Showing 1–9 of 254 results

  • Extech PQ3120

    $445

    Flex Current Clamp (6 ID) Amp Output (BITE2)

  • Megger 1002-552

    $193

    Lithium-Ion Battery Spare for the DET2/3 Order #: 1002-552 Mfg #: 1002-552

  • Megger 1002-643

    $285

    Set of 3 high voltage leads 5kV insulated clips 10 meters long CAT IV 600V

  • Megger 1006-604

    $2.223

    High or low output power selection for condition diagnosis Rechargeable battery or line power supply, continuous operation, even with dead battery 10 A for 60 seconds, less time waiting to cool, great for charging inductance High input protection to 600 V, inadvertent connection to line or UPS voltage will not blow a fuse Heavy duty case: IP 65 lid closed, IP54 operational (battery operation only) Rotary switch selects one of five test modes, including auto start on connection, giving ease of use Equally at home in the laboratory, the workshop or in the field, on the bench or on the ground, Megger’s new heavy duty DLRO10HD low resistance ohmmeter combines rugged construction with accuracy and ease of use It features an internal rechargeable battery and can also operate from a mains supply, even if the battery is completely flat > Each Unit Includes KC1 kelvin clip 3m leads Test lead pouch (lid mounted) DLRO10HD user guide CD Warranty book

  • Megger 210170

    $825

    These Insulation Resistance Testers are the ideal instruments when high ranges are needed for measuring insulation resistance. Both provide excellent test voltage regulation and an external guard terminal to eliminate surface leakage current from the measurement. Megger Model # 210170 Test Voltages: 100, 250, 500, 1000 VDC Insulation Resistance: 0 to 20,000 Megohms Hand-Cranked, Extremely Stable Test Voltage Guard Terminal Eliminates Surface Leakage Current 7 x 6 x 5 HWD/5 lbs. > Each Unit Includes Six AA Alkaline batteries (XL8190 only) Test lead set (4764E) Carrying case Instructions

  • Megger 210400

    $3.578

    Zero-start, high-voltage interlock Shielded, high-voltage output cable permanently connected to the instrument Redundant grounding connections Easy-to-follow, color-coded meter scales Continuously variable test voltage Rugged field construction Circuit-breaker protection > Each Unit Includes Ground connection cable 10 ft [3 m] 4702Test record card universal 210954Power cord, for Cat. No. 210415 17032 Instruction manual

  • Megger 210415

    $4.702

    The 5- and 15-kV Megohm-meters are high-voltage, line-operated instruments. They provide a continuously variable test voltage for highly sensitive insulation-resistance measurements of all types of electrical equipment and power cable. 15 kV, 300 G-ohms Zero-start, high-voltage interlock Shielded, high-voltage output cable permanently connected to the instrument Redundant grounding connections Easy-to-follow, color-coded meter scales Continuously variable test voltage Rugged field construction Circuit-breaker protection > Each Unit Includes Ground connection cable, 10 ft [3 m] 4702 Test record card, universal 210954 Power cord, for Cat. No. 210415 17032 Instruction manual for 15-kV model AVTM21-415JA

  • Megger 220005

    $2.364

    Dielectric test sets measure leakage current while applying a DC voltage at or above the insulation systems operating level. This measurement aids in determining the insulation systems ability to withstand over voltages such as lightning strikes and switching surges. Reads Leakage Current from 1 to 5,000 Microamps Test Ranges: 0-2.5/0-5 kV DC, Continuously Variable 5 mA Continuous Output Current 10 x 13.5 x 9.5 HWD/20.5 lbs. Compact and portable Air insulated, uses no oil ±2% accuracy Leakage current measurement as low as 0.1 mA Continuously variable test voltage with zero-start safety interlock Fast charging of high-capacitance samples Current guard circuit for highly accurate measurements Strip chart recorder for hard copies (optionally available) Input and output line circuit breaker Output current overload relay Zero-start interlock for high-voltage output > Each Unit Includes Power Cord High Voltage Cable (40586) Ground Cable (4702) Instructions

  • Megger 220015

    $3.163

    Dielectric test sets measure leakage current while applying a dc voltage at or above the insulation systems operating level. This measurement aids in determining the insulation systems ability to withstand over voltages such as lightning strikes and switching surges. Reads Leakage Current from 1 to 5,000 Microamps Test Ranges: 0-2.5/0-5 kV DC, Continuously Variable 5 mA Continuous Output Current 10 x 13.5 x 9.5 HWD/20.5 lbs. Compact and portable Air insulated, uses no oil ±2% accuracy Leakage current measurement as low as 0.1 mA Continuously variable test voltage with zero-start safety interlock Fast charging of high-capacitance samples Current guard circuit for highly accurate measurements Strip chart recorder for hard copies (optionally available) Input and output line circuit breaker Output current overload relay Zero-start interlock for high-voltage output Switch control and indicating lights for high-voltage ON/OFF on the 15-kV model Full circuit breaker protection 15 kV model > Each Unit Includes Power Cord High Voltage Cable (40586) Ground Cable (4702) Instructions