Showing 1–9 of 115 results
-
$169
Hioki Model # 3129 Live wire check (R-S/ S-T only) Bright LED and buzzer indicate phase direction Easy clamping over insulated wires of up to 17mm in diameter Low battery warning and auto power off Voltage Detection: Electrostatic Induction Method Voltage Range: 70V to 600V AC (50/60 Hz) (sine wave, continuous input) Clamp Diameter: 17mm max. of insulated wire Display: Phase Detection: Positive 4 LEDs lit in clockwise order and 3 short beeps, Negative 4 LEDs lit in counter clockwise order and 1 beep, Live wire check: R-S and S-t will light if voltage between wires are within range Battery Check: On lamp blinks to indicate battery low status Auto Power Off: Auto shut off if no activity is detected after 15 min Power Supply: Two “AA” batteries continuous use approx. 70 hours Operating Temp: 32-104 degrees F 80%RH Storage Temp: -4 to 140 degrees F 80%RH Standards: Cat III 600V
-
$3.052
Insulation and AC/DC continuous voltage withstand testing Safety standards compliance testing Stores up to 10 sets of test conditions (10 each for insulation and voltage withstand) Zero-V Switching (voltage withstand testing) Electrical Discharge function (DC voltage withstand, insulation testing) Automated testing support Interlock Protect function Remote controllable > Each Unit Includes 1 9615 H.V. Test Lead, High voltage side 1 9615 H.V. Test Lead, Return 1 Power cord 1 Spare fuse
-
$1.692
Measurement items Low resistance, AC 4-terminal method Generator section Current generator principle: PWM constant current control, Current setting range: 3.0 A to 31.0 A (0.1 A resolution), into 0.1 Ohm load, Maximum output power: 130 VA*1 (at output terminals) *1 Subject to derating according to ambient temperature (80 % at 40 °C) Frequency: 50 Hz or 60 Hz sine wave, Soft start function: Apply current only after checking load connection Monitor section Resistance measurement: 0 to 1.800 Ohm (0.001 Ohm resolution), Accuracy: ±2 % rdg. ±4 dgt. (after zero-adjust), Current monitoring range: 0 to 35.0 A AC (0.1 A resolution), Monitoring cycle: 2 times/second Other functions Timer setting: Counts down time after start until preset time, or shows elapsed time after start, Setting range: 0.5 to 999 second, Comparator: Pass/Fail evaluation using preset upper/lower limit, I/O output, Memory function: max. 20 settings (with save/load) Display Fluorescent tube digital display Power supply 100 to 120 V, 200 to 240 V AC (auto-switching), 50/60 Hz Dimensions, mass 320 mm(12.60 in)W × 90 mm(3.54 in)H × 263 mm(10.35 in)D, 7 kg (246.9 oz) > Each Unit Includes Power cord Spare fuse Shorting bar(2)
-
$1.692
3159-01 Insulation/ Withstanding Tester (120VAC) Perform insulation resistance and withstand voltage testing in a single series Insulation and voltage withstand testing Safety standards compliance testing Stores up to 10 sets of test conditions (10 each for insulation and voltage withstand) Voltage comparator functions (voltage withstand testing) Zero-V Switching (voltage withstand testing) Electrical Discharge function (insulation testing) Automated testing support Interlock Protect function Remote controllable Power Supply: 120 V AC, 50/60 Hz
-
$1.881
Insulation and voltage withstand testing Safety standards compliance testing Stores up to 10 sets of test conditions (10 each for insulation and voltage withstand) Voltage comparator functions (voltage withstand testing) Zero-V Switching (voltage withstand testing) Electrical Discharge function (insulation testing) Automated testing support Interlock Protect function Remote controllable
-
$1.889
Hioki Model# 3169-20-01/5000 Measure up to two 3-phase, 3-wire systems (displays voltage and current for three lines) Measure up to four single-phase, 2-wire systems 5 A to 5000 A range Compact and light weight PC card data storage Power recording for individual waveforms Simultaneous recording of demand values and harmonics Basic Accuracy: Voltage: ±0.2 % rdg. ±0.1 % f.s., Current:±0.2 % rdg. ±0.1 % f.s. Clamp accuracy (active power, at 45 to 66 Hz) Measurement Ranges: Voltage: 150 V to 600 V, 3 ranges, Current: 5 A to 5 kA, 8 ranges (use clamp sensor), Power: 750 W to 9 MW, 16 combination patterns Data storage Internal memory: 1 MB, Flash Card: Up to 528 MB Power supply 100 to 240 V AC, 50/60 Hz Dimensions: 210 mm(8.27 in)W × 160 mm(6.30 in)H × 60 mm(2.36 in)D, 1.2 kg (42.3 oz) > Each Unit Includes 3169-20 Power quality analyzer 9661 CT 500A clamps 9667 (3) 5000A Clamps 3169 Hard Case Software 32MB Flash Card
-
$1.206
Simultaneously measure demand and harmonic waveforms that share the same voltage line over 4-circuits Data can be saved onto a PC card High-speed and continuous processing to measure individual waveforms Measurement line & number of circuits Single-phase 2-wires (4 circuits), Single-phase 3-wires (2 circuits), Three-phases 3-wires (2 or 1 circuit), and Three-phases 4-wires (1 circuit) Note: 50 or 60 Hz, and that share the same voltage line Measurement items Voltage, Current, Active/ reactive/ apparent power, Active/ reactive power integration, Power factor, Frequency, Harmonic waveform value Voltage ranges 150.00 V to 600.00 V AC, 3 ranges Current ranges 500.00 mA to 5.0000 kA AC (depends on current sensor in use) Power ranges 75.000 W to 900.00 kW (depends on combination of voltage, current range, and measurement line) Basic accuracy AC Voltage: ±0.2 % rdg. ±0.1 % f.s. AC Current: ±0.2 % rdg. ±0.1 % f.s. current sensor accuracy Active power: ±0.2 % rdg. ±0.1 % f.s. current sensor accuracy (at power factor = 1) CLAMP ON SENSOR 9661: ±0.3 % rdg. ±0.01 % f.s. (different from each model) Measurement method Digital sampling, PLL synchronization or 50/60 Hz fixed clock Basic accuracy Active power: ±0.2% rdg. ±0.1% f.s. clamp-on sensor accuracy (at 45 to 66 Hz) Display refresh rate 2 times /sec (except when using a PC card while accessing the internal memory, or when performing RS-232C communications) Data save interval Standard interval: 1 sec to 30 sec, 1 minute to 60 minutes, 13 selects Fast interval: A single waveform, or 0.1, 0.2, or 0.5 sec (at instant value only) Frequency characterristics Fundamental waveforms up to the 50th order ±3% f.s. measurement accuracy (of a 45 to 66 Hz fundamental waveform) Other functions Error connect check, language selection, display hold, setting backup, power shut off management, key lock, [3169-21 only] D/A output 4 channels, ±5 V DC f.s.) Power supply 100 to 240 V AC, 50/60 Hz, 30 VA max. Dimensions, mass 210 mm (8.27 in) W × 160 mm (6.30 in) H × 60 mm (2.36 in) D, 1.2 kg (42.3 oz) > Each Unit Includes VOLTAGE CORD L9438-53 (Black/ Red/ Yellow/ Blue) Power cord Instruction Manual Quick Start Manual CD-R (RS-232C interface operating manual) Input cord label
-
$1.868
Measure up to 3-phase, 3-wire system (displays voltage and current for three lines) Measure up to four single-phase, 2-wire systems 5A to 5000A range Compact and light weight PC card data storage Power recording for individual waveforms Simultaneous recording of demand values and harmonics > Each Unit Includes 4ea. 9660 CT (100amp) 9438-03 Voltage Cables Molded Carrying Case Power Cord 9625 PC Software 256MB Compact Flash Card
-
$1.923
Measure up to two 3-phase, 3-wire systems (displays voltage and current for three lines) Measure up to four single-phase, 2-wire systems 5 A to 5000 A range Compact and light weight PC card data storage Power recording for individual waveforms Simultaneous recording of demand values and harmonics Basic Accuracy: Voltage: ±0.2 % rdg. ±0.1 % f.s., Current:±0.2 % rdg. ±0.1 % f.s. Clamp accuracy (active power, at 45 to 66 Hz) Measurement Ranges: Voltage: 150 V to 600 V, 3 ranges, Current: 5 A to 5 kA, 8 ranges (use clamp sensor), Power: 750 W to 9 MW, 16 combination patterns Data storage Internal memory: 1 MB, Flash Card: Up to 528 MB Power supply 100 to 240 V AC, 50/60 Hz Dimensions: 210 mm(8.27 in)W × 160 mm(6.30 in)H × 60 mm(2.36 in)D, 1.2 kg (42.3 oz) > Each Unit Includes 9438-03 voltage cord set (1 cord each of black, red, yellow, and blue) Voltage cord Ground adapter (3P to 2P) Input cord label Operating manuals (Advanced edition and Quick Start Guide) CD-R (Advanced edition and RS-232C interface operating manuals) 9441 connection cable