Showing 55–63 of 66 results
-
$1.231
The CPG2300 Portable Pressure Calibrator is used in diverse applications from rugged field calibration of pressure transmitters used in gas transmission, to testing and calibration of transducers in clean rooms and nuclear power plants. Wherever there is a need for a high level of accuracy in a portable pressure calibrator device. The CPG2300 Portable Pressure Calibrator has one of the best uncertainty specifications of any portable pressure calibration instrument. With an uncertainty of 0.015% FS, technicians are able to achieve the test uncertainty ratios required for modern transmitters. Temperature compensation from 0 to 50oC, permits use in most environments, without degradation of accuracy. Seventeen selectable pressure units and one user defined unit allows flexibility when using the CPG2300 Portable Pressure Calibrator. The CPG2300 Portable Presssure Calibrator can have one or two independent precision pressure sensors which can be displayed simultaneously. Channel A can be ordered with full scale ranges up to 6000 psi. Channel B can be ordered with ranges from 3 to 1000 psig or 7.5 to 1000 psia. The user interface is through a monochrome 128 x 64 LCD, with white LED back light. A tactile membrane keypad makes navigation within the intuitive menu easy. Options to display range A and B, or range A or B and the analog measurement channel (mA), plus the ability to power a control loop make the CPG2300 Portable Pressure Calibrator ideal for field calibration of pressure and differential pressure transmitters. Built in functionality to display min/max peak pressure and rate per second per hour and per three hour plus a null function give the CPG2300 Portable Pressure Calibrator additional functionality for trouble shooting process pressure transmitters or monitoring barometric pressure. Single Range: -15 to 2000 psi bi-directional, accuracy 0.015% FS. RS-232. Without multimeter package -15 to 2K PSI Absolute, gauge, bi-directional or vacuum Accuracy: 0.015%FS Dual sensor
-
$3.057
Operating Range: -35 °C 165 °C Accuracy: 0.2 K Stability: /- 0.05 K Display Resolution: 0.01 °C up to 100 °C Tank Dimension: 60 mm x 150 mm deep Interface: RS-485 Power Supply: AC 100 240 V 50 60 Hz
-
$2.390
Temperature Range: Standard 40 °C 225 °C (Fahrenheit available) Accuracy: 0.3 K Stability: /- 0.05 K Unit: °C Display Resolution: 0.01 °C up to 100 °C, then 0.1 °C Insert Liquid: not changeable (standard) Calibration: calibration report 3.1 Tank Dimension: 60 mm x 150 mm deep Interface: RS-485 Power Supply: AC 115 V, 50/60 Hz Power Cord: for USA/Canada, 115 VAC
-
$1.834
These innovative calibrators have been designed for on-site applications as well as for the severe conditions of the naval and marine sectors. Their ease of use and their compact and practical design make them unbeatable in industrial processes where the calibration of the temperature measurement systems is essential for the control of the process and the quality of the final product. Special attention is paid to reduce weight, size and to reinforce robustness by using an aluminium body as well as aluminium and stainless steel for many internal parts. Temp. Range: Amb -24 to 140C, Accuracy /- 0.5 K, AC 115/230V, 50/60Hz (automatically switched) Insert not included, sold separately CTA9I High stability Possibility to check temperature switches Low weight and compact design Simple operation > Each Unit Includes Temperature dry-well calibrator model CTD4000 Power cord, 1.5 m (5 ft) with safety plug For CTD4000-140 3.3 mm, 4.8 mm and 2 x 6.4 mm [0.13 in, 0.19 in and 2 x 0.25 in] For CTD4000-375 3.2 mm, 4.8 mm, 6.4 mm and 11.1 mm [0.13 in, 0.19 in, 0.25 in and 0.44 in] For CTD4000-650 3.2 mm, 5 mm, 7 mm and 10.5 mm [0.13 in, 0.2 in, 0.28 in and 0.41 in] Replacement Tools Operating Instructions
-
$1.278
Operating Range: amb 375 °C Accuracy: 0.5 0.8 K Stability: /- 0.05 K Display Resolution: 0.1 °C Test Piece Insertion Length: 100 mm Interface: RS-232 Power Supply: switchable Scope of delivery: 6.2 mm insert, removal tool, power cord and operating instructions
-
$2.279
Operating Range: 40 °C 450 °C (Fahrenheit available) Accuracy: 0.3 K at 100 °C, 0.5 K at 450 °C Stability: /- 0.05 K at 100 °C, /- 0,1 K at 450 °C Unit: °C Uniformity, axial: <, 0.05 K at 100 °C, <, 0.2 K at 450 °C Display Resolution: 0.01 °C up to 100 °C, then 0.1 °C Protective Conductor: existing in electric circuit Calibration: calibration report 3.1 Test Piece Insertion Length: 150 mm Interface: RS-485 Power Supply: AC 230 V, 50/60 Hz Power Cord: for USA/Canada, 115 VAC
-
$2.279
Operating Range: 40 °C 650 °C (Fahrenheit available) Accuracy: 0.3 K at 100 °C, 0.8 K at 650 °C Stability: /- 0,05 K at 100 °C, /- 0,1 K at 650 °C Unit: °C Uniformity, axial: <, 0.2 K at 100 °C, <, 0.5 K at 650 °C Display Resolution: 0.01 °C up to 100 °C, then 0.1 °C Protective Conductor: existing in electric circuit Calibration: calibration report 3.1 Test Piece Insertion Length: 150 mm Interface: RS-485 Power Supply: AC 100240 V, 5060 Hz Power Cord: for USA/Canada, 115 VAC
-
Sale!
$3.890 Original price was: $3.890.$3.750Current price is: $3.750.
Operating Range: -55°C 200°C (Fahrenheit available) Accuracy: 0.15 K from -55 °C to 100 °C, 0.25 K at 200 °C Stability: /- 0.05 K Unit: °C Uniformity, axial: <, 0.04 K at 200 °C Display Resolution: 0.01 °C up to 100 °C Calibration: calibration report 3.1 Test Piece Insertion Length: 150 mm Interface: RS-485 Power Supply: AC 100 240 V 50 60 Hz Power cord: for USA/Canada, 115 VAC
-
$2.445
Operating Range: -10 °C0 °C100 °C (Fahrenheit available) Accuracy: 0.05 K at 0°C Stability: 0 °C /- 0.01 K Unit: °C Uniformity, axial: <, 0.05 K Display Resolution: 0,1 °C Test Piece Insertion Length: 150 mm Number of Test Holes: 7 with a diameter of 6.5 mm Calibration: calibration report 3.1 Interface: RS-485 Power Supply: AC 100 240 V 50 60 Hz Power Cord: for USA/Canada, 115 VAC