Showing 10–18 of 53 results

  • Compliance West HT-2800S

    $825

    High precision leakage current, duration and ground continuity settings. Allows no load setup of leakage current and test dwell times. Once entered, ground continuity setting, leakage current and test dwell times can be referenced on the front panel display when unit is not testing. Leakage currents can be set from 1-5 mA DC in 0.1mA increments. Dwell times can be set from 1-60 seconds in 1 second increments. Two tests with one setup. Conducts UL/CSA Ground continuity and Hipot tests with one setup, so no additional equipment is needed. Small and light. 9.25 wide x 4.75 high x 10 deep. 11 lbs. But rugged enough to test manufactured housing. Ground continuity check is defeatable for testing two-wire products. Easy equipment connections. Plug your equipment right into the NEMA plug on the front panel. No adapters needed! J2 and J3 cords allow connection of pigtail power leads. Simple test outcome judgement. Green lights mean pass red lights mean fail. Failing tests sound a buzzer as well. Ready for your UL Inspector out of the box. NIST Traceable Calibration Certificate to MIL-STD45662-A is included. Cal cert is in accordance with UL guidance. Operation Instructions are printed on the rear panel for easy reference. In-depth testing. Both true Arc Detection and Leakage Current circuits test the product to find problems. RED lights and a buzzer leave no question if a failure has occurred. Expandable for TUV/European Agency Testing. Can be connected to our GF-30ac 25A Ground Bond Tester with optional TEST-LINK™. Easy shift-by-shift Function Test. Compatible with our Patented function checker, the HTT-1and HTT-1R (With 0.1 ohm Ground check Pass/Fail Setup).

  • Compliance West HT-3000S

    $1.034

    High precision leakage current, duration and ground continuity settings. Allows no load setup of leakage current and test dwell times. Once entered, ground continuity setting, leakage current and test dwell times can be referenced on the front panel display when unit is not testing. Leakage currents can be set from 1-20 mA AC or 1-5 mA DC in 0.1mA increments. Dwell times can be set from 1-60 seconds in 1 second increments. Two tests with one setup. Conducts UL/CSA Ground continuity and Hipot tests with one setup, so no additional equipment is needed. Small and light. 9.25 wide x 4.75 high x 10 deep. 11 lbs. But rugged enough to test manufactured housing. Ground continuity check is defeatable for testing two-wire products. Easy equipment connections. Plug your equipment right into the NEMA plug on the front panel. No adapters needed! J2 and J3 cords allow connection of pigtail power leads. Simple test outcome judgement. Green lights mean pass red lights mean fail. Failing tests sound a buzzer as well. Ready for your UL Inspector out of the box. NIST Traceable Calibration Certificate to MIL-STD45662-A is included. Cal cert is in accordance with UL guidance. Operation Instructions are printed on the rear panel for easy reference. In-depth testing. Both true Arc Dectection and Leakage Current circuits test the product to find problems. RED lights and a buzzer leave no question if a failure has occurred. Expandable for TUV/European Agency Testing. Can be connected to our GF-30ac 25A Ground Bond Tester with optional TEST-LINK™. Easy shift-by-shift Function Test. Compatible with our Patented function checker, the HTT-1and HTT-1R (With 0.1 ohm Ground check Pass/Fail Setup).

  • Compliance West HT-3500S-RF

    $1.436

    High precision leakage current, duration and ground continuity settings. Allows no load setup of leakage current and test dwell times. Once entered, ground continuity setting, leakage current and test dwell times can be referenced on the front panel display when unit is not testing. Leakage currents can be set from 1-20 mA AC or 1-5 mA DC in 0.1mA increments. Dwell times can be set from 1-60 seconds in 1 second increments. Two tests with one setup. Conducts UL/CSA Ground continuity and Hipot tests with one setup, so no additional equipment is needed. Small and light. 9.25 wide x 4.75 high x 10 deep. 14 lbs. But rugged enough to test manufactured housing. Ground continuity check is defeatable for testing two-wire products. Easy equipment connections. Plug your equipment right into the NEMA plug on the front panel. No adapters needed! J2 and J3 cords allow connection of pigtail power leads. Simple test outcome judgement. Green lights mean pass red lights mean fail. Failing tests sound a buzzer as well. Ready for your UL Inspector out of the box. NIST Traceable Calibration Certificate to MIL-STD45662-A is included. Cal cert is in accordance with UL guidance. Operation Instructions are printed on the rear panel for easy reference. In-depth testing. Both true Arc Dectection and Leakage Current circuits test the product to find problems. RED lights and a buzzer leave no question if a failure has occurred. Expandable for TUV/European Agency Testing. Can be connected to our GF-30ac 25A Ground Bond Tester with optional TEST-LINK™. Easy shift-by-shift Function Test. Compatible with our Patented function checker, the HTT-1and HTT-1R (With 0.1 ohm Ground check Pass/Fail Setup).

  • Compliance West HT-4200S

    $1.102

    High precision leakage current, duration and ground continuity settings. Allows no load setup of leakage current and test dwell times. Once entered, ground continuity setting, leakage current and test dwell times can be referenced on the front panel display when unit is not testing. Leakage currents can be set from 1-20 mA AC or 1-5 mA DC in 0.1mA increments. Dwell times can be set from 1-60 seconds in 1 second increments. Two tests with one setup. Conducts UL/CSA Ground continuity and Hipot tests with one setup, so no additional equipment is needed. Small and light. 9.25 wide x 4.75 high x 10 deep. 11 lbs. But rugged enough to test manufactured housing. Ground continuity check is defeatable for testing two-wire products. Simple test outcome judgement. Green lights mean pass red lights mean fail. Failing tests sound a buzzer as well. Ready for your UL Inspector out of the box. NIST Traceable Calibration Certificate to MIL-STD45662-A is included. Cal cert is in accordance with UL guidance. Operation Instructions are printed on the rear panel for easy reference. In-depth testing. Both true Arc Dectection and Leakage Current circuits test the product to find problems. RED lights and a buzzer leave no question if a failure has occurred. Expandable for TUV/European Agency Testing. Can be connected to our GF-30ac 25A Ground Bond Tester with optional TEST-LINK™. Easy shift-by-shift Function Test. Compatible with our Patented function checker, the HTT-1and HTT-1R (With 0.1 ohm Ground check Pass/Fail Setup).

  • Compliance West HT-5000P-AC-200MA

    $4.223

    The HT-5000P ac 200mA is a special use AC only hipot tester, can deliver up to 200 mA, with voltage output from 0 to 5000 VAC. The leakage current can be set from 5 200 mA in 1 mA increments in the front panel. One year warranty, calibration certificate to ANSI Z540 included. Made in the USA. Features Leakage current up to 200 mA. Microcontroller technologies, one button test, easy to setup, LEDs indicates test in progress. Upon failures buzzer sounds and testing is terminated. Output voltage, Leakage current and test duration are controlled in the front panel. Zero voltage start included. One year calibration cycle. Main shutdown switch in front panel for safety.

  • Compliance West HT-5000P-AC-DC-200MA

    $7.447

    A 5000V AC/ 6000VDC hipot tester thats easy to use and priced right. Select AC or DC output via front panel button. Simple for production line personnel, easy to set up. Designed so that operator can defeat the leakage current limit and dielectric breakdown shutoffs to allow troubleshooting and analysis of problems with the DUT. Includes precision leakage current and test time setup and viewing from the LED meter. Adjustment is made with no HV output. Made in the USA. Features AC output: up to 5,000 V. DC output: up to 7,000 V. Microcontroller Technology, one button test, easy to setup, LEDs indicate test progress. Upon failure, buzzer sounds and testing is terminated. Output voltage, leakage current limit and test duration are controlled from the front panel. Arc detection and test timer are defeatable. Separate arc detection circuitry. Main shutdown switch on front panel for safety.

  • Compliance West HT-5000P-V2

    $1.128

    The Compliance West HT-5000P V2 Hipot Tester has a AC ouput range up to 5,000 V and a DC output range up to 6,000 V. The HT-5000P V2 is easy to setup and uses microcontroller technology and has one button test. The Compliance West HT-5000P V2 Hipot Tester has a rugged design with easy-to-use Microcontroller Technology, this AC/DC hipot tests to 5,000Vac @ 10mA and 6,000Vdc @ 5mA. Tested to withstand a 6 drop test with no damage. AC output: up to 5,000 V DC output: up to 6,000 V Microcontroller Technology, one button test, easy to setup LED/s indicate test progress. Upon failure, buzzer sounds and testing is terminated Leakage current limit, voltage ramp-up time and test duration are controlled from the rear panel

  • Compliance West HTT-1R

    $243

    Function Tester Gd Pass 0.025 Lk Pass 220k Arcover 750V Order #: HTT-1R Mfg #: HTT-1R

  • Compliance West HTT-1R-CUSTOM

    $359

    The HTT-1R Custom simulates the following failures: Ground Continuity Chassis to Ground (0.01ohm), and/or High Leakage Line to Ground (Custom ohm), and/or Dielectric Withstand Failure (Arc View window displays an arc at 750Vac ± 400V). The HTT-1R can also be set to simulate passing tests: Ground Continuity Chassis to Ground (0.025 ohm), and/or Normal Leakage Line to Ground (Custom ohm), and /or Dielectric Withstand OK (up to 3000 volts) Arc Testing is at 750 ± 400Vac. Results visible through Front Panel Window. Works with any manufacturers Dielectric Withstand or Ground Continuity Tester. The HTT-1R simulates the failures and your tester should return results consistent with the switch settings on the front panel of the HTT-1R The HTT-1R is a passive device. No batteries or power is required. Verifies proper operation of your equipment in less than a minute. Portable. Light weight. Simple to operate. Saves time. For testing of Ground Bond Testers up to 30A.. 1 year warranty.