-
$2.436
4.3 TFT color touchscreen display Power cord (included) RS232 with GLP/GMP data output, USB Host and USB Device (included) Metal base, ABS top housing, halogen heat source, stainless steel pan support, stainless steel pan handler, in-use cover Seven shut-off criteria (manual, timed, autofree %/s, autofree mg/s, A30, A60 and A90), four drying profiles (standard, fast, ramp and step), storage up to 100 methods and 1000 test results for all methods, user guide, 40°C to 230°C heating temperature range (1°C increments), 13 operational languages Maximum Capacity 120 g Readability Moisture Content 1 mg/0.01% Pan Size 3.5 in (90 mm) Heater Type Halogen Lamp Communication USB host x 2, USB device, RS232 Display Full-Color 4.3 in Touchscreen WQVGA Heating Profiles Standard, Ramp, Step, Fast In-use cover Included Moisture Range 0 % â 100 % Net Weight 11.53 lb (5.23 kg) Operating Range (Temp.) 10 °C â 40 °C Power 115 v, 60 Hz Sample Size 0.5 g â 120 g Shut-Off Criteria Manual, Timed, Automatic Preset Weight Loss/Time, Custom User Set Weight Loss/Time, Custom-User Set Moisture% Loss/Time Temperature Range 40 °C â 230 °C Test Library 100 Units of Measurement Gram, %MC, %RG, Ü Working Environment 50°F â 104°F, 85%RH, non-condensing (10°C â 40°C, 85%RH, non-condensing)
-
$1.881
Maximum Capacity 90 g Readability Moisture Content 1 mg/0.01% Pan Size 90 mm Heater Type Halogen Lamp Communication USB host x 2, USB device, RS232 Dimensions (HxLxW) 7.09 in x 13.98 in x 8.31 in (180 mm x 355 mm x 211 mm) Display Full-Color 4.3 in Touchscreen WQVGA In-use cover Included Power 115 v, 60 Hz Shut-Off Criteria Manual, Timed, Auto Tare Range 0gâ225g Temperature Range 40 °C â 200 °C Units of Measurement Gram, %MC, %RG, Ü Working Environment 50°F â 104°F, 85%RH, non-condensing (10°C â 40°C, 85%RH, non-condensing)
-
$247
Measurement Range 00.0 μS/cm – 199.9 mS/cm,0.1 mg/L – 199.9 g/L (TDS),0 – 100 °C Measurement Resolution 0.01 μS/cm,0.1 mg/L,0.1 °C Display LCD Electrode STCON3 (Included) Accuracy ± (Temperature) 0.3 °C Battery Life 250 Hours with Disposable Batteries Calibration 1 Point Conductivity accuracy 0.5 % Conductivity measuring range 0.01 μS/cm-199.9 mS/cm Dimensions (HxLxW) 1.38 in x 6.69 in x 3.54 in (33 mm x 170 mm x 90 mm) In-use cover No Measurement Range (Temperature) 0 °C – 100 °C Net Weight 0.16 kg Parameter Conductivity / TDS Power 4 AAA (LR03) Batteries (Included) Resolution Cond. (Variable) 0.01 – 1 Temperature Compensation Automatic Temperature resolution 0.1 °C Temperature Sensor 30 KΩ NTC Working Environment 41°F – 104°F, 80%RH, non-condensing (5°C – 40°C, 80%RH, non-condensing)