS232 Cable Manufacturers NIST Traceable Cert